Estimation of skin microcirculatory hemoglobin oxygen saturation and red blood cell tissue fraction using a multispectral snapshot imaging system: a validation study

Abstract. Significance: Hemoglobin oxygen saturation and red blood cell (RBC) tissue fraction are important parameters when assessing microvascular status. Functional information can be attained using temporally resolved measurements performed during stimulus–response protocols. Pointwise assessments can currently be conducted with probe-based systems. However, snapshot multispectral imaging (MSI) can be used for spatial–temporal measurements. Aim: To validate if hemoglobin oxygen saturation and RBC tissue fraction can be quantified using a snapshot MSI system and an inverse Monte Carlo algorithm. Approach: Skin tissue measurements from the MSI system were compared to those from a validated probe-based system during arterial and venous occlusion provocation on 24 subjects in the wavelength interval 450 to 650 nm, to evaluate a wide range of hemoglobin oxygen saturation and RBC tissue fraction levels. Results: Arterial occlusion results show a mean linear regression R2  =  0.958 for hemoglobin oxygen saturation. Comparing relative RBC tissue fraction during venous occlusion results in R2  =  0.925. The MSI system shows larger dynamic changes than the reference system, which might be explained by a deeper sampling including more capacitance vessels. Conclusions: The snapshot MSI system estimates hemoglobin oxygen saturation and RBC tissue fraction in skin microcirculation showing a high correlation (R2  >  0.9 in most subjects) with those measured by the reference method.

[1]  E. Kviesis-Kipge,et al.  Snapshot hyperspectral system for noninvasive skin blood oxygen saturation monitoring , 2018, Photonics Europe.

[2]  D. Altman,et al.  Applying the right statistics: analyses of measurement studies , 2003, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[3]  M. Roustit,et al.  Non‐invasive Assessment of Skin Microvascular Function in Humans: An Insight Into Methods , 2012, Microcirculation.

[4]  Asgeir Bjorgan,et al.  Estimation of skin optical parameters for real-time hyperspectral imaging applications , 2014, Journal of biomedical optics.

[5]  Ingemar Fredriksson,et al.  Quantitative Laser Doppler Flowmetry , 2009 .

[6]  D. Low,et al.  Historical reviews of the assessment of human cardiovascular function: interrogation and understanding of the control of skin blood flow , 2019, European Journal of Applied Physiology.

[7]  Daniel Chappell,et al.  Regulation of blood flow and volume exchange across the microcirculation , 2016, Critical Care.

[8]  Ingemar Fredriksson,et al.  Oxygen saturation, red blood cell tissue fraction and speed resolved perfusion - A new optical method for microcirculatory assessment. , 2015, Microvascular research.

[9]  Andy Lambrechts,et al.  A compact snapshot multispectral imager with a monolithically integrated per-pixel filter mosaic , 2014, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[10]  Oleg Burdakov,et al.  Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry , 2013, Journal of biomedical optics.

[11]  Marcus Larsson,et al.  Spatial and temporal skin blood volume and saturation estimation using a multispectral snapshot imaging camera , 2017, BiOS.

[12]  Tomas Strömberg,et al.  Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols. , 2017, Microvascular research.

[13]  Walter J. Riker A Review of J , 2010 .

[14]  F. Mériaudeau,et al.  Subcutaneous veins depth measurement using diffuse reflectance images. , 2017, Optics express.

[15]  Jon Yngve Hardeberg,et al.  A Spectral Filter Array Camera for Clinical Monitoring and Diagnosis: Proof of Concept for Skin Oxygenation Imaging , 2019, J. Imaging.

[16]  Jon Yngve Hardeberg,et al.  An Evaluation Framework for Spectral Filter Array Cameras to Optimize Skin Diagnosis , 2019, Sensors.

[17]  S. Jacques Optical properties of biological tissues: a review , 2013, Physics in medicine and biology.

[18]  Ingemar Fredriksson,et al.  In vivo characterization of light scattering properties of human skin in the 475- to 850-nm wavelength range in a Swedish cohort , 2018, Journal of biomedical optics.

[19]  Simon Hyttel-Sorensen,et al.  A comparison between two NIRS oximeters (INVOS, OxyPrem) using measurement on the arm of adults and head of infants after caesarean section. , 2014, Biomedical optics express.

[20]  Anthony J. Durkin,et al.  Evaluation of a pointwise microcirculation assessment method using liquid and multilayered tissue simulating phantoms , 2017, Journal of biomedical optics.

[21]  Liang Gao,et al.  A review of snapshot multidimensional optical imaging: measuring photon tags in parallel. , 2016, Physics reports.

[22]  Guolan Lu,et al.  Medical hyperspectral imaging: a review , 2014, Journal of biomedical optics.

[23]  Thomas B Willingham,et al.  Measuring reactive hyperemia in the lower limb using near-infrared spectroscopy , 2016, Journal of biomedical optics.

[24]  Michael W. Kudenov,et al.  Review of snapshot spectral imaging technologies , 2013, Optics and Precision Engineering.

[25]  Uldis Rubins,et al.  Multimodal Device for Real-Time Monitoring of Skin Oxygen Saturation and Microcirculation Function , 2019, Biosensors.

[26]  Marcus Larsson,et al.  Estimating skin blood saturation by selecting a subset of hyperspectral imaging data , 2015, Photonics West - Biomedical Optics.

[27]  Quan Liu,et al.  Review of Monte Carlo modeling of light transport in tissues , 2013, Journal of biomedical optics.

[28]  M. Nelson,et al.  Reactive Hyperemia: A review of methods, mechanisms, and considerations. , 2020, American journal of physiology. Regulatory, integrative and comparative physiology.