The need for phase‐encoding flow compensation in high‐resolution intracranial magnetic resonance angiography

To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high‐resolution time‐of‐flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross‐hatch—appearing artifact in surrounding tissue.

[1]  Eun-Kee Jeong,et al.  Reduction of flow‐related signal loss in flow‐compensated 3D TOF MR angiography, using variable echo time (3D TOF‐VTE) , 2002, Magnetic resonance in medicine.

[2]  J Hale,et al.  Applications of voxel shifting in magnetic resonance imaging. , 1990, Investigative radiology.

[3]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[4]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[5]  D. Parker,et al.  The Voxel Sensitivity Function in Fourier Transform Imaging: Applications to Magnetic Resonance Angiography , 1995, Magnetic resonance in medicine.

[6]  Yiping P. Du,et al.  Abbreviated moment‐compensated phase encoding , 1995, Magnetic resonance in medicine.

[7]  D L Parker,et al.  A three‐coil comparison for MR angiography , 2000, Journal of magnetic resonance imaging : JMRI.

[8]  A. Crawley,et al.  Elimination of oblique flow artifacts in magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[9]  Experiments for two MR imaging theories of motion phase sensitivity. , 1991, Radiology.

[10]  D L Parker,et al.  The application of magnetization transfer to MR angiography with reduced total power , 1995, Magnetic resonance in medicine.

[11]  D G Nishimura,et al.  On the nature and reduction of the displacement artifact in flow images , 1991, Magnetic resonance in medicine.

[12]  R L Ehman,et al.  Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance. , 1990, AJNR. American journal of neuroradiology.

[13]  R. Buxton,et al.  Distortions from curved flow in magnetic resonance imaging , 1993, Magnetic resonance in medicine.

[14]  N J Pelc,et al.  Volume MR angiography: methods to achieve very short echo times. , 1990, Radiology.

[15]  R L Ehman,et al.  Altered phase‐encoding order for reduced sensitivity to motion in three‐dimensional MR imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[16]  S J Riederer,et al.  Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath‐hold three‐dimensional gradient echo imaging , 1997, Magnetic resonance in medicine.

[17]  P. R. Moran 4654591 NMR flow imaging using bi-phasic excitation field gradients , 1987 .