Grid-Forming Inverters: A Critical Asset for the Power Grid

Increasing inverter-based sources reduces the system’s inertia resulting in possible frequency stability issues. Understanding low-inertia systems and their stability properties is of crucial importance. This article introduces fundamental ways to integrate high levels of renewable energy (RE) and distributed energy resources (DERs) in the power system while creating a more flexible power system. Using RE and DER in the distribution system has many advantages such as reducing the physical and electrical distance between generation and loads, bringing sources closer to loads contributes to the enhancement of the voltage profile, reduction in distribution and transmission bottlenecks, improved reliability, lower losses, and enhances the potential use of waste heat. A basic issue for high penetration of DER is the technical complexity of controlling hundreds of thousands to millions of inverters. This is addressed through autonomous techniques using local measurements eliminating the need for fast control systems. The key issues addressed in this article include using inverter damping to stabilize frequency in systems with low or no inertia, autonomous operation, methods for relieving inverter overload, energy reserves, and their implementation in photovoltaics (PV) systems. This article provides important insight into the interactions between inverter bases sources and the high-power system. The distinction between grid-forming (GFM) inverter and grid-following (GFL) inverter is profound. GFM inverters provide damping to frequency swings in a mixed system, while GFL inverter can aggravate frequency problems with increased penetration. Rather than acting as a source of inertia, the GFM inverter acts as a source of damping to the system. On the other hand, the application of inverters in the power system has two major issues. One is the complexity of controlling hundreds of thousands to millions of inverters. This is addressed through autonomous techniques using local measurements. The other is the potential of high overcurrent in GFM inverters and techniques for explicitly protecting against overloading. To exploit the innate damping of GFM inverters, energy reserves are critical.

[1]  Thomas M. Jahns,et al.  Active Power Reserve Control for Grid-Forming PV Sources in Microgrids using Model-based Maximum Power Point Estimation , 2019, 2019 IEEE Energy Conversion Congress and Exposition (ECCE).

[2]  Ross Baldick,et al.  Integration of Large-Scale Renewable Energy into Bulk Power Systems , 2017 .

[3]  Amrit S. Khalsa,et al.  Survivability of Autonomous Microgrid During Overload Events , 2019, IEEE Transactions on Smart Grid.

[4]  Vahan Gevorgian,et al.  Impact of Frequency-Watt Control on the Dynamics of a High DER Penetration Power System , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[5]  Mohamed E. Elkhatib,et al.  Evaluation of Inverter-based Grid Frequency Support using Frequency-Watt and Grid-Forming PV Inverters , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[6]  T. M. Jahns,et al.  Comparison of Grid Following and Grid Forming Control for a High Inverter Penetration Power System , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[7]  William A. Beckman,et al.  Improvement and validation of a model for photovoltaic array performance , 2006 .

[8]  Dezso Sera,et al.  Frequency Support Functions in Large PV Power Plants With Active Power Reserves , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[9]  Joe H. Chow,et al.  Power System Dynamics and Stability: With Synchrophasor Measurement and Power System Toolbox 2e: With Synchrophasor Measurement and Power System Toolbox , 2017 .

[10]  Dick Duffey,et al.  Power Generation , 1932, Transactions of the American Institute of Electrical Engineers.

[11]  Philip G. Hill,et al.  Power generation , 1927, Journal of the A.I.E.E..

[12]  Vijay Vittal,et al.  Paving the Way: A Future Without Inertia Is Closer Than You Think , 2017, IEEE Power and Energy Magazine.

[13]  Efstratios I. Batzelis,et al.  Power Reserves Control for PV Systems With Real-Time MPP Estimation via Curve Fitting , 2017, IEEE Transactions on Sustainable Energy.

[14]  R H Lasseter,et al.  CERTS Microgrid Laboratory Test Bed , 2011, IEEE Transactions on Power Delivery.

[15]  Wei Du,et al.  Voltage-Source Control of PV Inverter in a CERTS Microgrid , 2014, IEEE Transactions on Power Delivery.

[16]  T. M. Jahns,et al.  Reduced-order harmonic modeling and analysis of droop-controlled distributed generation networks , 2016, 2016 IEEE 7th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[17]  Jon Are Suul,et al.  Equivalence of Virtual Synchronous Machines and Frequency-Droops for Converter-Based MicroGrids , 2014, IEEE Transactions on Smart Grid.

[18]  Robert H. Lasseter,et al.  Overload mitigation control of droop-controlled grid-forming sources in a microgrid , 2017, 2017 IEEE Power & Energy Society General Meeting.

[19]  Joe H. Chow,et al.  Power System Coherency and Model Reduction , 2019, Power System Modeling, Computation, and Control.

[20]  Moshe Sitbon,et al.  Solar Irradiation Independent Expression for Photovoltaic Generator Maximum Power Line , 2017, IEEE Journal of Photovoltaics.

[21]  Pengwei Du,et al.  Wind Integration in ERCOT , 2017 .