Modeling and Analysis Guidelines for Slow Transients — Part III : The Study of Ferroresonance Slow Transients Task Force of the IEEE Working Group on Modeling and Analysis of Systems Transients Using Digital Programs

The ability to predict or confirm ferroresonance depends primarily on the correctness of the transformer model used by the computer simulation. Ferroresonance is introduced and a general modeling approach is given. An overview of available literature and contributors to this area is provided. A simple case of ferroresonance in a single phase transformer is used to illustrate this “phenomenon.” Three phase transformer core structures are discussed. Ferroresonance in three phase grounded-wye distribution systems is described and illustrated with waveform data obtained from laboratory simulations. Representation of the study zone is discussed, modeling techniques are presented, and implementation suggestions are made. Three case studies are presented. Transformer representation is critical to performing a valid simulation. The direction of ongoing research is discussed, and the reader is advised to monitor the literature for ongoing rapid improvements in transformer modeling techniques.

[1]  Bruce Andrew Mork Ferroresonance and Chaos: Observation and Simulation of Ferroresonance in a Five-Legged Core Distribution Transformer , 1992 .

[2]  A. Narang,et al.  Topology based magnetic model for steady-state and transient studies for three-phase core type transformers , 1994 .

[3]  R. J. Rusch,et al.  Wyes and wye nots of three-phase distribution transformer connections , 1989, Papers Presented at the 33rd Annual Conference Rural Electric Power Conference.

[4]  C. Hayashi,et al.  Nonlinear oscillations in physical systems , 1987 .

[5]  E. C. Cherry The Duality between Interlinked Electric and Magnetic Circuits and the Formation of Transformer Equivalent Circuits , 1949 .

[6]  Rheinhold Rudenberg,et al.  Transient Performance of Electric Power Systems: Phenomena in Lumped Networks , 1969 .

[7]  D. D. Mairs,et al.  Overvoltages on five legged core transformers on rural electric systems , 1988 .

[8]  A. S. Morched,et al.  Frequency dependent eddy current models for nonlinear iron cores , 1993 .

[9]  R. G. Andrei,et al.  Voltage Transformer Ferroresonance from an Energy Transfer Standpoint , 1989, IEEE Power Engineering Review.

[10]  F. Robert Bergseth,et al.  Introduction to Electric Energy Devices , 1987 .

[11]  Leander W. Matsch Electromagnetic and electromechanical machines , 1977 .

[12]  D. L. Stuehm,et al.  Application of nonlinear dynamics and chaos to ferroresonance in distribution systems , 1994 .

[13]  D.R. Smith,et al.  Overvoltages with remotely-switched cable-fed grounded wye-wye transformers , 1975, IEEE Transactions on Power Apparatus and Systems.

[14]  D. Jiles,et al.  Theory of ferromagnetic hysteresis , 1986 .

[15]  Egon Brenner Subharmonic response of the ferroresonant circuit with coil hysteresis , 1956, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[16]  J. Lewis Blackburn,et al.  Protective Relaying: Principles And Applications , 2006 .

[17]  R. H. Hopkinson Ferroresonance During Single-Phase Switching of 3-Phase Distribution Transformer Banks , 1965 .

[18]  G. R. Slemon,et al.  Equivalent circuits for transformers and machines including non-linear effects , 1953 .

[19]  Bruce A. Mork,et al.  Five-legged wound-core transformer model: derivation, parameters, implementation and evaluation , 1999 .

[20]  D Millett Ramon,et al.  The assessment and mitigation study of ferroresonance on grounded wye grounded wye three phase padmounted transformers. , 1987 .

[21]  C. Kieny Application of the bifurcation theory in studying and understanding the global behavior of a ferroresonant electric power circuit , 1991 .

[22]  J. Thompson,et al.  Nonlinear Dynamics and Chaos: Geometrical Methods for Engineers and Scientists , 1986 .

[23]  Donald G. Fink,et al.  Standard Handbook for Electrical Engineers , 1978 .

[24]  C. Concordia,et al.  Analysis of series capacitor application problems , 1937, Electrical Engineering.

[25]  A. R. Standard Handbook for Electrical Engineers , 1923, Nature.

[26]  雨谷 昭弘 Alternative transients program rule book , 1989 .

[27]  C.M. Arturi Transient Simulation and Analysis of Three-Phase Five-Limb Step-Up Transformer Following an Out-of-Phase Synchronization , 1991, IEEE Power Engineering Review.

[28]  Bruce A. Mork,et al.  Five-Legged Core Transformer Equivalent Circuit , 1989, IEEE Power Engineering Review.

[29]  H. W. Dommel,et al.  On modelling iron core nonlinearities , 1993 .

[30]  R. A. Walling,et al.  Ferroresonant overvoltages in grounded wye-wye padmount transformers with low-loss silicon steel cores , 1993 .

[31]  G. W. Swift Power Transformer Core Behavior Under Transient Conditions , 1971 .