Variable flow Doppler for hemodialysis access evaluation: theory and clinical feasibility.

Access thrombosis remains an enormous problem for patients on hemodialysis. Current evidence suggests that decreasing access blood flow rate is an important predictor of future access thrombosis and failure. This article describes a method for determining access volume flow and detecting access pathology. The Doppler ultrasound signal downstream from the arterial needle as a function of the variable hemodialysis blood pump flow rate, is used to determine access blood flow. By using this variable flow (VF) Doppler technique compared with duplex volume flow estimates measured in 18 accesses (16 patients with 12 polytetrafluorethylene [PTFE] grafts and 6 autogenous fistulas), the results showed a correlation of 0.83 (p < 0.0001) between these methods. In grafts with lower blood flow rates, aberrant flow patterns were observed, including stagnant or reversed flow during diastole while forward flow was maintained during systole. When reversed diastolic flow was severe, it was accompanied by access recirculation. In conclusion, we report the theory and clinical feasibility of determining access blood flow by using a VF Doppler technique. Measurements are made without the need to determine the access cross sectional area required for duplex volume flow calculations and without the need to reverse the lines required for various indicator dilution techniques. Important information is also obtained about aberrant flow patterns in patients at risk of access failure.

[1]  N. Levin,et al.  Predictive value of access blood flow in detecting access thrombosis. , 1998, ASAIO journal.

[2]  R M Lindsay,et al.  A Comparison of Methods for the Measurement of Hemodialysis Access Recirculation and Access Blood Flow Rate , 1998, ASAIO journal.

[3]  T. Ikizler,et al.  Predictive measures of vascular access thrombosis: a prospective study. , 1997, Kidney international.

[4]  A. Besarab,et al.  The relationship of recirculation to access blood flow. , 1997, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[5]  W. Mali,et al.  Access flow measurements in hemodialysis patients: in vivo validation of an ultrasound dilution technique. , 1996, Journal of the American Society of Nephrology : JASN.

[6]  N M Krivitski,et al.  Theory and validation of access flow measurement by dilution technique during hemodialysis. , 1995, Kidney international.

[7]  M. Moritz,et al.  Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. , 1995, Kidney international.

[8]  D E Finlay,et al.  Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts. , 1993, Radiographics : a review publication of the Radiological Society of North America, Inc.

[9]  M. Moritz,et al.  Hemodynamics of Failing Dialysis Grafts , 1993, Radiology.

[10]  R. O’Connell,et al.  Forecasting thrombosis of vascular access with Doppler color flow imaging. , 1992, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[11]  J. R. Raymond,et al.  Prevention of hemodialysis fistula thrombosis. Early detection of venous stenoses. , 1989, Kidney international.

[12]  J. Sands,et al.  The role of color-flow Doppler ultrasound in the management of hemodialysis accesses. , 1998, ASAIO journal.

[13]  A. Besarab,et al.  The prevention of access failure: pressure monitoring. , 1998, ASAIO journal.

[14]  T. Depner In-Line Methods , 1998 .

[15]  T. Depner Hemodialysis access--the role of monitoring. In-line methods. , 1998, ASAIO journal.

[16]  A. Compton,et al.  Study of vascular access blood flow by angiodynography. , 1995, American journal of kidney diseases : the official journal of the National Kidney Foundation.