Modeling and analysis of six-phase synchronous generator for stand-alone renewable energy generation

This paper presents a mathematical model of six-phase synchronous generator (SPSG) for analysis of its transient and dynamic behavior for stand-alone renewable energy generation in conjunction with a hydro power plant. In the analytical model, effect of common mutual leakage reactance between the two three-phase winding sets, and the mutual leakage coupling between d- and q-axis of the two stator windings have been considered. Paper also discusses the applicability of SPSG for supplying two individual loads by presenting the results of analytical and experimental study of transient and steady-state behavior under various operating conditions. It is shown that it can be used to supply two independent three-phase loads. While the interaction between the two windings is inevitable and variation of load at one winding set changes the operating conditions at the other winding, the situation is still satisfactory for a wide range of rural resistive loads.

[1]  Mohammad Omar Abdullah,et al.  Review and comparison study of hybrid diesel/solar/hydro/fuel cell energy schemes for a rural ICT Telecenter , 2010 .

[2]  M. R. Aghamohammadi,et al.  Method experience with SSFR test for synchronous generator model identification using Hook-Jeeves optimization method , 2007 .

[3]  Emil Levi,et al.  Multiphase Electric Machines for Variable-Speed Applications , 2008, IEEE Transactions on Industrial Electronics.

[4]  R. Hanna,et al.  The Six-Phhase Generator and Transformer into a Three-Phase Power System , 1983, IEEE Transactions on Power Apparatus and Systems.

[5]  Fotis Stergiopoulos,et al.  The effect of the hysteresis band on power management strategies in a stand-alone power system , 2008 .

[6]  Alberto Tessarolo,et al.  On the Modeling of Commutation Transients in Split-Phase Synchronous Motors Supplied by Multiple Load-Commutated Inverters , 2010, IEEE Transactions on Industrial Electronics.

[7]  Teruo Kataoka,et al.  Steady-State Characteristics of a Current-Source Inverter/Double-Wound Synchronous Machine System for AC Power Supply , 1980, IEEE Transactions on Industry Applications.

[8]  R. F. Schiferl,et al.  Six-Phase Synchronous Machine with ac and dc Stator Connections, Part II: Harmonic Studies and a Proposed Uninterruptible Power Supply Scheme , 1983, IEEE Power Engineering Review.

[9]  E. F. Fuchs,et al.  Analysis of an Alternator with Two Displaced Stator Windings , 1974 .

[10]  Girish Kumar Singh,et al.  Selection of capacitance for self-excited six-phase induction generator for stand-alone renewable energy generation , 2010 .

[11]  Indu R. Pillai,et al.  Renewable energy in India: Status and potential , 2009 .

[12]  Girish Kumar Singh,et al.  Steady-state Modeling and Analysis of Six-phase Self-excited Induction Generator for Renewable Energy Generation , 2009 .

[13]  C. Ong,et al.  Six Phase Synchronous Machine with AC and DC Stator Connections, Part I: Equivalent Circuit Representation and Steady-State Analysis , 1983, IEEE Transactions on Power Apparatus and Systems.

[14]  N. Lior Sustainable energy development: The present (2009) situation and possible paths to the future , 2010 .

[15]  J. Jatskevich,et al.  Impedance characterization of a six-phase synchronous generator-rectifier system using average-value model , 2004, Canadian Conference on Electrical and Computer Engineering 2004 (IEEE Cat. No.04CH37513).

[16]  Girish Kumar Singh,et al.  Performance evaluation of series compensated self-excited six-phase induction generator for stand-alone renewable energy generation , 2010 .

[17]  Girish Kumar Singh,et al.  Multi-phase induction machine drive research—a survey , 2002 .

[18]  Lorenzo Fagiano,et al.  KiteGen : A revolution in wind energy generation , 2009 .

[19]  Girish Kumar Singh Modeling and experimental analysis of a self-excited six-phase induction generator for stand-alone renewable energy generation , 2008 .

[20]  T.A. Lipo,et al.  A simplified model of a nine phase synchronous machine using vector space decomposition , 2009, 2009 IEEE Power Electronics and Machines in Wind Applications.

[21]  Girish Kumar Singh,et al.  A six-phase synchronous generator for stand-alone renewable energy generation: Experimental analysis , 2011 .

[22]  Oleg Wasynczuk,et al.  Analysis and average-value modeling of line-commutated converter-synchronous machine systems , 1993 .

[23]  Soteris A. Kalogirou Energy, environment and development , 2010 .

[24]  Wen-Tien Tsai,et al.  An analysis of power generation from municipal solid waste (MSW) incineration plants in Taiwan , 2010 .