Simulation of variable refrigerant flow air conditioning system in heating mode combined with outdoor air processing unit

Variable refrigerant flow (VRF) air conditioning system has become attractive due to better energy performances than traditional air conditioning systems. However, the shortcoming of no outdoor air (OA) intake has not been solved thoroughly. A new VRF and outdoor air processing unit combined air conditioning system is proposed and simulated. The first obstacle is that there is no well-known simulation tool for VRF unit in heating mode. A VRF model of condenser-number independence is developed and validated first. The combined system is modeled by integrating the individual sub-system or component models into a complete system. The average error of the developed model to predict heating capacity, input power and COP are 7.87%, 12.45% and 6.19% respectively. Finally the combined system is simulated under conditions of the same and different set-points of the air conditioning zones. The combined system could maintain all the zones at their specific set-points within small errors no matter the set-points are the same or different. Moreover, indoor air quality can be ensured. The demand of one air conditioning system possessing independent units serving separate zones in the same building could be met by the combined system.

[1]  Nicolas Kelly,et al.  Analysis of retrofit air source heat pump performance: Results from detailed simulations and compari , 2011 .

[2]  Xianting Li,et al.  Simulation model for complex refrigeration systems based on two-phase fluid network – Part I: Model development , 2008 .

[3]  Tainzhen Hong,et al.  Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems , 2009 .

[4]  V. W. Goldschmidt,et al.  Cyclic characteristics of a typical residential air conditioner-modeling of start-up transients , 1985 .

[5]  S. Iniyan,et al.  Energy conservative building air conditioning system controlled and optimized using fuzzy-genetic algorithm , 2010 .

[6]  Shengwei Wang,et al.  CO 2-Based Occupancy Detection for On-Line Outdoor Air Flow Control , 1998 .

[7]  Ruzhu Wang,et al.  Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus , 2008 .

[8]  S. Iniyan,et al.  Energy efficient fuzzy based combined variable refrigerant volume and variable air volume air conditioning system for buildings , 2010 .

[9]  Xinqiao Jin,et al.  Prediction-based online optimal control of outdoor air of multi-zone VAV air conditioning systems , 2005 .

[10]  Zhimin Du,et al.  Generic simulation model of multi-evaporator variable refrigerant flow air conditioning system for control analysis , 2013 .

[11]  Jianjun Xia,et al.  Experimental analysis of the performances of variable refrigerant flow systems , 2004 .

[12]  Y. Hwang,et al.  Simulation comparison of VAV and VRF air conditioning systems in an existing building for the cooling season , 2009 .

[13]  C Keith Rice,et al.  Multiple-Zone Variable Refrigerant Flow System Modeling and Equipment Performance Mapping , 2012 .

[14]  Farouk Fardoun,et al.  Quasi-Steady State Modeling of an Air Source Heat Pump Water Heater , 2011 .

[15]  Carey J. Simonson,et al.  Effectiveness of energy wheels from transient measurements. Part I: Prediction of effectiveness and uncertainty , 2006 .

[16]  John Allison,et al.  Symbolic modelling and predictive assessment of air source heat pumps , 2013 .

[17]  William Goetzler,et al.  Variable Refrigerant Flow , 2007 .

[18]  William Goetzler Variable Refrigerant Flow Systems , 2007 .

[19]  Sumio Shiochi,et al.  Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions , 2009 .

[20]  Shengwei Wang,et al.  Dynamic simulation of building VAV air-conditioning system and evaluation of EMCS on-line control strategies , 1999 .

[21]  Reinhard Radermacher,et al.  Experimental Evaluation of the Ventilation Effect on the Performance of a VRV System in Cooling Mode—Part I: Experimental Evaluation , 2008 .

[22]  Carey J. Simonson,et al.  Effectiveness of energy wheels from transient measurements: Part II—Results and verification , 2006 .

[23]  Tolga N. Aynur,et al.  Variable refrigerant flow systems: A review , 2010 .

[24]  Shengwei Wang,et al.  Model-based optimal control of VAV air-conditioning system using genetic algorithm , 2000 .

[25]  Chen Wu,et al.  Development of control method and dynamic model for multi-evaporator air conditioners (MEAC) , 2005 .

[26]  Jae-Weon Jeong,et al.  Energy Conservation Benefits of a Dedicated Outdoor Air System with Parallel Sensible Cooling by Ceiling Radiant Panels , 2003 .

[27]  Ruzhu Wang,et al.  Energy simulation in the variable refrigerant flow air-conditioning system under cooling conditions , 2007 .