Quantitative microwave imaging with a 2.45-GHz planar microwave camera

This paper presents microwave tomographic reconstructions of the complex permittivity of lossy dielectric objects immersed in water from experimental multiview near-field data obtained with a 2.35-GHz planar active microwave camera. An iterative reconstruction algorithm based on the Levenberg-Marquardt method was used to solve the nonlinear matrix equation which results when applying a moment method to the electric field integral representation. The effects of uncertainties in experimental parameters such as the exterior medium complex permittivity the imaging system geometry and the incident field at the object location are illustrated by means of reconstructions from synthetic data. It appears that the uncertainties in the incident field have the strongest impact on the reconstructions. A receiver calibration procedure has been implemented and some ways: to access to the incident field at the object location have been assessed.

[1]  P.M. Meaney,et al.  An active microwave imaging system for reconstruction of 2-D electrical property distributions , 1995, IEEE Transactions on Biomedical Engineering.

[2]  P. M. van den Berg,et al.  An extended range‐modified gradient technique for profile inversion , 1993 .

[3]  A. Stogryn,et al.  Equations for Calculating the Dielectric Constant of Saline Water (Correspondence) , 1971 .

[4]  Michel Barlaud,et al.  Conjugate-gradient algorithm with edge-preserving regularization for image reconstruction from Ipswi , 1997 .

[5]  Paul M. Meaney,et al.  A dual mesh scheme for finite element based reconstruction algorithms , 1995, IEEE Trans. Medical Imaging.

[6]  C. Pichot,et al.  Diffraction tomography: contribution to the analysis of some applications in microwaves and ultrasonics , 1988 .

[7]  C. Pichot,et al.  Microwave imaging-complex permittivity reconstruction with a Levenberg-Marquardt method , 1997 .

[8]  M. Pastorino,et al.  On the use of regularization techniques in numerical inverse-scattering solutions for microwave imaging applications , 1995 .

[9]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[10]  T. Habashy,et al.  Simultaneous nonlinear reconstruction of two‐dimensional permittivity and conductivity , 1994 .

[11]  Mark J. Hagmann,et al.  Upper Bound on Cell Size for Moment-Method Solutions , 1977 .

[12]  Michel Barlaud,et al.  Gradient and Newton-Kantorovich Methods for Microwave Tomography , 1997 .

[13]  R J Sheppard,et al.  The dielectric properties of formamide, ethanediol and methanol , 1978 .

[14]  C. Pichot,et al.  Inverse scattering: an iterative numerical method for electromagnetic imaging , 1991 .

[15]  C. Vogel A constrained least squares regularization method for nonlinear ill-posed problems , 1990 .

[16]  Nicholas M. Spyrou,et al.  A critical study of the open-ended coaxial line sensor technique for RF and microwave complex permittivity measurements , 1989 .

[17]  Dominique Lesselier,et al.  On the inverse source method of solving inverse scattering problems , 1994 .

[18]  Weng Cho Chew,et al.  Nonlinear diffraction tomography-the use of inverse scattering for imaging , 1993, Proceedings of 27th Asilomar Conference on Signals, Systems and Computers.

[19]  L. Jofre,et al.  Medical imaging with a microwave tomographic scanner , 1990, IEEE Transactions on Biomedical Engineering.

[20]  W. Chew,et al.  Reconstruction of two-dimensional permittivity distribution using the distorted Born iterative method. , 1990, IEEE transactions on medical imaging.

[21]  E. C. Burdette,et al.  In Vivo Probe Measurement Technique for Determining Dielectric Properties at VHF through Microwave Frequencies , 1980 .

[22]  A. Devaney,et al.  Super-resolution in diffraction tomography , 1992 .

[23]  J. Richmond Scattering by a dielectric cylinder of arbitrary cross section shape , 1965 .

[24]  A. Hippel,et al.  Dielectric Materials and Applications , 1995 .

[25]  L. E. Larsen,et al.  Microwave scattering parameter imagery of an isolated canine kidney. , 1979, Medical physics.

[26]  Jean-Paul Hugonin,et al.  Microwave imaging-complex permittivity reconstruction-by simulated annealing , 1991 .

[27]  M. Hawley,et al.  Noninvasive Control of Hyperthermia , 1990 .

[28]  L. E. Larsen,et al.  Medical Applications of Microwave Imaging , 1986 .

[29]  J. H. Richmond,et al.  A Modulated Scattering Technique for Measurement of Field Distributions , 1955 .

[30]  S.Y. Semenov,et al.  Microwave tomography: two-dimensional system for biological imaging , 1996, IEEE Transactions on Biomedical Engineering.

[31]  P.M. Meaney,et al.  Microwave imaging for tissue assessment: initial evaluation in multitarget tissue-equivalent phantoms , 1996, IEEE Transactions on Biomedical Engineering.

[32]  Ying Wang,et al.  Nonlinear diffraction tomography: The use of inverse scattering for imaging , 1996 .

[33]  Peter Monk,et al.  The detection and monitoring of leukemia using electromagnetic waves: numerical analysis , 1995 .

[34]  John E. Dennis,et al.  Numerical methods for unconstrained optimization and nonlinear equations , 1983, Prentice Hall series in computational mathematics.

[35]  Mario Bertero,et al.  Resolution and super-resolution in inverse diffraction , 1997 .

[36]  Lluis Jofre,et al.  Planar and cylindrical active microwave temperature imaging: numerical simulations , 1992, IEEE Trans. Medical Imaging.