The progressive focusing correction technique for ultrasound beamforming

This work presents a novel method for digital ultrasound beamforming based on programmable table look-ups, in which vectors containing coded focusing information are efficiently stored, achieving an information density of a fraction of bit per acquired sample. Timing errors at the foci are within half the period of a master clock of arbitrarily high frequency to improve imaging quality with low resource requirements. The technique is applicable with conventional as well as with DeltaSigma converters. The bit-width of the focusing code and the number of samples per focus can be defined to improve both memory size and F# with controlled timing errors. In the static mode, the number of samples per focus is fixed, and in the dynamic approach that figure grows progressively, taking advantage of the increasing depth of focus. Furthermore, the latter has the lowest memory requirements. The technique is well suited for research purposes as well as for real-world applications, offering a degree of freedom not available with other approaches. It allows, for example, modifying the sampling instants to phase aberration correction, beamforming in layered structures, etc. The described modular and scalable prototype has been built using low-cost field programmable gate arrays (FPGAs). Experimental measurements are in good agreement with the theoretically expected errors

[1]  W. L. Beaver,et al.  Phase Error Effects in Phased Array Beam Steering , 1977 .

[2]  R. Pridham,et al.  Digital interpolation beamforming for low-pass and bandpass signals , 1979, Proceedings of the IEEE.

[3]  O. V. von Ramm,et al.  Delay Quantization Error in Phased Array Images , 1981, IEEE Transactions on Sonics and Ultrasonics.

[4]  G. Kino,et al.  Real-Time Digital Image Reconstruction: A Description of Imaging Hardware and an Analysis of Quantization Errors , 1984, IEEE Transactions on Sonics and Ultrasonics.

[5]  G. Kino Acoustic waves : devices, imaging, and analog signal processing , 1987 .

[6]  S. B. Park,et al.  A new digital phased array system for dynamic focusing and steering with reduced sampling rate. , 1990, Ultrasonic imaging.

[7]  W.E. Engeler,et al.  Real-time phased array imaging using digital beam forming and autonomous channel control , 1990, IEEE Symposium on Ultrasonics.

[8]  G. Trahey,et al.  Comparisons of image quality factors for phase aberration correction with diffuse and point targets: theory and experiments , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  B.D. Steinberg,et al.  Digital beamforming in ultrasound , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Abdullah Atalar,et al.  VLSI circuits for adaptive digital beamforming in ultrasound imaging , 1993, IEEE Trans. Medical Imaging.

[11]  J.F. Greenleaf,et al.  Ultrasonic dynamic focusing using an analog FIFO and asynchronous sampling , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  An efficient real time focusing delay calculation in ultrasonic imaging systems. , 1994, Ultrasonic imaging.

[13]  Edmonds Wa An Ultrasound Beamformer Using Oversampling , 1997 .

[14]  Martinez,et al.  A multirate scan conversion method , 2000, Ultrasonics.

[15]  Carlos Fritsch Yusta,et al.  AMPLIA: una arquitectura modular para el procesamiento y despliegue de imagen acústica , 2000 .

[16]  T. G. Noll,et al.  Low power delay calculation for digital beamforming in handheld ultrasound systems , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[17]  M. Karaman,et al.  Digital phased array beamforming using single-bit delta-sigma conversion with non-uniform oversampling , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  Jørgen Arendt Jensen,et al.  A new architecture for a single-chip multi-channel beamformer based on a standard FPGA , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[19]  K.F. Ustuner,et al.  Pulse-echo beamformer with high lateral and temporal resolution and depth-independent lateral response , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[20]  Pei-Jie Cao,et al.  Development of a real time digital high frequency annular array ultrasound imaging system , 2003, IEEE Symposium on Ultrasonics, 2003.

[21]  K. Ranganathan,et al.  Direct sampled I/Q beamforming for compact and very low-cost ultrasound imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.