Dynamic-MLC leaf control utilizing on-flight intensity calculations: a robust method for real-time IMRT delivery over moving rigid targets.

An algorithm is presented that allows for the control of multileaf collimation (MLC) leaves based entirely on real-time calculations of the intensity delivered over the target. The algorithm is capable of efficiently correcting generalized delivery errors without requiring the interruption of delivery (self-correcting trajectories), where a generalized delivery error represents anything that causes a discrepancy between the delivered and intended intensity profiles. The intensity actually delivered over the target is continually compared to its intended value. For each pair of leaves, these comparisons are used to guide the control of the following leaf and keep this discrepancy below a user-specified value. To demonstrate the basic principles of the algorithm, results of corrected delivery are shown for a leading leaf positional error during dynamic-MLC (DMLC) IMRT delivery over a rigid moving target. It is then shown that, with slight modifications, the algorithm can be used to track moving targets in real time. The primary results of this article indicate that the algorithm is capable of accurately delivering DMLC IMRT over a rigid moving target whose motion is (1) completely unknown prior to delivery and (2) not faster than the maximum MLC leaf velocity over extended periods of time. These capabilities are demonstrated for clinically derived intensity profiles and actual tumor motion data, including situations when the target moves in some instances faster than the maximum admissible MLC leaf velocity. The results show that using the algorithm while calculating the delivered intensity every 50 ms will provide a good level of accuracy when delivering IMRT over a rigid moving target translating along the direction of MLC leaf travel. When the maximum velocities of the MLC leaves and target were 4 and 4.2 cm/s, respectively, the resulting error in the two intensity profiles used was 0.1 +/- 3.1% and -0.5 +/- 2.8% relative to the maximum of the intensity profiles. For the same target motion, the error was shown to increase rapidly as (1) the maximum MLC leaf velocity was reduced below 75% of the maximum target velocity and (2) the system response time was increased.

[1]  J Yang,et al.  Smoothing intensity-modulated beam profiles to improve the efficiency of delivery. , 2001, Medical physics.

[2]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[3]  Paul Keall,et al.  Real-time DMLC IMRT delivery for mobile and deforming targets. , 2005, Medical physics.

[4]  Steve B Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. , 2003, Physics in medicine and biology.

[5]  Steve B. Jiang,et al.  A finite state model for respiratory motion analysis in image guided radiation therapy. , 2004, Physics in medicine and biology.

[6]  S Webb,et al.  A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a ‘breathing’ multileaf collimator , 2006, Physics in medicine and biology.

[7]  S Webb,et al.  IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view , 2006, Physics in medicine and biology.

[8]  L. Papie,et al.  The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery , 2003 .

[9]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[10]  P. Keall,et al.  Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: implications for 4D radiotherapy. , 2005, Medical physics.

[11]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[12]  Lech Papiez,et al.  DMLC leaf‐pair optimal control of IMRT delivery for a moving rigid target , 2004 .

[13]  Gregory C Sharp,et al.  Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[14]  Steve B. Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching , 2006, Physics in medicine and biology.

[15]  Radhe Mohan,et al.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[16]  S Webb,et al.  The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique , 2005, Physics in medicine and biology.

[17]  R Mohan,et al.  Predicting respiratory motion for four-dimensional radiotherapy. , 2004, Medical physics.

[18]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[19]  C. Ramsey,et al.  Leaf position error during conformal dynamic arc and intensity modulated arc treatments. , 2001, Medical physics.

[20]  S Webb,et al.  Does elastic tissue intrafraction motion with density changes forbid motion-compensated radiotherapy? , 2006, Physics in medicine and biology.

[21]  Alexei V Chvetsov L-curve analysis of radiotherapy optimization problems. , 2005, Medical physics.

[22]  Manish Kakar,et al.  Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS). , 2005, Physics in medicine and biology.

[23]  Lech Papiez,et al.  DMLC leaf-pair optimal control for mobile, deforming target. , 2005, Medical physics.

[24]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[25]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[26]  P Keall,et al.  Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery. , 2005, Medical physics.