Localization of source with unknown amplitude using IPMC sensor arrays

The lateral line system, consisting of arrays of neuromasts functioning as flow sensors, is an important sensory organ for fish that enables them to detect predators, locate preys, perform rheotaxis, and coordinate schooling. Creating artificial lateral line systems is of significant interest since it will provide a new sensing mechanism for control and coordination of underwater robots and vehicles. In this paper we propose recursive algorithms for localizing a vibrating sphere, also known as a dipole source, based on measurements from an array of flow sensors. A dipole source is frequently used in the study of biological lateral lines, as a surrogate for underwater motion sources such as a flapping fish fin. We first formulate a nonlinear estimation problem based on an analytical model for the dipole-generated flow field. Two algorithms are presented to estimate both the source location and the vibration amplitude, one based on the least squares method and the other based on the Newton-Raphson method. Simulation results show that both methods deliver comparable performance in source localization. A prototype of artificial lateral line system comprising four ionic polymer-metal composite (IPMC) sensors is built, and experimental results are further presented to demonstrate the effectiveness of IPMC lateral line systems and the proposed estimation algorithms.

[1]  S. Graziani,et al.  A Tactile Sensor for Biomedical Applications Based on IPMCs , 2008, IEEE Sensors Journal.

[2]  G. Krijnen,et al.  Dipole-source localization using biomimetic flow-sensor arrays positioned as lateral-line system , 2010 .

[3]  Douglas L. Jones,et al.  Artificial lateral line with biomimetic neuromasts to emulate fish sensing , 2010, Bioinspiration & biomimetics.

[4]  Douglas L. Jones,et al.  Multisensor Processing Algorithms for Underwater Dipole Localization and Tracking Using MEMS Artificial Lateral-Line Sensors , 2006, EURASIP J. Adv. Signal Process..

[5]  Xiaobo Tan,et al.  A dynamic model for ionic polymer–metal composite sensors , 2007 .

[6]  Kevin M. Farinholt,et al.  Modeling of electromechanical charge sensing in ionic polymer transducers , 2004 .

[7]  E. Biddiss,et al.  Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite. , 2006, Medical engineering & physics.

[8]  Mohsen Shahinpoor,et al.  Blood pressure, pulse rate, and rhythm measurement using ionic polymer-metal composite sensors , 1999, Smart Structures.

[9]  Maurizio Porfiri,et al.  Free-Locomotion of Underwater Vehicles Actuated by Ionic Polymer Metal Composites , 2010, IEEE/ASME Transactions on Mechatronics.

[10]  K. Kim,et al.  Ionic polymer-metal composites: I. Fundamentals , 2001 .

[11]  Sheryl Coombs,et al.  Smart Skins: Information Processing by Lateral Line Flow Sensors , 2001, Auton. Robots.

[12]  K. Kim,et al.  Ionic polymer–metal composites: II. Manufacturing techniques , 2003 .

[13]  Jelle Atema,et al.  The importance of the lateral line in nocturnal predation of piscivorous catfish , 2004, Journal of Experimental Biology.

[14]  Xiaobo Tan,et al.  Underwater source localization using an IPMC-based artificial lateral line , 2011, 2011 IEEE International Conference on Robotics and Automation.

[15]  S. Graziani,et al.  A sensor-actuator integrated system based on IPMCs [ionic polymer metal composites] , 2004, Proceedings of IEEE Sensors, 2004..

[16]  Jelle Atema,et al.  Sharks need the lateral line to locate odor sources: rheotaxis and eddy chemotaxis , 2007, Journal of Experimental Biology.

[17]  K. Kim,et al.  Ionic polymer–metal composites: IV. Industrial and medical applications , 2005 .

[18]  Xiaobo Tan,et al.  Modeling and Inverse Compensation of Temperature-Dependent Ionic Polymer–Metal Composite Sensor Dynamics , 2011, IEEE/ASME Transactions on Mechatronics.

[19]  Sia Nemat-Nasser,et al.  Electromechanical response of ionic polymer-metal composites , 2000 .

[20]  Mohsen Shahinpoor,et al.  Ion-exchange-metal composite sensor films , 1997, Smart Structures.

[21]  M. Porfiri,et al.  A Particle Image Velocimetry Study of Vibrating Ionic Polymer Metal Composites in Aqueous Environments , 2009, IEEE/ASME Transactions on Mechatronics.

[22]  Xiaobo Tan,et al.  Monolithic fabrication of ionic polymer–metal composite actuators capable of complex deformation , 2010 .

[23]  Sheryl Coombs,et al.  Information Processing by the Lateral Line System , 2003 .

[24]  T. Pitcher,et al.  A blind fish can school. , 1976, Science.

[25]  Xiaobo Tan,et al.  A Control-Oriented and Physics-Based Model for Ionic Polymer--Metal Composite Actuators , 2008, IEEE/ASME Transactions on Mechatronics.

[26]  Douglas L. Jones,et al.  Distant touch hydrodynamic imaging with an artificial lateral line , 2006, Proceedings of the National Academy of Sciences.

[27]  Xiaobo Tan,et al.  Modeling of Biomimetic Robotic Fish Propelled by An Ionic Polymer–Metal Composite Caudal Fin , 2010, IEEE/ASME Transactions on Mechatronics.

[28]  Mohsen Shahinpoor,et al.  Use of ionic polymer-metal composites (IPMCs) as a pressure transducer in the human spine , 1999, Smart Structures.