Method for continuous nondisturbing monitoring of blood pressure by magnetoelastic skin curvature sensor and ECG

This paper concerns continuous nondisturbing estimation of blood pressure using mechanical plethysmography in connection with standard electrocardiography (ECG). The plethysmography is given by a novel magnetoelastic skin curvature sensor (SC-sensor) applied on the neck over the carotid artery. The sensor consists of a magnetoelastic bilayer partly enclosed by a coil. Bending the bilayer causes large changes of magnetic permeability which can be measured by the coil. The SC-sensor signal and the ECG signal are adaptively processed in order to estimate blood pressure according to a specifically established theoretical model. The model uses estimated vessel radius changes and pulse transit time as parameters. The results show cross correlation coefficients in the range 0.8 up to 0.9 between reference and estimated values of systolic blood pressure, diastolic blood pressure, and systolic/diastolic blood pressure change, whereas the estimation error was below 4 +/- 7 mmHg at rest and increased with the stress level. Limitations of the model applicability are given by a hysteretic behavior of both model parameters due to inert changes in artery stiffness. The SC-sensor and the ECG electrodes cause minimal inconvenience to the patient and offer an approach for a continuous nondisturbing monitoring of blood pressure changes, as being relevant for sleep monitoring or biomechanic feedback

[1]  Y. Shau,et al.  Noninvasive assessment of the viscoelasticity of peripheral arteries. , 1999, Ultrasound in medicine & biology.

[2]  M. Rohn,et al.  Magnetoelastic skin curvature sensor for biomedical applications , 2004, Proceedings of IEEE Sensors, 2004..

[3]  C. H. Chen,et al.  Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. , 1997, Circulation.

[4]  N. Bachl,et al.  Magnetorestictive amorphous sensor for biomedical monitoring , 1992, 1992. Digests of Intermag. International Magnetics Conference.

[5]  L. A. Geddes,et al.  Pulse arrival time as a method of obtaining systolic and diastolic blood pressure indirectly , 1981, Medical and Biological Engineering and Computing.

[6]  M Poliac,et al.  A new noninvasive method to measure blood pressure: results of a multicenter trial. , 1999, Anesthesiology.

[7]  S. Eckert,et al.  Comparison of Portapres non-invasive blood pressure measurement in the finger with intra-aortic pressure measurement during incremental bicycle exercise , 2002, Blood pressure monitoring.

[8]  D. Franchi,et al.  Blood pressure evaluation based on arterial pulse wave velocity , 1996, Computers in Cardiology 1996.

[9]  A. Steptoe,et al.  Pulse wave velocity as a measure of blood pressure change. , 1976, Psychophysiology.

[10]  L. Mehnen,et al.  A magnetostrictive acceleration sensor for registration of chest wall displacements , 2000 .

[11]  T. Kurki,et al.  Noninvasive continuous blood pressure measurement from the finger: Optimal measurement conditions and factors affecting reliability , 2004, Journal of Clinical Monitoring.

[12]  Timothy J. Pedley,et al.  The fluid mechanics of large blood vessels , 1980 .

[13]  D Barschdorff,et al.  [Continuous blood pressure monitoring during stress ECG]. , 1998, Biomedizinische Technik. Biomedical engineering.

[14]  Kiyomi Niki,et al.  Relationship between the pressure and diameter of the carotid artery in humans , 2000, Heart and Vessels.

[15]  T. Pedley The Fluid Mechanics of Large Blood Vessels: Contents , 1980 .

[16]  D. Barschdorff,et al.  Kontinuierliche Blutdruckbestimmung während des Belastungs-EKG - Continuous Blood Pressure Determination during Exercise ECG Recording , 1998 .