Identification of synchronous machine linear parameters from standstill step voltage input data

This paper presents the results of a time-domain identification procedure to estimate the linear parameters of a 15 kVA salient-pole synchronous machine at standstill. A step voltage input test is performed, and the parameters of the time constant models and equivalent circuit models are estimated. The maximum likelihood algorithm is used for the estimation, and the best-fit model is selected from a set of increasing order models. The initialization values for the parameters to be estimated are determined from the operational inductances derived directly from the measured time domain data. The simulated equivalent circuit model response is validated against the measured standstill time domain and frequency domain data. In addition, simulation of the model response to an on-line small disturbance test is compared to the measured dynamic response. >

[1]  Philippe Viarouge,et al.  Identification of generalised models of synchronous machines from time-domain tests , 1991 .

[2]  Ali Keyhani,et al.  Maximum likelihood estimation of synchronous machine parameters from standstill time response data , 1994 .

[3]  F.P. de Mello,et al.  Derivation of synchronous machine parameters from tests , 1977, IEEE Transactions on Power Apparatus and Systems.

[4]  P. L. Dandeno,et al.  Development of Detailed Turbogenerator Equivalent Circuits from Standstill Frequency Response Measurements , 1981 .

[5]  Karl Johan Åström Maximum likelihood and prediction error methods , 1980, Autom..

[6]  M. J. Gibbard,et al.  Identification of synchronous machine parameters from standstill tests using recursive estimation with the bilinear operator , 1992 .

[7]  A. M. El-Serafi,et al.  Determination of the parameters representing the cross-magnetizing effect in saturated synchronous machines , 1993 .

[8]  A.B.J. Reece,et al.  The D.c. Decay Test for Determining Synchronous Machine Parameters: Measurement and Simulation , 1989, IEEE Power Engineering Review.

[9]  K. Åström,et al.  Uniqueness of the maximum likelihood estimates of the parameters of an ARMA model , 1974 .

[10]  Ali Keyhani,et al.  Maximum likelihood estimation of generator stability constants using SSER test data , 1991 .

[11]  R. C. Beck,et al.  Time-domain identification of synchronous machine parameters from simple standstill tests , 1990 .

[12]  I. M. Canay,et al.  Causes of Discrepancies on Calculation of Rotor Quantities and Exact Equivalent Diagrams of the Synchronous Machine , 1969 .

[13]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..