Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs.

PURPOSE Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. METHODS The proposed method consists of two steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as "iFBP-TV" and "TV-FADM," respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. RESULTS The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. CONCLUSIONS Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.

[1]  Marc Kachelrieß,et al.  Empirical beam hardening correction (EBHC) for CT. , 2010, Medical physics.

[2]  Maik Stille,et al.  Augmented Likelihood Image Reconstruction , 2016, IEEE Transactions on Medical Imaging.

[3]  Habib Zaidi,et al.  3D Prior Image Constrained Projection Completion for X-ray CT Metal Artifact Reduction , 2013, IEEE Transactions on Nuclear Science.

[4]  Pei-Jan Paul Lin,et al.  A review of factors that affect artifact from metallic hardware on multi-row detector computed tomography. , 2010, Current problems in diagnostic radiology.

[5]  F Verhaegen,et al.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes , 2009, Physics in medicine and biology.

[6]  M. Jiang,et al.  High-order total variation minimization for interior tomography , 2010, Inverse problems.

[7]  Jeffrey A. Fessler,et al.  Fast X-Ray CT Image Reconstruction Using a Linearized Augmented Lagrangian Method With Ordered Subsets , 2014, IEEE Transactions on Medical Imaging.

[8]  Willi A Kalender,et al.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography , 2009, Physics in medicine and biology.

[9]  P. Suetens,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[10]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[11]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[12]  Xin Jin,et al.  A limited-angle CT reconstruction method based on anisotropic TV minimization , 2013, Physics in medicine and biology.

[13]  S. Strother,et al.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography. , 1993, Medical physics.

[14]  C T Chen,et al.  Correction for photon attenuation in SPECT: analytical framework, average attenuation factors, and a new hybrid approach. , 1993, Physics in medicine and biology.

[15]  Bin Yan,et al.  Efficient TpV minimization for circular, cone-beam computed tomography reconstruction via non-convex optimization , 2015, Comput. Medical Imaging Graph..

[16]  D. Fleischmann,et al.  Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. , 2011, Radiology.

[17]  Mehran Yazdi,et al.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. , 2005, International journal of radiation oncology, biology, physics.

[18]  Bin Yan,et al.  Efficient and robust 3D CT image reconstruction based on total generalized variation regularization using the alternating direction method. , 2015, Journal of X-ray science and technology.

[19]  Rainer Raupach,et al.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. , 2003, Investigative radiology.

[20]  Cyrill Burger,et al.  Artifacts at PET and PET/CT caused by metallic hip prosthetic material. , 2003, Radiology.

[21]  Z. Liang,et al.  Compensation for attenuation, scatter, and detector response in SPECT reconstruction via iterative FBP methods. , 1993, Medical physics.

[22]  Gengsheng Lawrence Zeng,et al.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm , 2000, IEEE Transactions on Medical Imaging.

[23]  Patrick Dupont,et al.  Reduction of metal streak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm , 1999 .

[24]  M. Kachelriess,et al.  Improved total variation-based CT image reconstruction applied to clinical data , 2011, Physics in medicine and biology.

[25]  Bin Yan,et al.  Image reconstruction based on total-variation minimization and alternating direction method in linear scan computed tomography , 2013 .

[26]  Jikun Wei,et al.  X-ray CT high-density artefact suppression in the presence of bones , 2004, Physics in medicine and biology.

[27]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[28]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[29]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[30]  Bin Yan,et al.  Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization. , 2014, Journal of X-ray science and technology.

[31]  Marc Kachelrieß,et al.  Segmentation-free empirical beam hardening correction for CT. , 2015, Medical physics.

[32]  Yin Zhang,et al.  An efficient augmented Lagrangian method with applications to total variation minimization , 2013, Computational Optimization and Applications.

[33]  David Faul,et al.  Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion , 2009, IEEE Transactions on Medical Imaging.

[34]  Chye Hwang Yan,et al.  Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction , 2000, IEEE Transactions on Medical Imaging.

[35]  A. Bovik,et al.  A universal image quality index , 2002, IEEE Signal Processing Letters.

[36]  Joseph A O'Sullivan,et al.  Image reconstruction for transmission tomography when projection data are incomplete , 2006, Physics in medicine and biology.

[37]  Lothar Spies,et al.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. , 2006, Medical physics.

[38]  Xuanqin Mou,et al.  Weighted Total Variation constrained reconstruction for reduction of metal artifact in CT , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[39]  Jeffrey A. Fessler,et al.  Alternating Direction Method of Multiplier for Tomography With Nonlocal Regularizers , 2014, IEEE Transactions on Medical Imaging.

[40]  Jianhua Ma,et al.  Total Variation-Stokes Strategy for Sparse-View X-ray CT Image Reconstruction , 2014, IEEE Transactions on Medical Imaging.

[41]  Johan Nuyts,et al.  Metal artifact reduction in computed tomography using local models in an image block-iterative scheme. , 2012, Medical physics.

[42]  Bin Yan,et al.  Constrained Total Generalized p-Variation Minimization for Few-View X-Ray Computed Tomography Image Reconstruction , 2016, PloS one.

[43]  Rainer Raupach,et al.  Frequency split metal artifact reduction (FSMAR) in computed tomography. , 2012, Medical physics.

[44]  Xiaoming Yuan,et al.  Alternating algorithms for total variation image reconstruction from random projections , 2012 .

[45]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[46]  Jeffrey A. Fessler,et al.  Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.

[47]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[48]  Junfeng Yang,et al.  A New Alternating Minimization Algorithm for Total Variation Image Reconstruction , 2008, SIAM J. Imaging Sci..

[49]  Steve B. Jiang,et al.  A hybrid metal artifact reduction algorithm for x-ray CT. , 2013, Medical physics.