Recent problems experienced with motor and generator windings

In many respects, large motors and generators in petrochemical plants have become a commodity product with intense competition amongst manufacturers from around the world to secure orders. This has resulted in pressure on machine designers to reduce manufacturing costs. Some of the methods employed to accomplish this include: • Reducing the conductor cross section • Reducing the insulation thickness • Reducing the amount of steel core material • Developing manufacturing methods that result in less time to manufacture. Each of these methods tends to increase the operating temperature of the windings or put additional voltage stress on the electrical insulation. Many design and processing innovations have been successfully implemented. However, there are both anecdotal and statistical data that indicates that there are more problems with machines made in the past 10 years, as compared to machines made previously. Engineering firms and end-users perhaps need to provide comprehensive, yet reasonable, purchase specifications that allow all manufacturers to compete on a level playing field. This paper is mainly concerned with stator windings rated greater than 6 kV, and rotors of various sized machines.

[1]  R. E. Draper,et al.  Utilizing reduced build concepts in the development of insulation systems for large motors , 1999, Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035).

[2]  G.C. Soukup,et al.  Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors , 1991, Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference.

[3]  G.C. Stone,et al.  Effect of manufacturer, winding age and insulation type on stator winding partial discharge levels , 2004, IEEE Electrical Insulation Magazine.

[4]  P.E.C.V. Maughan Root-cause diagnostics of generator service failures , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[5]  M. Liese,et al.  Design-dependent slot discharge and vibration sparking on high voltage windings , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  G. Stone,et al.  Electrical Insulation for Rotating Machines , 2003 .

[7]  J.C.G. Wheeler,et al.  Effects of converter pulses on the electrical insulation in low and medium voltage motors , 2005, IEEE Electrical Insulation Magazine.

[8]  E. I. Neville Glew Design and manufacture of energy efficient and environmentally friendly large machines , 1998 .

[9]  W. Chen,et al.  Stator insulation system evaluation and improvement for medium voltage adjustable speed drive applications , 2008, 2008 55th IEEE Petroleum and Chemical Industry Technical Conference.

[10]  G. Stone A suggested approach for specifying partial discharge testing as a new winding acceptance test , 2005, Proceedings Electrical Insulation Conference and Electrical Manufacturing Expo, 2005..