A dosimetric evaluation of VMAT for the treatment of non‐small cell lung cancer

The purpose of this study was to demonstrate the dosimetric potential of volumetric‐modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non‐small cell lung cancer (NSCLC) with stereotactic body radiation therapy (SBRT). Fourteen patients treated with 3D CRT with varying tumor locations, tumor sizes, and dose fractionation schemes were chosen for study. The prescription doses were 48 Gy in 4 fractions, 52.5 Gy in 5 fractions, 57.5 Gy in 5 fractions, and 60 Gy in 3 fractions for 2, 5, 1, and 6 patients, respectively. VMAT treatment plans with a mix of two to three full and partial noncoplanar arcs with 5°–25° separations were retrospectively generated using Eclipse version 10.0. The 3D CRT and VMAT plans were then evaluated by comparing their target dose, critical structure dose, high dose spillage, and low dose spillage as defined according to RTOG 0813 and RTOG 0236 protocols. In the most dosimetrically improved case, VMAT was able to decrease the dose from 17.35 Gy to 1.54 Gy to the heart. The D2cm decreased in 11 of 14 cases when using VMAT. The three that worsened were still within the acceptance criteria. Of the 14 3D CRT plans, seven had a D2cm minor deviation, while only one of the 14 VMAT plans had a D2cm minor deviation. The R50% improved in 13 of the 14 VMAT cases. The one case that worsened was still within the acceptance criteria of the RTOG protocol. Of the 14 3D CRT plans, seven had an R50% deviation. Only one of the 14 VMAT plans had an R50% deviation, but it was still improved compared to the 3D CRT plan. In this cohort of patients, no evident dosimetric compromises resulted from planning SBRT treatments with VMAT relative to the 3D CRT treatment plans actually used in their treatment. PACS numbers: 87.50.‐a, 87.53.‐j, 87.55.‐x, 87.55.D‐, 87.55.dk, 87.55.de

[1]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[2]  J. M. Michalski,et al.  Long-term Results of RTOG 0236: A Phase II Trial of Stereotactic Body Radiation Therapy (SBRT) in the Treatment of Patients with Medically Inoperable Stage I Non-Small Cell Lung Cancer , 2014 .

[3]  D. Yan,et al.  Clinical applications of volumetric modulated arc therapy. , 2010, International journal of radiation oncology, biology, physics.

[4]  J. Nickson,et al.  Carcinoma of the lung. , 1957, The American journal of roentgenology, radium therapy, and nuclear medicine.

[5]  Geoffrey G. Zhang,et al.  Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique , 2011, Radiation oncology.

[6]  S. Senan,et al.  Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  M. Schell,et al.  Stereotactic body radiation therapy: the report of AAPM Task Group 101. , 2010, Medical physics.

[8]  Xiaoqin Jiang,et al.  Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) , 2011, Radiation oncology.

[9]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[10]  M Partridge,et al.  Optimising stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy--a planning study. , 2012, Clinical oncology (Royal College of Radiologists (Great Britain)).

[11]  B. Shank Technological Basis of Radiation Therapy: Practical Clinical Applications , 1985 .

[12]  Martha M Matuszak,et al.  Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  Hong Ye,et al.  Outcomes after stereotactic lung radiotherapy or wedge resection for stage I non-small-cell lung cancer. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[14]  Andrea Bezjak,et al.  Stereotactic body radiation therapy for inoperable early stage lung cancer. , 2010, JAMA.

[15]  Suresh Senan,et al.  Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  F. Khan,et al.  Levitt and Tapley's technological basis of radiation therapy : practical clinical applications , 1984 .

[17]  M. Martel,et al.  Radiation dose-volume effects in the lung. , 2010, International journal of radiation oncology, biology, physics.

[18]  A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours , 2012, Radiation oncology.

[19]  P. Keall,et al.  Inverse planning for four-dimensional (4D) volumetric modulated arc therapy. , 2010, Medical physics.