A technical solution to avoid partial scan artifacts in cardiac MDCT.

Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction images. The feasibility of a new approach to solve this problem is assessed. An anthropomorphic cardiac phantom and an anesthetized pig were scanned on a dual-source CT scanner using both full and partial scan acquisition modes under different conditions. Additional scans were conducted with the electrocardiogram (ECG) signal being in synchrony with the gantry rotation. In the animal study, a simple x-ray detector was used to generate a signal once per gantry rotation. This signal was then used to pace the pig's heart. Phantom studies demonstrated that partial scan artifacts are strongly dependent on the rotational symmetry of angular projections, which is determined by the object shape and composition and its position with respect to the isocenter. The degree of partial scan artifacts also depends on the location of the region of interest with respect to highly attenuating materials (bones, iodine, etc.) within the object. Single-source partial scan images (165 ms temporal resolution) were significantly less affected by partial scan artifacts compared to dual-source partial scan images (82 ms temporal resolution). When the ECG signal was in synchrony with the gantry rotation, the same cardiac phase always corresponded to the same positions of the x-ray tube(s) and, hence, the same scattering and beam hardening geometry. As a result, the range of image-to-image CT number variations for partial scan reconstruction images acquired in synchronized mode was decreased to that achieved using full reconstruction image data. The success of the new approach, which synchronizes the ECG signal with the position of the x-ray tube(s), was demonstrated both in the phantom and animal experiments.

[1]  E. Ritman,et al.  Impaired myocardial perfusion reserve in experimental hypercholesterolemia is independent of myocardial neovascularization. , 2007, American journal of physiology. Heart and circulatory physiology.

[2]  E. Ritman,et al.  Evaluation of Porcine Myocardial Microvascular Permeability and Fractional Vascular Volume Using 64-Slice Helical Computed Tomography (CT) , 2007, Investigative radiology.

[3]  Thomas J. Brady,et al.  Comprehensive cardiac CT study: Evaluation of coronary arteries, left ventricular function, and myocardial perfusion—Is it possible? , 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[4]  Georg Mühlenbruch,et al.  Cardiac CT: coronary arteries and beyond , 2007, European Radiology.

[5]  S. Achenbach,et al.  Current Role of Cardiac Computed Tomography , 2007, Herz Kardiovaskuläre Erkrankungen.

[6]  C. Herzog,et al.  CT of Cardiac Function , 2007, Journal of thoracic imaging.

[7]  T. Flohr,et al.  Chasing the heart: new developments for cardiac CT. , 2007, Journal of thoracic imaging.

[8]  Philip Costello,et al.  CT of coronary artery disease. , 2004, Radiology.

[9]  M. Oudkerk,et al.  Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature , 2006, Acta radiologica.

[10]  Jiang Hsieh,et al.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. , 2006, Medical physics.

[11]  Elliot K Fishman,et al.  Cardiac valve assessment with MR imaging and 64-section multi-detector row CT. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  Jonathan Lessick,et al.  Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. , 2006, JAMA.

[13]  Matthew J. Budoff,et al.  Assessment of Cardiac Function Using Multidetector Row Computed Tomography , 2006, Journal of computer assisted tomography.

[14]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[15]  Udo Hoffmann,et al.  Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions. , 2006, European journal of radiology.

[16]  Amir Lerman,et al.  Functional and structural remodeling of the myocardial microvasculature in early experimental hypertension. , 2006, American journal of physiology. Heart and circulatory physiology.

[17]  Konstantin Nikolaou,et al.  Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. , 2006, Journal of the American College of Cardiology.

[18]  G. Raff,et al.  Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. , 2005, Journal of the American College of Cardiology.

[19]  Heshui Shi,et al.  Noninvasive coronary angiography with multislice computed tomography. , 2005, JAMA.

[20]  Michael Grass,et al.  Artifact analysis and reconstruction improvement in helical cardiac cone beam CT , 2004, IEEE Transactions on Medical Imaging.

[21]  Richard D. White,et al.  Noninvasive imaging of coronary arteries: current and future role of multi-detector row CT. , 2004, Radiology.

[22]  Konstantin Nikolaou,et al.  Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. , 2004, Journal of the American College of Cardiology.

[23]  S. Achenbach,et al.  Detection of Calcified and Noncalcified Coronary Atherosclerotic Plaque by Contrast-Enhanced, Submillimeter Multidetector Spiral Computed Tomography: A Segment-Based Comparison With Intravascular Ultrasound , 2003, Circulation.

[24]  B. Ohnesorge,et al.  Heart Rate Adaptive Optimization of Spatial and Temporal Resolution for Electrocardiogram-Gated Multislice Spiral CT of the Heart , 2001, Journal of computer assisted tomography.

[25]  E. Ritman,et al.  Minimally Invasive Evaluation of Coronary Microvascular Function by Electron Beam Computed Tomography , 2000, Circulation.

[26]  M. Bell,et al.  Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers , 1999, Heart.

[27]  E L Ritman,et al.  Measurement of in vivo myocardial microcirculatory function with electron beam CT. , 1999, Journal of computer assisted tomography.

[28]  M. Budoff,et al.  Usefulness of electron beam computed tomography scanning for distinguishing ischemic from nonischemic cardiomyopathy. , 1998, Journal of the American College of Cardiology.

[29]  R. Morin,et al.  The technical design and performance of ultrafast computed tomography. , 1994, Radiologic clinics of North America.

[30]  E. Ritman,et al.  A fast computed tomographic imaging method for myocardial perfusion. , 1993, American journal of cardiac imaging.

[31]  C S Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data , 1983, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[32]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[33]  J. H. Stanley,et al.  A Proposed Dynamic Cardiac 3-D Densitometer for Early Detection and Evaluation of Heart Disease , 1979, IEEE Transactions on Nuclear Science.

[34]  Lilach O Lerman,et al.  Assessment of myocardial microvascular function: new opportunities in fast computed tomography. , 2007, Trends in cardiovascular medicine.

[35]  Michael Grass,et al.  Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. , 2005, Radiology.