Comparison of Anterior Segment Optical Coherence Tomography Bleb Grading, Moorfields Bleb Grading System, and Intraocular Pressure After Trabeculectomy

Purpose: To compare a novel anterior segment optical coherence tomography (AS-OCT) bleb grading system with a clinical bleb grading system and both with intraocular pressure (IOP) following trabeculectomy surgery. Materials and Methods: A novel AS-OCT grading system based on bleb size and internal reflectivity was developed. An imaging center was tasked with masked grading of AS-OCT images acquired by multiple surgical sites at postoperative week (POW) 2, postoperative month (POM) 4, 6, and 12, respectively. The Moorfields Bleb Grading System was used by another independent imaging center to grade clinical photos. The results of the 2 grading systems were compared and correlated with IOP. Results: Blebs of 124 eyes were assessed in this study. Higher (worse) AS-OCT bleb grades was significantly associated with: decreased bleb height at POM4, 6, and 12 (P<0.001, 0.001, and 0.0001), increased central bleb vascularity at POM4 and 12 (P=0.0026;0.036) and decreased maximal bleb area at POM6 and 12 (P=0.026; 0.01). A higher AS-OCT bleb grade correlated with a higher IOP at POM4 and 6 (P=0.004; 0.02), though no longer significant at POM12 (P=0.1). Increased maximum bleb vascularity was associated with increased IOP at POM4 (P=0.003) though none of the remaining MGBS parameters correlated significantly with IOP. Eyes with a final IOP of ⩽12 mm Hg had significantly lower AS-OCT bleb grades at POM6 (P=0.045). Conclusion: A novel AS-OCT bleb grading system correlated well with a number of Moorfields Bleb Grading System variables throughout the 1-year postoperative period. Although the AS-OCT grades also correlated well with IOP throughout most of the postoperative period, it was limited in their abilities to predict final IOP.

[1]  C Bunce,et al.  A Pilot Study of a System for Grading of Drainage Blebs after Glaucoma Surgery , 2004, Journal of glaucoma.

[2]  M. Araie,et al.  Clinical characteristics and leakage of functioning blebs after trabeculectomy with mitomycin-C in primary glaucoma patients. , 2003, Ophthalmology.

[3]  P. Chew,et al.  High‐definition imaging of trabeculectomy blebs using spectral domain optical coherence tomography adapted for the anterior segment , 2009, Clinical & experimental ophthalmology.

[4]  J. Funk,et al.  Internal reflectivity of filtering blebs versus intraocular pressure in patients with recent trabeculectomy. , 2011, Investigative ophthalmology & visual science.

[5]  Tin Aung,et al.  Anterior segment optical coherence tomography imaging of trabeculectomy blebs before and after laser suture lysis. , 2007, American journal of ophthalmology.

[6]  Pietro Emanuele Napoli,et al.  Qualitative and quantitative analysis of filtering blebs with optical coherence tomography. , 2014, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[7]  Masanori Hangai,et al.  Early trabeculectomy bleb walls on anterior-segment optical coherence tomography , 2010, Graefe's Archive for Clinical and Experimental Ophthalmology.

[8]  J. Funk,et al.  Evaluation of filtering blebs using the ‘Wuerzburg bleb classification score’ compared to clinical findings , 2012, BMC Ophthalmology.

[9]  Atsuya Miki,et al.  The Assessment of the Filtering Bleb Function With Anterior Segment Optical Coherence Tomography , 2010, Journal of glaucoma.

[10]  G. Schlunck,et al.  Interobserver Variability of the Würzburg Bleb Classification Score , 2005, Ophthalmologica.

[11]  Y. Kitazawa,et al.  An ultrasound biomicroscopic study of filtering blebs after mitomycin C trabeculectomy. , 1995, Ophthalmology.

[12]  Piero Barboni,et al.  Filtering blebs imaging by optical coherence tomography , 2005, Clinical & experimental ophthalmology.

[13]  A. Wells,et al.  Comparison of two clinical Bleb grading systems. , 2006, Ophthalmology.

[14]  H. Tanihara,et al.  Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography , 2014, Clinical ophthalmology.

[15]  R. Guthoff,et al.  The Prognostic Value of the Wuerzburg Bleb Classification Score for the Outcome of Trabeculectomy , 2010, Ophthalmologica.

[16]  Christopher Kai-shun Leung,et al.  Analysis of bleb morphology after trabeculectomy with Visante anterior segment optical coherence tomography , 2006, British Journal of Ophthalmology.

[17]  Yoshiaki Yasuno,et al.  Evaluation of trabeculectomy blebs using 3-dimensional cornea and anterior segment optical coherence tomography. , 2009, Ophthalmology.

[18]  Louis B. Cantor,et al.  Morphologic Classification of Filtering Blebs after Glaucoma Filtration Surgery: The Indiana Bleb Appearance Grading Scale , 2003, Journal of glaucoma.

[19]  H. Tanihara,et al.  Evaluation of filtering blebs exhibiting transconjunctival oozing using anterior segment optical coherence tomography , 2015, Graefe's Archive for Clinical and Experimental Ophthalmology.

[20]  Yoshiaki Yasuno,et al.  Noninvasive evaluation of phase retardation in blebs after glaucoma surgery using anterior segment polarization-sensitive optical coherence tomography. , 2014, Investigative ophthalmology & visual science.

[21]  M. Kurano,et al.  Increased aqueous autotaxin and lysophosphatidic acid levels are potential prognostic factors after trabeculectomy in different types of glaucoma , 2018, Scientific Reports.

[22]  J. E. Cairns Trabeculectomy. Preliminary report of a new method. , 1968, American journal of ophthalmology.

[23]  F. Grehn,et al.  Classification of filtering blebs in trabeculectomy: biomicroscopy and functionality , 1998, Current opinion in ophthalmology.

[24]  Y. Fujikoshi,et al.  Bleb analysis by using anterior segment optical coherence tomography in two different methods of trabeculectomy. , 2013, Investigative ophthalmology & visual science.

[25]  H. Tanihara,et al.  Filtering blebs using 3-dimensional anterior-segment optical coherence tomography: a prospective investigation. , 2015, JAMA ophthalmology.

[26]  V. Vasavada,et al.  Morphology of functioning trabeculectomy blebs using anterior segment optical coherence tomography , 2014, Indian journal of ophthalmology.

[27]  Y. Buys,et al.  Correlation Between the Indiana Bleb Appearance Grading Scale and Intraocular Pressure After Phacotrabeculectomy , 2009, Journal of glaucoma.

[28]  A. Wells,et al.  Information Loss in 2 Bleb Grading Systems , 2007, Journal of glaucoma.

[29]  Tin Aung,et al.  Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. , 2007, Ophthalmology.