Elevations of diffusion anisotropy are associated with hyper-acute stroke: a serial imaging study.

Diffusion tensor imaging (DTI) studies of human ischemic stroke within 24 h of symptom onset have reported variable findings of changes in diffusion anisotropy. Serial DTI within 24 h may clarify these heterogeneous results. We characterized longitudinal changes of diffusion anisotropy by analyzing discrete ischemic white matter (WM) and gray matter (GM) regions during the hyperacute (2.5-7 h) and acute (21.5-29 h) scanning phases of ischemic stroke onset in 13 patients. Mean diffusivity (MD), fractional anisotropy (FA) and T2-weighted signal intensity were measured for deep and subcortical WM and deep and cortical GM areas in lesions outlined by a > or =30% decrease in MD. Average reductions of approximately 40% in relative (r) MD were observed in all four brain regions during both the hyperacute and acute phases post stroke. Overall, 9 of 13 patients within 7 h post symptom onset showed elevated FA in at least one of the four tissues, and within the same cohort, 11 of 13 patients showed reduced FA in at least one of the ischemic WM and GM regions at 21.5-29 h after stroke. The fractional anisotropy in the lesion relative to the contralateral side (rFA, mean+/-S.D.) was significantly elevated in some patients in the deep WM (1.10+/-0.11, n=4), subcortical WM (1.13+/-0.14, n=4), deep GM (1.07+/-0.06, n=1) and cortical GM (1.22+/-0.13, n=5) hyperacutely (< or =7 h); however, reductions of rFA at approximately 24 h post stroke were more consistent (rFA= 0.85+/-0.12).

[1]  J. Gore,et al.  Compartmental study of diffusion and relaxation measured in vivo in normal and ischemic rat brain and trigeminal nerve , 2000, Magnetic resonance in medicine.

[2]  C. Sotak,et al.  Multispectral analysis of the temporal evolution of cerebral ischemia in the rat brain , 2000, Journal of magnetic resonance imaging : JMRI.

[3]  Shu-Wei Sun,et al.  Differential sensitivity of in vivo and ex vivo diffusion tensor imaging to evolving optic nerve injury in mice with retinal ischemia , 2006, NeuroImage.

[4]  T E Conturo,et al.  Differences between gray matter and white matter water diffusion in stroke: diffusion-tensor MR imaging in 12 patients. , 2000, Radiology.

[5]  A Gregory Sorensen,et al.  Assessing tissue viability with MR diffusion and perfusion imaging. , 2003, AJNR. American journal of neuroradiology.

[6]  Volkmar Glauche,et al.  Diffusion tensor imaging detects early Wallerian degeneration of the pyramidal tract after ischemic stroke , 2004, NeuroImage.

[7]  C. Beaulieu,et al.  Longitudinal magnetic resonance imaging study of perfusion and diffusion in stroke: Evolution of lesion volume and correlation with clinical outcome , 1999, Annals of neurology.

[8]  C. Sotak,et al.  The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review , 2002, NMR in biomedicine.

[9]  Shu-Wei Sun,et al.  Diffusion tensor imaging detects and differentiates axon and myelin degeneration in mouse optic nerve after retinal ischemia , 2003, NeuroImage.

[10]  R. Gonzalez,et al.  Serial Diffusion Tensor MRI After Transient and Permanent Cerebral Ischemia in Nonhuman Primates , 2007, Stroke.

[11]  T. L. Davis,et al.  Human acute cerebral ischemia: detection of changes in water diffusion anisotropy by using MR imaging. , 1999, Radiology.

[12]  D M Doddrell,et al.  An evaluation of the time dependence of the anisotropy of the water diffusion tensor in acute human ischemia. , 1999, Magnetic resonance imaging.

[13]  M. Moseley,et al.  Real‐time observation of transient focal ischemia and hyperemia in cat brain , 1992, Magnetic resonance in medicine.

[14]  Usha Sinha,et al.  Quantitative Metrics for Evaluating Parallel Acquisition Techniques in Diffusion Tensor Imaging at 3 Tesla , 2006, Investigative radiology.

[15]  Wei Li,et al.  Fast magnetic resonance diffusion‐weighted imaging of acute human stroke , 1992, Neurology.

[16]  C. Weiller,et al.  Checkerboard fields in multiple sclerosis , 2005, Journal of Neurology, Neurosurgery & Psychiatry.

[17]  R. Sevick,et al.  A comparison of images generated from diffusion‐weighted and diffusion‐tensor imaging data in hyper‐acute stroke , 2004, Journal of magnetic resonance imaging : JMRI.

[18]  A. Sorensen,et al.  MRI measurements of water diffusion: impact of region of interest selection on ischemic quantification. , 2004, European journal of radiology.

[19]  J. Kucharczyk,et al.  Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopy , 1990, Magnetic resonance in medicine.

[20]  C. Beaulieu,et al.  Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging. , 2007, AJNR. American journal of neuroradiology.

[21]  A Gregory Sorensen,et al.  Evolution of water diffusion and anisotropy in hyperacute stroke: significant correlation between fractional anisotropy and T2. , 2004, AJNR. American journal of neuroradiology.

[22]  S M Davis,et al.  Serial study of apparent diffusion coefficient and anisotropy in patients with acute stroke. , 1999, Stroke.

[23]  Luis Concha,et al.  Diffusion tensor imaging of time-dependent axonal and myelin degradation after corpus callosotomy in epilepsy patients , 2006, NeuroImage.

[24]  Timothy Q. Duong,et al.  Pixel-by-Pixel Spatiotemporal Progression of Focal Ischemia Derived Using Quantitative Perfusion and Diffusion Imaging , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[25]  S. Warach,et al.  Magnetic Resonance Imaging Criteria for Thrombolysis in Acute Cerebral Infarct , 2005, Stroke.

[26]  Eku Shimosegawa,et al.  Detection of Deoxygenation-Related Signal Change in Acute Ischemic Stroke Patients by T2*-Weighted Magnetic Resonance Imaging , 2002, Stroke.

[27]  Khader M Hasan,et al.  Focal Wallerian degeneration of the corpus callosum in large middle cerebral artery stroke: Serial diffusion tensor imaging , 2006, Journal of magnetic resonance imaging : JMRI.

[28]  John D Pickard,et al.  Increased Anisotropy in Acute Stroke: A Possible Explanation , 2002, Stroke.

[29]  Raphaël Porcher,et al.  Longitudinal Diffusion Changes in Cerebral Hemispheres after MCA Infarcts , 2005, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[30]  R R Edelman,et al.  Time course of the apparent diffusion coefficient (ADC) abnormality in human stroke , 1997, Neurology.

[31]  P. Basser,et al.  A model for diffusion in white matter in the brain. , 2005, Biophysical journal.

[32]  M. Harada,et al.  Change of diffusion anisotropy in patients with acute cerebral infarction using statistical parametric analysis , 2006, Radiation Medicine.

[33]  David H. Miller,et al.  Diffusion tensor imaging can detect and quantify corticospinal tract degeneration after stroke , 2000, Journal of neurology, neurosurgery, and psychiatry.

[34]  P. Basser,et al.  Water Diffusion Changes in Wallerian Degeneration and Their Dependence on White Matter Architecture , 2000 .

[35]  C. Beaulieu,et al.  The Relationship between Diffusion Anisotropy and Time of Onset after Stroke , 2006, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[36]  D. Parker,et al.  A geometric analysis of diffusion tensor measurements of the human brain , 2000, Magnetic resonance in medicine.

[37]  M E Bastin,et al.  Temporal evolution of water diffusion parameters is different in grey and white matter in human ischaemic stroke , 2004, Journal of Neurology, Neurosurgery & Psychiatry.