Low frequency noise in arrays of magnetic tunnel junctions connected in series and parallel

Low frequency noise and small output voltage are the strongest limitations to the use of magnetic tunnel junctions (MTJs) for magnetic sensor applications, replacing giant magnetoresistance (GMR) and anisotropic magnetoresistance sensors. In this paper, we explore the possibility of using arrays with a large number of MTJs connected in parallel/series to overcome these limitations. MTJ’s sensor arrays of more than 3×103 junction elements in different configurations have been fabricated. Low frequency noise and detectivity have been measured and compared to an analytical model, with detectivities of about 16 nT/Hz1/2 achieved in a series/parallel architecture. This detectivity levels are competitive with single devices based on GMR, with the advantage of not requiring additional flux concentrators.

[1]  L.K.J. Vandamme,et al.  Experimental studies on 1/f noise , 1981 .

[2]  Rogers,et al.  Nature of single-localized-electron states derived from tunneling measurements. , 1985, Physical review letters.

[3]  T. Miyazaki,et al.  Giant magnetic tunneling e ect in Fe/Al2O3/Fe junction , 1995 .

[4]  Kinder,et al.  Large magnetoresistance at room temperature in ferromagnetic thin film tunnel junctions. , 1995, Physical review letters.

[5]  Anita Fink,et al.  Picotesla field sensor design using spin-dependent tunneling devices , 1998 .

[6]  Cong Ren,et al.  Magnetic tunnel junction field sensors with hard-axis bias field , 2002 .

[7]  E. Tsymbal,et al.  Spin-dependent tunnelling in magnetic tunnel junctions , 2003 .

[8]  A. V. Pohm,et al.  Chopping techniques for low-frequency nanotesla spin-dependent tunneling field sensors , 2003 .

[9]  Renu W. Dave,et al.  Low-frequency magnetic and resistance noise in magnetic tunnel junctions , 2004 .

[10]  Stephen E. Russek,et al.  Low-frequency noise measurements on commercial magnetoresistive magnetic field sensors , 2005 .

[11]  Paulo P. Freitas,et al.  1/f noise in linearized low resistance MgO magnetic tunnel junctions , 2006 .

[12]  Michael Pedersen,et al.  Progress toward a thousandfold reduction in 1∕f noise in magnetic sensors using an ac microelectromechanical system flux concentrator (invited) , 2006 .

[13]  S. Ikeda,et al.  Effect of electrode composition on the tunnel magnetoresistance of pseudo-spin-valve magnetic tunnel junction with a MgO tunnel barrier , 2007 .

[14]  Gang Xiao,et al.  Thermal stability, sensitivity, and noise characteristics of MgO-based magnetic tunnel junctions (invited) , 2007 .

[15]  S. Cardoso,et al.  Improving Magnetic Field Detection Limits of Spin Valve Sensors Using Magnetic Flux Guide Concentrators , 2007, IEEE Transactions on Magnetics.

[16]  Claude Fermon,et al.  Noise in MgO barrier magnetic tunnel junctions with CoFeB electrodes: Influence of annealing temperature , 2007 .

[17]  M. Hehn,et al.  Very low 1/f noise at room temperature in fully epitaxial Fe/MgO/Fe magnetic tunnel junctions , 2007, 0803.3564.

[18]  Rui Zhang,et al.  Dependence of noise in magnetic tunnel junction sensors on annealing field and temperature , 2008 .

[19]  R. Macedo,et al.  Ion beam assisted deposition of MgO barriers for magnetic tunnel junctions , 2008 .

[20]  Paulo P. Freitas,et al.  MgO based picotesla field sensors , 2008 .

[21]  Philip W. T. Pong,et al.  Advances in magnetometry through miniaturization , 2008 .

[22]  João Pedro Conde,et al.  Hybrid magnetoresistive/microelectromechanical devices for static field modulation and sensor 1/f noise cancellation , 2008 .