Immediate restoration of nonsubmerged titanium implants with a sandblasted and acid-etched surface: five-year results of a prospective case series study using clinical and radiographic data.

The aim of this study was to evaluate the survival and success rates of immediately restored implants with sandblasted, large-grit, acid-etched (SLA) surfaces over a period of 5 years. Twenty patients (mean age, 47.3 years) received a total of 21 SLA wide-neck implants in healed mandibular first molar sites after initial periodontal treatment. To be included in the study, the implants had to demonstrate primary stability with an insertion torque value of 35 Ncm. A provisional restoration was fabricated chairside and placed on the day of surgery. Definitive cemented restorations were inserted 8 weeks after surgery. Community Periodontal Index of Treatment Needs (CPITN) indices and the radiographic distance between the implant shoulder and the first visible bone-implant contact (DIB) were measured and compared over the study period. The initial mean CPITN was 3.24, and decreased over the study period to 1.43. At the postoperative radiographic examination, the mean DIB was 1.41 mm for the 21 implants, indicating that part of the machined neck of the implants was placed slightly below the osseous crest. The mean DIB value increased to 1.99 mm at the 5-year examination. This increase proved to be statistically significant (P < .0001). Between the baseline and 5-year examinations, the mean bone crest level loss was 0.58 mm. Success and survival rates of the 21 implants after 5 years of function were 100%. This 5-year study confirms that immediate restoration of mandibular molar wide-neck implants with good primary stability, as noted by insertion torque values of at least 35 Ncm, is a safe and predictable procedure.

[1]  D. Buser,et al.  Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values. , 2009, Clinical implant dentistry and related research.

[2]  German O Gallucci,et al.  Consensus statements and recommended clinical procedures regarding loading protocols. , 2009, The International journal of oral & maxillofacial implants.

[3]  G. Huynh-Ba,et al.  History of treated periodontitis and smoking as risks for implant therapy. , 2009, The International journal of oral & maxillofacial implants.

[4]  J. Ganeles,et al.  Immediate and early loading of Straumann implants with a chemically modified surface (SLActive) in the posterior mandible and maxilla: 1-year results from a prospective multicenter study. , 2008, Clinical oral implants research.

[5]  Stephen T. Chen,et al.  Esthetic outcomes of immediate implant placements. , 2007, Clinical oral implants research.

[6]  J. Ganeles,et al.  Multicenter retrospective analysis of wide-neck dental implants for single molar replacement. , 2007, The International journal of oral & maxillofacial implants.

[7]  A. Lussi,et al.  Clinical performance of wide-body implants with a sandblasted and acid-etched (SLA) surface: results of a 3-year follow-up study in a referral clinic. , 2007, The International journal of oral & maxillofacial implants.

[8]  C. Scapoli,et al.  Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: a randomized controlled split-mouth study--machined versus titanium oxide implant surface. , 2007, The International journal of oral & maxillofacial implants.

[9]  H V Worthington,et al.  Interventions for replacing missing teeth: different times for loading dental implants. , 2013, The Cochrane database of systematic reviews.

[10]  D. Buser,et al.  Immediate loading of implants with 3-unit fixed partial dentures: a 12-month clinical study. , 2006, The International journal of oral & maxillofacial implants.

[11]  G. Romanos,et al.  Immediate versus delayed functional loading of implants in the posterior mandible: a 2-year prospective clinical study of 12 consecutive cases. , 2006, The International journal of periodontics & restorative dentistry.

[12]  R. Nedir,et al.  A five-year life-table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice. , 2006, Clinical oral implants research.

[13]  E. Nkenke,et al.  Indications for immediate loading of implants and implant success. , 2006, Clinical oral implants research.

[14]  S. Taschieri,et al.  Systematic review of survival rates for immediately loaded dental implants. , 2006, The International journal of periodontics & restorative dentistry.

[15]  Marcus Abboud,et al.  Immediate loading of single-tooth implants in the posterior region. , 2005, The International journal of oral & maxillofacial implants.

[16]  A. Lussi,et al.  Early loading of non-submerged titanium implants with a sandblasted and acid-etched surface. 5-year results of a prospective study in partially edentulous patients. , 2003, Clinical oral implants research.

[17]  Antonio Barone,et al.  Immediate restoration of single-tooth implants in mandibular molar sites: a 12-month preliminary report. , 2004, The International journal of oral & maxillofacial implants.

[18]  J. Ganeles,et al.  Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications. , 2004, The International journal of oral & maxillofacial implants.

[19]  M. Chiapasco Early and immediate restoration and loading of implants in completely edentulous patients. , 2004, The International journal of oral & maxillofacial implants.

[20]  H. Weber,et al.  Immediate restoration and loading of dental implants: clinical considerations and protocols. , 2004, The International journal of oral & maxillofacial implants.

[21]  B. Rangert,et al.  Immediate/early loading of dental implants: a report from the Sociedad Española de Implantes World Congress consensus meeting in Barcelona, Spain, 2002. , 2003, Clinical implant dentistry and related research.

[22]  B. Rangert,et al.  Immediate functional loading of Brånemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study. , 2003, Clinical implant dentistry and related research.

[23]  M. Martignoni,et al.  Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial. , 2003, Clinical implant dentistry and related research.

[24]  B. Rangert,et al.  Immediate occlusal loading of single lower molars using Brånemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study. , 2003, Clinical implant dentistry and related research.

[25]  R. Mericske-Stern,et al.  A follow-up study of maxillary implants supporting an overdenture: clinical and radiographic results. , 2002, The International journal of oral & maxillofacial implants.

[26]  H. Haanaes,et al.  Immediate loading of single-tooth ITI implants in the anterior maxilla: a prospective 5-year pilot study. , 2002, Clinical oral implants research.

[27]  B. d'Hoedt,et al.  The longitudinal clinical effectiveness of ITI solid-screw implants in partially edentulous patients: a 5-year follow-up report. , 2000, The International journal of oral & maxillofacial implants.

[28]  C. T. ten Bruggenkate,et al.  Treatment of fully edentulous patients with ITI implants. , 2000, Clinical Oral Implants Research.

[29]  D. Buser,et al.  Basic surgical principles with ITI implants. , 2000, Clinical oral implants research.

[30]  J. Fiorellini,et al.  A 5-year prospective clinical and radiographic study of non-submerged dental implants. , 2000, Clinical oral implants research.

[31]  K. Arvidson,et al.  Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles. , 1998, Clinical oral implants research.

[32]  D Buser,et al.  Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. , 1997, Clinical oral implants research.

[33]  A. Ainamo,et al.  Validity and relevance of the criteria of the CPITN. , 1994, International Dental Journal.

[34]  I Herrmann,et al.  Osseointegrated implants for treatment of partially edentulous jaws: A 5 year prospective multicentre study , 1994 .

[35]  J. Fiorellini,et al.  Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants. , 1992, Clinical oral implants research.

[36]  D Buser,et al.  Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. , 1990, Clinical oral implants research.

[37]  A Schmitt,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part II: The prosthetic results. , 1990, The Journal of prosthetic dentistry.

[38]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[39]  G Zarb,et al.  The long-term efficacy of currently used dental implants: a review and proposed criteria of success. , 1986, The International journal of oral & maxillofacial implants.

[40]  F Sutter,et al.  The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. , 1981, Journal of maxillofacial surgery.

[41]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.