Hybrid modelling of inhomogeneous transformer winding for very fast transient overvoltage studies

This paper presents a novel approach for the modelling of transformer windings, which is valid in the frequency range of 10 kHz to a few MHz. It is a hybrid model; coil-by-coil detailed plus inter-coil black box model. The parameter estimation of the detailed model and the synthesis of the black box model is based on frequency domain measurements. The technique is applied to a high-voltage transformer winding. The comparison of the measurements and the frequency domain simulation of the model with EMTP confirms the validity and accuracy of the model for the intended frequency range. Experiments in the frequency range of several MHz reveal that remarkable overvoltages appear at the connecting point of the inverted and interleaved part of this winding. It is shown that the reason of the VFTO (very fast transient overvoltage) in the MHz range is the inhomogeneity of the winding parts.

[1]  A. S. Morched,et al.  A high frequency transformer model for the EMTP , 1993 .

[2]  F. de Leon,et al.  Reduced order model for transformer transients , 1992 .

[3]  R.J. Musil,et al.  Voltage Stresses Produced by Aperiodic and Oscillating System Overvoltages in Transformer Windings , 1981, IEEE Transactions on Power Apparatus and Systems.

[4]  Y. Liu,et al.  Modeling of converter transformers using frequency domain terminal impedance measurements , 1993 .

[5]  H. Mohseni Multi-Winding Milti-Phase Transformer Model with Saturable Core , 1991, IEEE Power Engineering Review.

[6]  Y. Liu,et al.  Power transformer resonance-measurements and prediction , 1992 .

[7]  R. C. Degeneff,et al.  Transformer model reduction using time and frequency domain sensitivity techniques , 1995 .

[8]  V. Brandwajn,et al.  Matrix Representation of Three-Phase N-Winding Transformers for Steady-State and Transient Studies , 1982, IEEE Power Engineering Review.

[9]  T. J. Blalock,et al.  Response of Transformer Windings to System Transient Voltages , 1974 .

[10]  R.C. Degeneff,et al.  A general method for determining resonances in transformer windings , 1977, IEEE Transactions on Power Apparatus and Systems.

[11]  Hermann A. Haus,et al.  Electromagnetic Fields And Energy , 1989 .

[12]  R. C. Degeneff,et al.  Nonlinear, lumped parameter transformer model reduction technique , 1995 .

[13]  László Kiss,et al.  Large Power Transformers , 1987 .

[14]  Adam Semlyen,et al.  Practical transfer function estimation and its application to wide frequency range representation of transformers , 1993 .

[15]  D. Konig,et al.  Study of power coil resonance phenomena based on traveling wave theory , 1991 .

[16]  Jose R. Marti,et al.  Simplified three-phase transformer model for electromagnetic transient studies , 1995 .

[17]  A. Keyhani,et al.  Parameter Estimation for Power Transformer Models from Time-Domain Data , 1986, IEEE Transactions on Power Delivery.

[18]  F. de Leon,et al.  Efficient calculation of elementary parameters of transformers , 1992 .

[19]  R. C. Degeneff,et al.  A method for constructing a reduced order transformer model for system studies from detailed lumped parameter models , 1991 .

[20]  V. Woivre,et al.  Transient overvoltage study and model for shell-type power transformers , 1993 .

[21]  F. de Leon,et al.  Complete transformer model for electromagnetic transients , 1994 .