Comparison of Electrical Impedance and 133Xenon Clearance for the Assessment of Cerebral Blood Flow in the Newborn Infant

ABSTRACT: The peak amplitude of pulsatile cerebral electrical impedance (ΔZp) was compared with simultaneous 133xenon clearance estimations of cerebral blood flow (CBF∞) on 28 occasions in nine infants receiving assisted ventilation who had changes in PaCO2 and thereby presumably in cerebral blood flow. Percentage changes from one measurement to the next in each infant were compared. Using linear regression the relationship was ΔZp = 0.5 CBF∞ – 1.5 with r = 0.67. The 95% confidence interval for the regression coefficient was 0.2–0.8 and the mean residual was 28%. Changes in cerebral blood flow in these clinical conditions were similarly detected by the two methods but ΔZp underestimated the magnitude of the change in comparison with CBF∞ and its accuracy was insufficient to allow conclusions about the magnitude of small changes in cerebral blood flow in individual infants.

[1]  O. Pryds,et al.  Intravenous 133Xe clearance in preterm neonates with respiratory distress. Internal validation of CBF infinity as a measure of global cerebral blood flow. , 1988, Scandinavian journal of clinical and laboratory investigation.

[2]  G. Greisen,et al.  Cerebral Blood Flow, PaCO2 Changes, and Visual Evoked Potentials in Mechanically Ventilated, Preterm Infants , 1987, Acta paediatrica Scandinavica.

[3]  L. Archer,et al.  Controlled Hypercapnia and Neonatal Cerebral Artery Doppler Ultrasound Waveforms , 1986, Pediatric Research.

[4]  G. Greisen,et al.  Cerebral blood food in preterm infants during the first week of life , 1986 .

[5]  B. C. Penney,et al.  Theory and cardiac applications of electrical impedance measurements. , 1986, Critical reviews in biomedical engineering.

[6]  K. Costeloe,et al.  A Comparison between Electrical Impedance and Strain Gauge Plethysmography for the Study of Cerebral Blood Flow in the Newborn , 1984, Pediatric Research.

[7]  L. Tarassenko,et al.  CEREBRAL HAEMODYNAMICS IN NEWBORN BABIES STUDIED BY ELECTRICAL IMPEDANCE Preliminary Results , 1983, Acta paediatrica Scandinavica. Supplement.

[8]  F. Cowan,et al.  An evaluation of the plethysmographic method of measuring cranial blood flow in the new‐born infant. , 1983, The Journal of physiology.

[9]  H. Thompson,et al.  Regional Cerebral Blood Flow Estimated by 133Xenon Inhalation , 1975 .

[10]  J. Jacquy,et al.  Cerebral blood flow and quantitative rheoencephalography. , 1974, Electroencephalography and clinical neurophysiology.

[11]  J M Van de Water,et al.  Application of bioelectric impedance to the measurement of arterial flow. , 1973, The Journal of surgical research.

[12]  D. Hadjiev Impedance methods for investigation of cerebral circulation. , 1972, Progress in brain research.

[13]  R. Patterson,et al.  Impedance cardiography as a noninvasive means to monitor cardiac function. , 1970, JAAMI : journal of the Association for the Advancement of Medical Instrumentation.

[14]  P. Scheinberg,et al.  Basic studies in rheoencephalography , 1967, Neurology.