A2-piece six-axis force/torque sensor capable of measuring loads applied to tools of complex shapes

Measuring forces and torques applied to tools of unconventional shapes can be challenging due to difficulties in connecting commercially available force/torque sensors. We propose an innovative, customizable six-axis force/torque sensor which can be clamped around a tool or end-effector to minimize the proximity between tool tip and sensor structure. The sensor is fabricated using 3d printing technology and consists of two pieces which together form an 8-legged Stewart platform. Each leg is designed as a cantilever beam to allow for a measurable displacement under an external load. The displacements of the legs are measured with 8 light intensity-based optoelectronic sensors, which exhibit high sensitivities and low noise levels without the need for external amplification circuitry. A customized printed circuit board and peripheral hardware are proposed to allow for efficient analog-to-digital conversion of the force/torque measurement. A calibration process is proposed which makes use ofa commercial ATI Mini40 sensor and custom hardware to allow for fast calibration routines. Finally, the calibrated sensor design is compared to the ATI Mini40 sensor by measuring sequences of forces and torques, and the maximum errors of force/torque components ($F_{x},\ F_{y},\ F_{\mathrm{z}},\ M_{x},\ M_{y},\ M_{\mathrm{z}}$) are 16.3%, 20.0%, 27.5%, 20.5%, 21.6%, 14.9% respectively.

[1]  Xinjuan Chen,et al.  Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity , 2013, Sensors.

[2]  Ashitava Ghosal,et al.  A force–torque sensor based on a Stewart Platform in a near-singular configuration , 2004 .

[3]  Min Li,et al.  Intra-operative tumour localisation in robot-assisted minimally invasive surgery : a review , 2015 .

[4]  You Zhou,et al.  ARMAR-6: A Collaborative Humanoid Robot for Industrial Environments , 2018, 2018 IEEE-RAS 18th International Conference on Humanoid Robots (Humanoids).

[5]  Clara J. Pacheco,et al.  A Noncontact Force Sensor Based on a Fiber Bragg Grating and Its Application for Corrosion Measurement , 2013, Sensors.

[6]  Kaspar Althoefer,et al.  Multi-Axis Force/Torque Sensor Based on Simply-Supported Beam and Optoelectronics , 2016, Sensors.

[7]  Danna Zhou,et al.  d. , 1934, Microbial pathogenesis.

[9]  Kim F. Nimon,et al.  Interpreting Multiple Linear Regression: A Guidebook of Variable Importance , 2012 .

[10]  Kaspar Althoefer,et al.  Three-Axis Fiber-Optic Body Force Sensor for Flexible Manipulators , 2016, IEEE Sensors Journal.

[11]  Paolo Dario,et al.  Effective emotional expressions with expression humanoid robot WE-4RII: integration of humanoid robot hand RCH-1 , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[12]  Mahmud Iwan,et al.  Implementation of Industrial Robot for Painting Applications , 2012 .

[13]  Robert Haslinger,et al.  A fiberoptic force-torque-sensor for minimally invasive robotic surgery , 2013, 2013 IEEE International Conference on Robotics and Automation.

[14]  Jung-Hoon Kim,et al.  Shape optimization of a mechanically decoupled six-axis force/torque sensor , 2014 .

[15]  Jung-Hoon Kim,et al.  Multi-Axis Force-Torque Sensors for Measuring Zero-Moment Point in Humanoid Robots: A Review , 2020, IEEE Sensors Journal.

[16]  Bernhard Kübler,et al.  Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[17]  Paolo Dario,et al.  Effective Emotional Expressions with Emotion Expression Humanoid Robot WE-4 RII-Integration of Humanoid Robot Hand RCH-1 - , 2004 .

[18]  Han-Pang Huang,et al.  Virtual Impedance Control for Safe Human-Robot Interaction , 2016, J. Intell. Robotic Syst..

[19]  Jian S. Dai,et al.  A six-component contact force measurement device based on the Stewart platform , 2000 .

[20]  Zhao Yanzheng,et al.  Research of the Localization of Restaurant Service Robot , 2010 .

[21]  T. A. Dwarakanath,et al.  Implementation of Stewart platform based force-torque sensor , 1999, Proceedings. 1999 IEEE/SICE/RSJ. International Conference on Multisensor Fusion and Integration for Intelligent Systems. MFI'99 (Cat. No.99TH8480).

[22]  A. Bernardino,et al.  The Power of a Handshake in Human-Robot Interactions , 2018 .

[23]  Kaspar Althoefer,et al.  Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound. , 2019, Journal of visualized experiments : JoVE.

[24]  V. Galatenko,et al.  Instrumental Mechanoreceptoric Palpation in Gastrointestinal Surgery , 2017, Minimally invasive surgery.

[25]  Yongsheng Zhao,et al.  A 3-D printed redundant six-component force sensor with eight parallel limbs , 2016 .

[26]  A. Schweikard,et al.  Calibration of Force/Torque and Acceleration for an Independent Safety Layer in Medical Robotic Systems , 2012 .

[27]  Atsuo Takanishi,et al.  Development of a Humorous Humanoid Robot Capable of Quick-and-Wide Arm Motion , 2016, IEEE Robotics and Automation Letters.

[28]  S. Sugiyama,et al.  Silicon Piezoresistive Six-Degree of Freedom Micro Force-Moment Sensor , 2004 .