Evaluation of Elevated Mean Pulmonary Arterial Pressure Based on Magnetic Resonance 4D Velocity Mapping: Comparison of Visualization Techniques

Purpose Three-dimensional (3D) magnetic resonance phase contrast imaging (PC-MRI) allows non-invasive diagnosis of pulmonary hypertension (PH) and estimation of elevated mean pulmonary arterial pressure (mPAP) based on vortical motion of blood in the main pulmonary artery. The purpose of the present study was to compare the presence and duration of PH-associated vortices derived from different flow visualization techniques with special respect to their performance for non-invasive assessment of elevated mPAP and diagnosis of PH. Methods Fifty patients with suspected PH (23 patients with and 27 without PH) were investigated by right heart catheterization and time-resolved PC-MRI of the main pulmonary artery. PC-MRI data were visualized with dedicated prototype software, providing 3D vector, multi-planar reformatted (MPR) 2D vector, streamline, and particle trace representation of flow patterns. Persistence of PH-associated vortical blood flow (tvortex) was evaluated with all visualization techniques. Dependencies of tvortex on visualization techniques were analyzed by means of correlation and receiver operating characteristic (ROC) curve analysis. Results tvortex values from 3D vector visualization correlated strongly with those from other visualization techniques (r = 0.98, 0.98 and 0.97 for MPR, streamline and particle trace visualization, respectively). Areas under ROC curves for diagnosis of PH based on tvortex did not differ significantly and were 0.998 for 3D vector, MPR vector and particle trace visualization and 0.999 for streamline visualization. Correlations between elevated mPAP and tvortex in patients with PH were r = 0.96, 0.93, 0.95 and 0.92 for 3D vector, MPR vector, streamline and particle trace visualization, respectively. Corresponding standard deviations from the linear regression lines ranged between 3 and 4 mmHg. Conclusion 3D vector, MPR vector, streamline as well as particle trace visualization of time-resolved 3D PC-MRI data of the main pulmonary artery can be employed for accurate vortex-based diagnosis of PH and estimation of elevated mPAP.

[1]  M. Alley,et al.  Time-Resolved 3-Dimensional Velocity Mapping in the Thoracic Aorta: Visualization of 3-Directional Blood Flow Patterns in Healthy Volunteers and Patients , 2004, Journal of computer assisted tomography.

[2]  H. Oertel Dynamics of Fluid Flow , 2010 .

[3]  Michael Markl,et al.  Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla , 2012, European Radiology.

[4]  R. Mohiaddin,et al.  Cardiovascular magnetic resonance in pulmonary hypertension , 2012, Journal of Cardiovascular Magnetic Resonance.

[5]  T. Ebbers,et al.  Particle trace visualization of intracardiac flow using time‐resolved 3D phase contrast MRI , 1999, Magnetic resonance in medicine.

[6]  Michael Markl,et al.  Aortic Hemodynamics in Patients With and Without Repair of Aortic Coarctation: In Vivo Analysis by 4D Flow-Sensitive Magnetic Resonance Imaging , 2011, Investigative radiology.

[7]  Richard D. White,et al.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. , 2010, Circulation.

[8]  M. Buonocore,et al.  Helical-shaped streamlines do not represent helical flow. , 2010, Radiology.

[9]  David L. Kao,et al.  Strategy for seeding 3D streamlines , 2005, VIS 05. IEEE Visualization, 2005..

[10]  Min Chen,et al.  Over Two Decades of Integration‐Based, Geometric Flow Visualization , 2010, Comput. Graph. Forum.

[11]  H. Oertel Prandtl's essentials of fluid mechanics , 2004 .

[12]  Horst Olschewski,et al.  Magnetic Resonance–Derived 3-Dimensional Blood Flow Patterns in the Main Pulmonary Artery as a Marker of Pulmonary Hypertension and a Measure of Elevated Mean Pulmonary Arterial Pressure , 2008, Circulation. Cardiovascular imaging.

[13]  Bob Laramee Feature Extraction and Visualization of Flow Fields , 2002 .

[14]  M H Buonocore,et al.  Visualizing blood flow patterns using streamlines, arrows, and particle paths , 1998, Magnetic resonance in medicine.

[15]  P J Kilner,et al.  Visualization of Flow by Vector Analysis of Multidirectional Cine MR Velocity Mapping , 1994, Journal of computer assisted tomography.

[16]  Pablo Irarrazaval,et al.  Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mapping. , 2013, Magnetic resonance imaging.

[17]  M. Alley,et al.  Bicuspid Aortic Valve : Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns 1 , 2010 .

[18]  Richard Frayne,et al.  Visualizing three‐dimensional flow with simulated streamlines and three‐dimensional phase‐contrast MR imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[19]  N J Pelc,et al.  Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.

[20]  M. Jolly,et al.  A Novel 4 D Flow Tool for Comprehensive Blood Flow Analysis , 2011 .

[21]  Scott B Reeder,et al.  4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot , 2012, Journal of Cardiovascular Magnetic Resonance.

[22]  Horst Olschewski,et al.  Guidelines on diagnosis and treatment of pulmonary arterial hypertension. The Task Force on Diagnosis and Treatment of Pulmonary Arterial Hypertension of the European Society of Cardiology. , 2004, European heart journal.

[23]  Kenneth I. Joy,et al.  Analysis of Time-Dependent Flow-Sensitive PC-MRI Data , 2012, IEEE Transactions on Visualization and Computer Graphics.

[24]  A. Yoganathan,et al.  Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging. , 2012, The Journal of thoracic and cardiovascular surgery.

[25]  N. Pelc,et al.  Comparison of cerebral artery blood flow measurements with gated cine and ungated phase‐contrast techniques , 1993, Journal of magnetic resonance imaging : JMRI.

[26]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.