Analysis and reduction of EMI conducted by a PWM inverter-fed AC motor drive system having long power cables

This paper analyzes conducted EMI generated by a PWM inverter-fed induction motor drive system. It is shown experimentally and analytically that resonant phenomena in a high-frequency range beyond a dominant resonant frequency are originated from the behavior of power cables as a distributed-constant circuit. Spectra of common-mode and differential-mode currents are simulated by means of introducing a distributed-constant model of the power cables, which consists of a 20-step ladder circuit. As a result, it is also shown that these resonances can be damped out by a single common-mode transformer (CMT) and three differential-mode filters (DMFs), both of which have been proposed by the authors.