Measurement of specimen‐induced aberrations of biological samples using phase stepping interferometry

Confocal or multiphoton microscopes, which deliver optical sections and three‐dimensional (3D) images of thick specimens, are widely used in biology. These techniques, however, are sensitive to aberrations that may originate from the refractive index structure of the specimen itself. The aberrations cause reduced signal intensity and the 3D resolution of the instrument is compromised. It has been suggested to correct for aberrations in confocal microscopes using adaptive optics. In order to define the design specifications for such adaptive optics systems, one has to know the amount of aberrations present for typical applications such as with biological samples. We have built a phase stepping interferometer microscope that directly measures the aberration of the wavefront. The modal content of the wavefront is extracted by employing Zernike mode decomposition. Results for typical biological specimens are presented. It was found for all samples investigated that higher order Zernike modes give only a small contribution to the overall aberration. Therefore, these higher order modes can be neglected in future adaptive optics sensing and correction schemes implemented into confocal or multiphoton microscopes, leading to more efficient designs.

[1]  R. Noll Zernike polynomials and atmospheric turbulence , 1976 .

[2]  Wilson,et al.  New modal wave-front sensor: a theoretical analysis , 2000, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  S. Hell,et al.  Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index , 1993 .

[4]  J. Hardy,et al.  Adaptive Optics for Astronomical Telescopes , 1998 .

[5]  T. Wilson,et al.  Adaptive aberration correction in a confocal microscope , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[6]  C. Sheppard,et al.  Theory and practice of scanning optical microscopy , 1984 .

[7]  O. Albert,et al.  Adaptive correction of depth‐induced aberrations in multiphoton scanning microscopy using a deformable mirror , 2002, Journal of microscopy.

[8]  S. Kawata,et al.  Adaptive aberration correction in a two‐photon microscope , 2000, Journal of microscopy.

[9]  R. Shack,et al.  History and principles of Shack-Hartmann wavefront sensing. , 2001, Journal of refractive surgery.

[10]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[11]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.

[12]  Tony Wilson,et al.  The effect of aberrations on the axial response of confocal imaging systems , 1989 .

[13]  T. Wilson,et al.  Aberration correction for confocal imaging in refractive‐index‐mismatched media , 1998 .