Technical Note: In silico and experimental evaluation of two leaf‐fitting algorithms for MLC tracking based on exposure error and plan complexity

PURPOSE Multileaf collimator (MLC) tracking is being clinically pioneered to continuously compensate for thoracic and pelvic motion during radiotherapy. The purpose of this work was to characterize the performance of two MLC leaf-fitting algorithms, direct optimization and piecewise optimization, for real-time motion compensation with different plan complexity and tumor trajectories. METHODS To test the algorithms, both in silico and phantom experiments were performed. The phantom experiments were performed on a Trilogy Varian linac and a HexaMotion programmable motion platform. High and low modulation VMAT plans for lung and prostate cancer cases were used along with eight patient-measured organ-specific trajectories. For both MLC leaf-fitting algorithms, the plans were run with their corresponding patient trajectories. To compare algorithms, the average exposure errors, i.e., the difference in shape between ideal and fitted MLC leaves by the algorithm, plan complexity and system latency of each experiment were calculated. RESULTS Comparison of exposure errors for the in silico and phantom experiments showed minor differences between the two algorithms. The average exposure errors for in silico experiments with low/high plan complexity were 0.66/0.88 cm2 for direct optimization and 0.66/0.88 cm2 for piecewise optimization, respectively. The average exposure errors for the phantom experiments with low/high plan complexity were 0.73/1.02 cm2 for direct and 0.73/1.02 cm2 for piecewise optimization, respectively. The measured latency for the direct optimization was 226 ± 10 ms and for the piecewise algorithm was 228 ± 10 ms. In silico and phantom exposure errors quantified for each treatment plan demonstrated that the exposure errors from the high plan complexity (0.96 cm2 mean, 2.88 cm2 95% percentile) were all significantly different from the low plan complexity (0.70 cm2 mean, 2.18 cm2 95% percentile) (P < 0.001, two-tailed, Mann-Whitney statistical test). CONCLUSIONS The comparison between the two leaf-fitting algorithms demonstrated no significant differences in exposure errors, neither in silico nor with phantom experiments. This study revealed that plan complexity impacts the overall exposure errors significantly more than the difference between the algorithms.

[1]  Gregor Ochsner,et al.  Development and evaluation of a prototype tracking system using the treatment couch. , 2014, Medical physics.

[2]  Lu Wang,et al.  Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Paul Keall,et al.  Online prediction of respiratory motion: multidimensional processing with low-dimensional feature learning , 2010, Physics in medicine and biology.

[4]  Paul Keall,et al.  Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems. , 2010, Medical physics.

[5]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[6]  Paul J Keall,et al.  The impact of leaf width and plan complexity on DMLC tracking of prostate intensity modulated arc therapy. , 2013, Medical physics.

[7]  P Keall,et al.  SU-G-JeP1-05: Clinical Impact of MLC Tracking for Lung SABR. , 2016, Medical physics.

[8]  Patrick A Kupelian,et al.  Observations on real-time prostate gland motion using electromagnetic tracking. , 2008, International journal of radiation oncology, biology, physics.

[9]  Nico Buls,et al.  Initial assessment of tumor tracking with a gimbaled linac system in clinical circumstances: a patient simulation study. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  Yoshihiro Takai,et al.  A phase II study on stereotactic body radiotherapy for stage I non-small cell lung cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  Uwe Oelfke,et al.  Electromagnetic real-time tumor position monitoring and dynamic multileaf collimator tracking using a Siemens 160 MLC: geometric and dosimetric accuracy of an integrated system. , 2011, International journal of radiation oncology, biology, physics.

[12]  Paul J Keall,et al.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator. , 2014, Medical physics.

[13]  Per Rugaard Poulsen,et al.  An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch‐MLC tracking , 2017, Medical physics.

[14]  R. V. van Klaveren,et al.  Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Paul Keall,et al.  Image-based dynamic multileaf collimator tracking of moving targets during intensity-modulated arc therapy. , 2012, International journal of radiation oncology, biology, physics.

[16]  Paul J Keall,et al.  The first clinical implementation of electromagnetic transponder-guided MLC tracking. , 2014, Medical physics.

[17]  Paul Keall,et al.  Dynamic multileaf collimator control for motion adaptive radiotherapy: An optimization approach , 2011, 2011 IEEE Power Engineering and Automation Conference.

[18]  Cai Grau,et al.  Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking. , 2013, Medical physics.

[19]  Ghulam Murtaza,et al.  Volumetric modulated arc therapy with dynamic collimator rotation for improved multileaf collimator tracking of the prostate. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  Paul J. Keall,et al.  Experimentally Validated Simulator of Dynamic MLC Tracking Treatments: A Tool for Tracking QA , 2013 .

[21]  Martin F Fast,et al.  Dynamic tumor tracking using the Elekta Agility MLC. , 2014, Medical physics.

[22]  Mitsuhiro Nakamura,et al.  Intrafractional tracking accuracy in infrared marker-based hybrid dynamic tumour-tracking irradiation with a gimballed linac. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  Paul J Keall,et al.  An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients , 2008, Physics in medicine and biology.

[24]  Paul Keall,et al.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery. , 2012, Medical physics.

[25]  Paul J Keall,et al.  Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial. , 2015, International journal of radiation oncology, biology, physics.

[26]  Herbert Cattell,et al.  Electromagnetic-guided dynamic multileaf collimator tracking enables motion management for intensity-modulated arc therapy. , 2011, International journal of radiation oncology, biology, physics.

[27]  Herbert Cattell,et al.  Real-time dynamic MLC tracking for inversely optimized arc radiotherapy. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Uwe Oelfke,et al.  Real-time tumor tracking: automatic compensation of target motion using the Siemens 160 MLC. , 2010, Medical physics.

[29]  Lorenzo Livi,et al.  Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy. , 2013, Medical physics.

[30]  V. Gebski,et al.  Stereotactic prostate adaptive radiotherapy utilising kilovoltage intrafraction monitoring: the TROG 15.01 SPARK trial , 2017, BMC Cancer.

[31]  M J Murphy,et al.  The Cyberknife: a frameless robotic system for radiosurgery. , 1997, Stereotactic and functional neurosurgery.

[32]  Kristijan Macek,et al.  Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator. , 2016, Medical physics.

[33]  S Webb,et al.  MLC tracking for Elekta VMAT: a modelling study , 2011, Physics in medicine and biology.

[34]  Dan Ruan,et al.  Fast leaf-fitting with generalized underdose/overdose constraints for real-time MLC tracking. , 2015, Medical physics.

[35]  S Webb,et al.  An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery , 2013, Physics in medicine and biology.