Intensive insulin therapy: enhanced Model Predictive Control algorithm versus standard care

ObjectiveTo investigate the effectiveness of an enhanced software Model Predictive Control (eMPC) algorithm for intravenous insulin infusion, targeted at tight glucose control in critically ill patients, over 72 h, in two intensive care units with different management protocols.DesignComparison with standard care in a two center open randomized clinical trial.SettingTwo adult intensive care units in University Hospitals.Patients and participantsThirty-four critically ill patients with hyperglycaemia (glucose >120 mg/dL) or already receiving insulin infusion.InterventionsPatients were randomized, within each ICU, to intravenous insulin infusion advised by eMPC algorithm or the ICU’s standard insulin infusion administration regimen.Measurements and resultsArterial glucose concentration was measured at study entry and when advised by eMPC or measured as part of standard care. Time-weighted average glucose concentrations in patients receiving eMPC advised insulin infusions were similar [104 mg/dL (5.8 mmol/L)] in both ICUs. eMPC advised glucose measurement interval was significantly different between ICUs (1.1 vs. 1.8 h, P < 0.01). The standard care insulin algorithms resulted in significantly different time-weighted average glucose concentrations between ICUs [128 vs. 99 mg/dL (7.1 vs. 5.5 mmol/L), P < 0.01].ConclusionsIn this feasibility study the eMPC algorithm provided similar, effective and safe tight glucose control over 72 h in critically ill patients in two different ICUs. Further development is required to reduce glucose sampling interval while maintaining a low risk of hypoglycaemia.

[1]  G. Van den Berghe How to compare adequacy of algorithms to control blood glucose in the intensive care unit? , 2004, Critical care.

[2]  Liu Xinbing,et al.  Intensive insulin therapy for the critically ill patients with stress hyperglycemia , 2008 .

[3]  S Andreassen,et al.  Model predictive glycaemic regulation in critical illness using insulin and nutrition input: a pilot study. , 2006, Medical engineering & physics.

[4]  Mathijs Vogelzang,et al.  Hyperglycaemic index as a tool to assess glucose control: a retrospective study , 2004, Critical care.

[5]  Mathijs Vogelzang,et al.  Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit , 2005, BMC Medical Informatics Decis. Mak..

[6]  G. Grunkemeier,et al.  Continuous insulin infusion reduces mortality in patients with diabetes undergoing coronary artery bypass grafting. , 2003, The Journal of thoracic and cardiovascular surgery.

[7]  M. Castellanos,et al.  Tight glycemic control in critically ill patients. , 2010, JAMA.

[8]  D. Tibboel,et al.  Effects of low-dose naloxone on opioid therapy in pediatric patients: a retrospective case-control study , 2006, Intensive Care Medicine.

[9]  Bruce W Bode,et al.  Glucommander: a computer-directed intravenous insulin system shown to be safe, simple, and effective in 120,618 h of operation. , 2005, Diabetes care.

[10]  M Schetz,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[11]  James Stephen Krinsley,et al.  Effect of an intensive glucose management protocol on the mortality of critically ill adult patients. , 2004, Mayo Clinic proceedings.

[12]  A. Thomas,et al.  Implementation of a tight glycaemic control protocol using a web‐based insulin dose calculator , 2005, Anaesthesia.

[13]  Roman Hovorka,et al.  Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients. , 2006, Diabetes care.

[14]  J. Lau,et al.  Insulin therapy and in-hospital mortality in critically ill patients: systematic review and meta-analysis of randomized controlled trials. , 2006, JPEN. Journal of parenteral and enteral nutrition.

[15]  Roman Hovorka,et al.  Closing the loop: the adicol experience. , 2004, Diabetes technology & therapeutics.

[16]  Miet Schetz,et al.  Outcome benefit of intensive insulin therapy in the critically ill: Insulin dose versus glycemic control* , 2003, Critical care medicine.

[17]  Scott K Aberegg,et al.  Intensive insulin therapy in the medical ICU. , 2006, The New England journal of medicine.

[18]  Paul Taylor,et al.  Research Paper: Use of a Computerized Guideline for Glucose Regulation in the Intensive Care Unit Improved Both Guideline Adherence and Glucose Regulation , 2004, J. Am. Medical Informatics Assoc..

[19]  R. Hovorka Continuous glucose monitoring and closed‐loop systems , 2006, Diabetic medicine : a journal of the British Diabetic Association.