Device for respiration activity measurement enables the determination of oxygen transfer rates of microbial cultures in shaken 96‐deepwell microtiter plates

Mini‐bioreactors with integrated online monitoring capabilities are well established in the early stages of process development. Mini‐bioreactors fulfil the demand for high‐throughput‐applications and a simultaneous reduction of material costs and total experimental time. One of the most essential online monitored parameters is the oxygen transfer rate (OTR). OTR‐monitoring allows fast characterization of bioprocesses and process transfer to larger scales. Currently, OTR‐monitoring on a small‐scale is limited to shake flasks and 48‐well microtiter plates (MTP). Especially, 96‐deepwell MTP are used for high‐throughput‐experiments during early‐stage bioprocess development. However, a device for OTR monitoring in 96‐deepwell MTP is still not available. To determine OTR values, the measurement of the gas composition in each well of a MTP is necessary. Therefore, a new micro(µ)‐scale Transfer rate Online Measurement device (µTOM) was developed. The µTOM includes 96 parallel oxygen‐sensitive sensors and a single robust sealing mechanism. Different organisms (Escherichia coli, Hansenula polymorpha, and Ustilago maydis) were cultivated in the µTOM. The measurement precision for 96 parallel cultivations was 0.21 mmol·L−1·h−1 (pooled standard deviation). In total, a more than 15‐fold increase in throughput and an up to a 50‐fold decrease in media consumption, compared with the shake flask RAMOS‐technology, was achieved using the µTOM for OTR‐monitoring.

[1]  Qingxiang Yang,et al.  High-throughput screening of lycopene-overproducing mutants of Blakeslea trispora by combining ARTP mutation with microtiter plate cultivation and transcriptional changes revealed by RNA-seq , 2020 .

[2]  H. Aoyagi,et al.  Analysis of porous breathable stopper and development of PID control for gas phase during shake-flask culture with microorganisms , 2020, Applied Microbiology and Biotechnology.

[3]  J. Büchs,et al.  Optimization of the Ames RAMOS test allows for a reproducible high-throughput mutagenicity test. , 2020, The Science of the total environment.

[4]  J. Büchs,et al.  Precultures grown under fed-batch conditions increase the reliability and reproducibility of high-throughput screening results. , 2019, Biotechnology journal.

[5]  J. Büchs,et al.  Shake flask methodology for assessing the influence of the maximum oxygen transfer capacity on 2,3-butanediol production , 2019, Microbial Cell Factories.

[6]  Y. Nakashima,et al.  Continuous cell culture monitoring using a compact microplate reader with a silicone optical technology-based spatial filter. , 2019, The Review of scientific instruments.

[7]  J. Büchs,et al.  Elucidation of auxotrophic deficiencies of Bacillus pumilus DSM 18097 to develop a defined minimal medium , 2018, Microbial Cell Factories.

[8]  J. Büchs,et al.  Parallel online determination of ethylene release rate by Shaken Parsley cell cultures using a modified RAMOS device , 2018, BMC Plant Biology.

[9]  Wolfgang Wiechert,et al.  Microbioreactor Systems for Accelerated Bioprocess Development , 2018, Biotechnology journal.

[10]  H. Ohtake,et al.  Online measurement of the respiratory activity in shake flasks enables the identification of cultivation phases and patterns indicating recombinant protein production in various Escherichia coli host strains , 2018, Biotechnology progress.

[11]  W. Wiechert,et al.  Fast and reliable strain characterization of Streptomyces lividans through micro‐scale cultivation , 2017, Biotechnology and bioengineering.

[12]  H. Aoyagi,et al.  Development of a circulation direct sampling and monitoring system for O2 and CO2 concentrations in the gas–liquid phases of shake-flask systems during microbial cell culture , 2017, AMB Express.

[13]  J. Büchs,et al.  Respiration activity monitoring system for any individual well of a 48-well microtiter plate , 2016, Journal of biological engineering.

[14]  J. Büchs,et al.  Correlation for the maximum oxygen transfer capacity in shake flasks for a wide range of operating conditions and for different culture media , 2016 .

[15]  Karl-Erich Jaeger,et al.  Exchange of single amino acids at different positions of a recombinant protein affects metabolic burden in Escherichia coli , 2015, Microbial Cell Factories.

[16]  Sven Hansen,et al.  Cross-section perimeter is a suitable parameter to describe the effects of different baffle geometries in shaken microtiter plates , 2014, Journal of biological engineering.

[17]  J. Büchs,et al.  Pitfalls in optical on-line monitoring for high-throughput screening of microbial systems , 2014, Microbial Cell Factories.

[18]  Stefan Schillberg,et al.  Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale , 2013, Journal of Biological Engineering.

[19]  J. Büchs,et al.  Development of a modified Respiration Activity Monitoring System for accurate and highly resolved measurement of respiration activity in shake flask fermentations , 2012, Journal of biological engineering.

[20]  Jochen Büchs,et al.  Power input correlation to characterize the hydrodynamics of cylindrical orbitally shaken bioreactors , 2012 .

[21]  J. Büchs,et al.  Advances in shaking technologies. , 2012, Trends in biotechnology.

[22]  Philipp M. Grande,et al.  Biomass pretreatment affects Ustilago maydis in producing itaconic acid , 2012, Microbial Cell Factories.

[23]  Frank Kensy,et al.  Scale-up from microtiter plate to laboratory fermenter: evaluation by online monitoring techniques of growth and protein expression in Escherichia coli and Hansenula polymorpha fermentations , 2009, Microbial cell factories.

[24]  Ashraf Amanullah,et al.  Twenty‐four well plate miniature bioreactor system as a scale‐down model for cell culture process development , 2009, Biotechnology and bioengineering.

[25]  I Klimant,et al.  Red light-excitable oxygen sensing materials based on platinum(II) and palladium(II) benzoporphyrins. , 2008, Analytical chemistry.

[26]  G J Lye,et al.  Scale‐up of Escherichia coli growth and recombinant protein expression conditions from microwell to laboratory and pilot scale based on matched kLa , 2008, Biotechnology and bioengineering.

[27]  Sebastian Hahn,et al.  An experimental comparison of respiration measuring techniques in fermenters and shake flasks: exhaust gas analyzer vs. RAMOS device vs. respirometer , 2007, Journal of Industrial Microbiology & Biotechnology.

[28]  Gary J. Lye,et al.  Modelling surface aeration rates in shaken microtitre plates using dimensionless groups , 2005 .

[29]  E. Racker History of the Pasteur effect and its pathobiology , 1974, Molecular and Cellular Biochemistry.

[30]  V. Passoth,et al.  Aerobic induction of respiro-fermentative growth by decreasing oxygen tensions in the respiratory yeast Pichia stipitis , 2005, Applied Microbiology and Biotechnology.

[31]  J. Büchs,et al.  Online respiration activity measurement (OTR, CTR, RQ) in shake flasks , 2004 .

[32]  Wouter A. Duetz,et al.  Oxygen transfer by orbital shaking of square vessels and deepwell microtiter plates of various dimensions , 2004 .

[33]  J. Büchs,et al.  Effect of oxygen supply on passaging, stabilising and screening of recombinant Hansenula polymorpha production strains in test tube cultures. , 2003, FEMS yeast research.

[34]  J. Büchs,et al.  Characterization of gas-liquid mass transfer phenomena in microtiter plates. , 2003, Biotechnology and bioengineering.

[35]  John M Woodley,et al.  Accelerated design of bioconversion processes using automated microscale processing techniques. , 2003, Trends in biotechnology.

[36]  M. Reuss,et al.  High-cell-density fermentation for production of L-N-carbamoylase using an expression system based on the Escherichia coli rhaBAD promoter. , 2001, Biotechnology and bioengineering.

[37]  J. Büchs,et al.  Device for sterile online measurement of the oxygen transfer rate in shaking flasks. , 2001, Biochemical engineering journal.

[38]  J Büchs,et al.  Introduction to advantages and problems of shaken cultures. , 2001, Biochemical engineering journal.

[39]  W. A. Scheffers,et al.  Effect of benzoic acid on metabolic fluxes in yeasts: A continuous‐culture study on the regulation of respiration and alcoholic fermentation , 1992, Yeast.

[40]  Max E. Lippitsch,et al.  Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier , 1988 .

[41]  Otto Stern,et al.  Über die abklingungszeit der fluoreszenz , 1919 .