Feed-forward compensation of surface potential in atomic force microscopy.

We introduce a feed-forward technique for lift-mode Kelvin probe force microscopy to minimize electrostatically induced errors in topography scans. Such errors typically occur when a grounded tip is scanned over a heterogeneous sample with differences in local work function or areas of local surface charging. To minimize electrostatic forces during the topography scan we bias the tip with the surface potential recorded in the previous Kelvin probe scan line. With this method we achieve an error free topography on samples with large variations in local surface potential. Compared to conventional tapping mode, we further observe a significant reduction of tip-induced surface charge modifications on charge patterns written in electret films.

[1]  Gary H. Bernstein,et al.  Apparent height in tapping mode of electrostatic force microscopy , 2006 .

[2]  Andreas Stemmer,et al.  Measuring and modifying the electric surface potential distribution on a nanometre scale : a powerful tool in science and technology , 1999 .

[3]  A. Stemmer,et al.  Charge writing on the nanometre scale in a fluorocarbon film , 2002 .

[4]  Joël Chevrier,et al.  Detection of electrostatic forces with an atomic force microscope: Analytical and experimental dynamic force curves in the nonlinear regime , 2003 .

[5]  A. Stemmer,et al.  Attaching silica nanoparticles from suspension onto surface charge patterns generated by a conductive atomic force microscope tip , 2001 .

[6]  A. Stemmer,et al.  Resolution and contrast in Kelvin probe force microscopy , 1998 .

[7]  Lukas M. Eng,et al.  Accuracy and resolution limits of Kelvin probe force microscopy , 2005 .

[8]  A. Stemmer,et al.  Practical aspects of Kelvin probe force microscopy , 1999 .

[9]  A. Stemmer,et al.  Compensating electrostatic forces by single-scan Kelvin probe force microscopy , 2007 .

[10]  M. Lux‐Steiner,et al.  Influence of uncompensated electrostatic force on height measurements in non-contact atomic force microscopy , 2004 .

[11]  M. Lux‐Steiner,et al.  Correct height measurement in noncontact atomic force microscopy. , 2003, Physical review letters.

[12]  J. Gavoille,et al.  Surface charges and adhesion measured by atomic force microscope influence on friction force , 2003 .

[13]  H. Kumar Wickramasinghe,et al.  High‐resolution capacitance measurement and potentiometry by force microscopy , 1988 .

[14]  H. K. Wickramasinghe,et al.  Kelvin probe force microscopy , 1991 .

[15]  J. Gómez‐Herrero,et al.  Electrostatic force gradient signal: resolution enhancement in electrostatic force microscopy and improved Kelvin probe microscopy , 2003 .

[16]  J. E. Stern,et al.  Deposition and imaging of localized charge on insulator surfaces using a force microscope , 1988 .