Parametric study and analytical characterization of the bolt–column (BC) joint for single-layer reticulated structures

Abstract The bolt–column (BC) joint, which can efficiently connect H, I and rectangular section members, is actually semi-rigid and of partial strength. The consideration of real semi-rigid behaviour can lead to a more accurate global analysis and, consequently, more optimized structures. In this paper a parametric analysis is conducted on the joint. A total of 341 models, divided into five series G1–G6, were analyzed. The main parameters affecting the rotational capacity and failure mode of the joint were considered in the finite element (FE) models. First, the optimal geometric parameters, such as the suitable thickness of the side plate and front plate, were obtained and discussed. Second, the mechanical behaviour of the joints under different static load conditions, including pure bending moment, eccentric pressure, eccentric tension, bending with a defined pressure and bending with a defined tension force, was investigated in detail. The theoretical equations and envelope curves for predicting the moment capacity of the joints under eccentric forces and bending with axial forces were established. Furthermore, based on the component methods in Eurocode 3 (EC3) (CEN, 2005) [1], a trilinear mathematical model for predicting the moment–rotation relationship of the joints was developed. The moment–rotation curves obtained by the mathematical model compare very satisfactorily with the experimental results.

[1]  Weiqing Liu,et al.  A component method for moment-resistant glulam beam–column connections with glued-in steel rods , 2016 .

[2]  Henning Agerskov HIGH-STRENGTH BOLTED CONNECTIONS SUBJECT TO PRYING , 1976 .

[3]  Shan Ren,et al.  Experimental and numerical research on a new semi-rigid joint for single-layer reticulated structures , 2016 .

[4]  Mark A. Bradford,et al.  Numerical simulation of steel pretensioned bolted end-plate connections of different types and details , 2008 .

[5]  J. M. Reinosa,et al.  Experimental and numerical analysis of three-dimensional semi-rigid steel joints under non-proportional loading , 2012 .

[6]  Florian M. Block,et al.  A Component Approach to Modelling Steelwork Connections in Fire: Behaviour of Column Webs in Compression , 2004 .

[7]  Paulo Vila Real,et al.  Post-limit stiffness and ductility of end-plate beam-to-column steel joints , 2002 .

[8]  M. R. Mohamadi-shooreh,et al.  Parametric analyses on the initial stiffness of flush end-plate splice connections using FEM , 2008 .

[9]  Frans S.K. Bijlaard,et al.  T-stub behavior under out-of-plane bending. II: Parametric study and analytical characterization , 2015 .

[10]  I. Puente,et al.  Experimental and analytical studies on the rotational stiffness of joints for single-layer structures , 2011 .

[11]  Shizhao Shen,et al.  Numerical analyses of semi-rigid joints subjected to bending with and without axial force , 2013 .

[12]  Khalifa S. Al-Jabri,et al.  Spring-stiffness model for flexible end-plate bare-steel joints in fire , 2005 .

[13]  Shizhao Shen,et al.  Experimental study of semi-rigid joint systems subjected to bending with and without axial force , 2012 .

[14]  Roberto T. Leon,et al.  Parametric analysis of steel bolted end plate connections using finite element modeling , 2005 .

[15]  Eduardo Bayo,et al.  An alternative design for internal and external semi-rigid composite joints. Part II: Finite element modelling and analytical study , 2008 .

[16]  Shiro Kato,et al.  Design procedure for large single-layer latticed domes. , 1993 .

[17]  Chanakya Arya,et al.  Eurocode 3: Design of steel structures , 2018, Design of Structural Elements.

[18]  Donald W. White,et al.  Refined 3D finite element modeling of partially-restrained connections including slip , 2002 .