An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices

Maintaining an acceptable indoor environmental quality (IEQ) for air-conditioned office buildings consumes a considerable amount of thermal energy. This study correlates thermal energy consumption with the overall occupant acceptance of IEQ in some air-conditioned offices. An empirical expression of an IEQ index associated with thermal comfort, indoor air quality, aural and visual comfort is used to benchmark the offices. Employing input parameters obtained from the building stocks of Hong Kong, the office portfolios regarding the thermal energy consumption and the IEQ index are determined by Monte Carlo simulations. In particular, an energy-to-acceptance ratio and an energy-to-IEQ improvement ratio are proposed to measure the performance of energy consumption for the IEQ in the air-conditioned offices. The ratios give the thermal energy consumption corresponding to a desirable percentage of IEQ acceptances and to an IEQ upgrade, respectively. The results showed a non-linear increasing trend of annual thermal energy consumption for IEQ improvement at the offices of higher IEQ benchmarks. The thermal energy consumption for visual comfort and indoor air quality would also be significant in these offices. This study provides useful information that incorporates the IEQ in air-conditioned offices into the development of performance evaluation measures for thermal energy consumption.

[1]  L. T. Wong,et al.  Survey on the air diffusion devices for air-conditioning systems in Hong Kong , 1998 .

[2]  Kwok-wai Mui,et al.  Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate , 2006 .

[3]  John Burnett,et al.  Lighting Quality Surveys in Office Premises , 2000 .

[4]  Wan Ki Chow,et al.  Energy impact of commercial-building envelopes in the sub-tropical climate , 1998 .

[5]  Gail Brager,et al.  Developing an adaptive model of thermal comfort and preference , 1998 .

[6]  Sai On Cheung,et al.  An analysis of electricity end-use in air-conditioned office buildings in Hong Kong , 2003 .

[7]  L. T. Wong,et al.  A method of assessing the acceptability of noise levels in air-conditioned offices , 2006 .

[8]  K. Mui,et al.  Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong , 2008 .

[9]  Povl Ole Fanger,et al.  Sensory pollution loads in six office buildings and a department store , 2004 .

[10]  R. Dear,et al.  Thermal adaptation in the built environment: a literature review , 1998 .

[11]  Joseph C. Lam,et al.  Regression analysis of high-rise fully air-conditioned office buildings , 1997 .

[12]  L. T. Wong,et al.  A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices , 2008 .

[13]  Philip C.H. Yu,et al.  A discussion on potentials of saving energy use for commercial buildings in Hong Kong , 2007 .

[14]  S. C. Sofuoglu,et al.  The Indoor Environmental Index and Its Relationship with Symptoms of Office Building Occupants , 2004, Journal of the Air & Waste Management Association.

[15]  Michael Yit Lin Chew,et al.  Building Grading Systems: A Review of the State-of-the-Art , 2008 .

[16]  L. T. Wong,et al.  An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates , 2007 .

[17]  Nai-Kong Fong,et al.  Bayesian adaptive comfort temperature (BACT) of air-conditioning system in subtropical climate , 2007 .

[18]  K. Mui,et al.  Neutral temperature in subtropical climates—A field survey in air-conditioned offices , 2007 .

[19]  L. T. Wong,et al.  Acceptable Illumination Levels for Office Occupants , 2006 .

[20]  Jennifer A. Veitch,et al.  Task Lighting Effects on Office Worker Satisfaction and Performance, and Energy Efficiency , 2005 .

[21]  K. Mui,et al.  Evaluation of the neutral criterion of indoor air quality for air-conditioned offices in subtropical climates , 2007 .

[22]  Joseph C. Lam,et al.  Outdoor design conditions for HVAC system design and energy estimation for buildings in Hong Kong , 1995 .

[23]  Knut Skyberg,et al.  The Effect of Cleaning on Dust and the Health of Office Workers: An Intervention Study , 2004, Epidemiology.

[24]  L. T. Wong,et al.  Modelling Transient Occupant Loads for Offices , 2006 .

[25]  L. T. Wong,et al.  An energy impact assessment of indoor air quality acceptance for air-conditioned offices , 2008 .

[26]  Francesco Martellotta,et al.  A new approach to assessing the performance of noise indices in buildings , 2003 .

[27]  Clarence E. Waters,et al.  VCP and UGR Glare Evaluation Systems: A Look Back and a Way Forward , 2005 .

[28]  Kurt Binder,et al.  Monte Carlo Simulation in Statistical Physics , 1992, Graduate Texts in Physics.

[29]  L. T. Wong,et al.  A statistical model for characterizing common air pollutants in air-conditioned offices , 2006 .

[30]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .