Impedimetric immunosensors based on the conjugated polymer PPV.

In the work reported here, we investigated the interaction between the semiconducting polymer MDMO-PPV and antibodies against the fluorescent dyes fluorescein isothiocyanate (FITC) and Cy5. The antibodies are adsorbed physically onto thin polymer films on gold electrodes, as seen in AFM images of these films. By tuning the antibody concentration, the contact angle of distilled water with the film can be made to vary between 95 degrees and 50 degrees, showing that different surface densities of antibody can be obtained. That these biosensor films specifically bind their antigenic fluorescent molecules from PBS buffer solution is demonstrated by confocal fluorescence microscopy. Specific antigen-antibody recognition is demonstrated by lack of cross-sensitivity between the two antibodies and their antigens. In a biosensor prototype based on differential impedance spectroscopy, these polymer films show a clear response to 1 ppb antigen solution, with a time constant of 2-3 min.

[1]  O. Sadik,et al.  Direct Electrochemical Immunosensor for Polychlorinated Biphenyls , 1998 .

[2]  Najm Nico Sommerdijk,et al.  Poly(3,4‐ethylenedioxythiophene)‐Based Glucose Biosensors , 2001 .

[3]  I. Willner,et al.  Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme Biosensors , 2003 .

[4]  Gaudenz Danuser,et al.  FRET or no FRET: a quantitative comparison. , 2003, Biophysical journal.

[5]  O A Sadik,et al.  Differential impedance spectroscopy for monitoring protein immobilization and antibody-antigen reactions. , 2002, Analytical chemistry.

[6]  L. Hermans,et al.  Nanoscaled interdigitated titanium electrodes for impedimetric biosensing , 2000 .

[7]  J. Jansen,et al.  Performance of subcutaneously implanted glucose sensors: a review. , 1998, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[8]  Peter Alfred Payne,et al.  Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing , 2001 .

[9]  G. Bazan,et al.  Fluorescein provides a resonance gate for FRET from conjugated polymers to DNA intercalated dyes. , 2004, Journal of the American Chemical Society.

[10]  Robert J Hamers,et al.  Frequency-dependent electrical detection of protein binding events. , 2004, The Analyst.

[11]  W. Schuhmann,et al.  Amperometric biosensors produced by immobilization of redox enzymes at polythiophene‐modified electrode surfaces , 1996 .

[12]  A. L. Adams,et al.  Adsorption of proteins out of plasma and solutions in narrow spaces , 1986 .

[13]  P. A. Fiorito,et al.  Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures , 2001 .

[14]  S. Refaey Electrochemical impedance studies on the electrochemical properties of poly(3-methylthiophene) in aqueous solutions , 2004 .

[15]  Dirk Vanderzande,et al.  A New Synthetic Route to a Soluble High Molecular Weight Precursor for Poly(p-phenylenevinylene) derivatives , 1995 .

[16]  P Vadgama,et al.  Reagentless biosensing using electrochemical impedance spectroscopy. , 2002, Bioelectrochemistry.

[17]  César Fernández-Sánchez,et al.  Quantitative impedimetric immunosensor for free and total prostate specific antigen based on a lateral flow assay format , 2004 .

[18]  J. W. Osborne,et al.  The adsorptive characteristics of proteins for polystyrene and their significance in solid-phase imunoassays. , 1980, Analytical biochemistry.

[19]  Christoph J. Brabec,et al.  A comparison between state-of-the-art ‘gilch’ and ‘sulphinyl’ synthesised MDMO-PPV/PCBM bulk hetero-junction solar cells , 2002 .

[20]  Ronn Andriessen,et al.  Disclosure of the nanostructure of MDMO-PPV:PCBM bulk hetero-junction organic solar cells by a combination of SPM and TEM , 2003 .