Multidirectional Gradient Neighbourhood-Weighted Image Sharpness Evaluation Algorithm

Aiming at the problem that the image sharpness evaluation algorithm in the photoelectric system has a slow speed in actual processing and is severely disturbed by noise, an improved image sharpness evaluation algorithm is proposed by combining multiscale decomposition tools and multidirectional gradient neighbourhood weighting. This paper applies non-subsampled shearlet transform (NSST) to perform multiscale transformation of the input images, obtaining high-frequency sub-band images and low-frequency sub-band images. In order to enhance the detection of the edge orientation of images, multidirectional gradient processing of the image matrix is added to each sub-band image. In addition, the weight corresponding to the current pixel is obtained by calculating the inverse ratio of the gradient of each direction and the distance of the center pixel. Through calculating the ratio of the gradient neighbourhood weighting operators of high-frequency sub-band images and low-frequency sub-band images, the image sharpness evaluation value can be acquired further. Moreover, the image sequence collected by a certain type of photoelectric system is selected as the image sequence of the noisy real environment for simulation experiments and compared with the current mainstream algorithms. Finally, the experimental draws a conclusion that compared with the mainstream evaluation algorithms, the evaluation results of the proposed method perform better in terms of steepness, sensitivity, and flat area fluctuation, it can better suppress noise and improve accuracy, and its running speed meets the basic requirements of the image sharpness evaluation algorithm.

[1]  Yixiong Liang,et al.  Learning to autofocus based on Gradient Boosting Machine for optical microscopy , 2019 .

[2]  N. Wong,et al.  Evaluation of the photovoltaic potential in built environment using spatial data captured by unmanned aerial vehicles , 2019, Energy Science & Engineering.

[3]  Y. Wang,et al.  Multiscale SAR image segmentation by combining curvelet transform and GMTRJ algorithms , 2019, Digit. Signal Process..

[4]  Nebojša M. Ralević,et al.  Fuzzy metric and its applications in removing the image noise , 2019, Soft Comput..

[5]  Weisi Lin,et al.  No-Reference and Robust Image Sharpness Evaluation Based on Multiscale Spatial and Spectral Features , 2017, IEEE Transactions on Multimedia.

[6]  J. Jiménez-Hoyuela,et al.  Hybrid imaging (SPECT/CT) in the evaluation and management of a patient with heterotopic calcification and hip prostheses , 2019, Revista Española de Medicina Nuclear e Imagen Molecular (English Edition).

[7]  Dinis Moreira,et al.  Automatic Focus Assessment on Dermoscopic Images Acquired with Smartphones , 2019, Sensors.

[8]  B. Duan,et al.  Spatiotemporal Characterizations of Spontaneously Beating Cardiomyocytes with Adaptive Reference Digital Image Correlation , 2019, Scientific Reports.

[9]  Yu Cheng,et al.  Quantum image scaling based on bilinear interpolation with arbitrary scaling ratio , 2019, Quantum Information Processing.

[10]  Zhenyu Li,et al.  Application research of digital image technology in graphic design , 2019, J. Vis. Commun. Image Represent..

[11]  Guofan Jin,et al.  Optical design of the freeform reflective imaging system with wide rectangular FOV and low F-number , 2019 .

[12]  R. Gosselin,et al.  Unmixing noisy co-registered spectrum images of multicomponent nanostructures , 2019, Scientific Reports.

[13]  Y. Kouno,et al.  Image quality evaluation of in-treatment four-dimensional cone-beam computed tomography in volumetric-modulated arc therapy for stereotactic body radiation therapy. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[15]  Keisuke Kondo,et al.  Development of a dynamic blood vessel phantom for evaluation of moving images , 2019, Journal of applied clinical medical physics.

[16]  Liting Yu,et al.  Technical note: A modified gamma evaluation method for dose distribution comparisons , 2019, Journal of applied clinical medical physics.