Measurement of nonuniform current density by magnetic resonance.

A noninvasive tissue current measurement technique and its use in measuring a nonuniform current density are described. This current density image is created by measuring the magnetic field arising from these currents and taking its curl. These magnetic fields are proportional to the phase component of a complex magnetic resonance image. Measurements of all three components of a quasistatic nonuniform current density in a phantom are described. Expected current density calculations from a numerical solution for the magnetic field which was created by the phantom are presented for comparison. The results of a numerical simulation of the experiment, which used this field solution and which included the effects of slice selection and sampling, are also presented. The experimental and simulated results are quantitatively compared. It is concluded that the principle source of systematic error was the finite slice thickness, which causes blurring of boundaries.

[1]  Mark Hedley,et al.  A new two‐dimensional phase unwrapping algorithm for MRI images , 1992, Magnetic resonance in medicine.

[2]  Greig C. Scott,et al.  Two-dimensional current density imaging , 1990 .

[3]  J. Juni,et al.  Measurement of hepatocellular function with deconvolutional analysis: application in the differential diagnosis of acute jaundice. , 1990, Radiology.

[4]  Robert E. Alvarez Biomagnetic Fourier Imaging , 1990 .

[5]  R E Alvarez Biomagnetic Fourier imaging [current density reconstruction]. , 1990, IEEE transactions on medical imaging.

[6]  N. G. Sepulveda,et al.  Using a magnetometer to image a two‐dimensional current distribution , 1989 .

[7]  M. Joy,et al.  In vivo detection of applied electric currents by magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[8]  B C Towe,et al.  Bioelectric current image reconstruction from magneto-acoustic measurements. , 1988, IEEE transactions on medical imaging.

[9]  D M Kramer,et al.  Signal-to-noise ratio and section thickness in two-dimensional versus three-dimensional Fourier transform MR imaging. , 1988, Radiology.

[10]  B N Cuffin The role of model and computational experiments in the biomagnetic inverse problem. , 1987, Physics in medicine and biology.

[11]  W. Dallas Fourier space solution to the magnetostatic imaging problem. , 1985, Applied optics.

[12]  Andrew A. Maudsley,et al.  Magnetic field measurement by NMR imaging , 1984 .

[13]  A. Caprihan Effect of Amplitude Modulation on Selective Excitation in NMR Imaging , 1983, IEEE Transactions on Medical Imaging.

[14]  K Itoh,et al.  Analysis of the phase unwrapping algorithm. , 1982, Applied optics.

[15]  M. Holz,et al.  NMR measurements of internal magnetic field gradients caused by the presence of an electric current in electrolyte solutions , 1980 .

[16]  P. Gerard,et al.  Hall effect in dilute electrolytes , 1976 .

[17]  D. Paris,et al.  Basic Electromagnetic Theory , 1969 .