Estimation of perfusion properties with MR Fingerprinting Arterial Spin Labeling.

In this study, the acquisition of ASL data and quantification of multiple hemodynamic parameters was explored using a Magnetic Resonance Fingerprinting (MRF) approach. A pseudo-continuous ASL labeling scheme was used with pseudo-randomized timings to acquire the MRF ASL data in a 2.5 min acquisition. A large dictionary of MRF ASL signals was generated by combining a wide range of physical and hemodynamic properties with the pseudo-random MRF ASL sequence and a two-compartment model. The acquired signals were matched to the dictionary to provide simultaneous quantification of cerebral blood flow, tissue time-to-peak, cerebral blood volume, arterial time-to-peak, B1, and T1. A study in seven healthy volunteers resulted in the following values across the population in grey matter (mean ± standard deviation): cerebral blood flow of 69.1 ± 6.1 ml/min/100 g, arterial time-to-peak of 1.5 ± 0.1 s, tissue time-to-peak of 1.5 ± 0.1 s, T1 of 1634 ms, cerebral blood volume of 0.0048 ± 0.0005. The CBF measurements were compared to standard pCASL CBF estimates using a one-compartment model, and a Bland-Altman analysis showed good agreement with a minor bias. Repeatability was tested in five volunteers in the same exam session, and no statistical difference was seen. In addition to this validation, the MRF ASL acquisition's sensitivity to the physical and physiological parameters of interest was studied numerically.

[1]  T. Mikkelsen,et al.  Quantitative Estimation of Permeability Surface-Area Product in Astroglial Brain Tumors Using Perfusion CT and Correlation with Histopathologic Grade , 2008, American Journal of Neuroradiology.

[2]  Whitney B. Pope,et al.  Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆ , 2013, NeuroImage: Clinical.

[3]  Sven Haller,et al.  Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications. , 2016, Radiology.

[4]  J. Detre,et al.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling , 2007, Magnetic resonance in medicine.

[5]  R B Buxton,et al.  A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging , 1998, Magnetic resonance in medicine.

[6]  Peter Jezzard,et al.  Modeling dispersion in arterial spin labeling: Validation using dynamic angiographic measurements , 2013, Magnetic resonance in medicine.

[7]  David C. Alsop,et al.  Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma1 , 2005 .

[8]  S Warach,et al.  A general kinetic model for quantitative perfusion imaging with arterial spin labeling , 1998, Magnetic resonance in medicine.

[9]  Tarik K Alkasab,et al.  Incidence of nephrogenic systemic fibrosis after adoption of restrictive gadolinium-based contrast agent guidelines. , 2011, Radiology.

[10]  Harald E. Möller,et al.  Mapping of arterial transit time by intravascular signal selection , 2014, NMR in biomedicine.

[11]  Gregory R. Lee,et al.  Quantification of perfusion fMRI using a numerical model of arterial spin labeling that accounts for dynamic transit time effects , 2005, Magnetic resonance in medicine.

[12]  Truman R Brown,et al.  Pseudo‐random arterial modulation (PRAM): A novel arterial spin labeling approach to measure flow and blood transit times , 2012, Journal of magnetic resonance imaging : JMRI.

[13]  Roger J Ordidge,et al.  In vivo hadamard encoded continuous arterial spin labeling (H‐CASL) , 2010, Magnetic resonance in medicine.

[14]  Daniel Gallichan,et al.  Modeling the effects of dispersion and pulsatility of blood flow in pulsed arterial spin labeling , 2008, Magnetic resonance in medicine.

[15]  Joseph A Maldjian,et al.  Clinical applications of arterial spin labeling , 2013, NMR in biomedicine.

[16]  J H Duyn,et al.  Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling , 2008, Magnetic resonance in medicine.

[17]  Serter Gumus,et al.  Estimation of single‐kidney glomerular filtration rate without exogenous contrast agent , 2014, Magnetic resonance in medicine.

[18]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[19]  Yong Chen,et al.  Multiscale reconstruction for MR fingerprinting , 2016, Magnetic resonance in medicine.

[20]  Jeffrey H Maki,et al.  Renovascular imaging in the NSF Era , 2009, Journal of magnetic resonance imaging : JMRI.

[21]  Weiying Dai,et al.  Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging , 2012, Magnetic resonance in medicine.

[22]  Ping Wang,et al.  Simultaneous measurement of cerebral blood flow and transit time with turbo dynamic arterial spin labeling (Turbo‐DASL): Application to functional studies , 2012, Magnetic resonance in medicine.

[23]  Hengyi Rao,et al.  Applications of arterial spin labeled MRI in the brain , 2012, Journal of magnetic resonance imaging : JMRI.

[24]  R B Buxton,et al.  Quantification of regional pulmonary blood flow using ASL‐FAIRER , 2006, Magnetic resonance in medicine.

[25]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[26]  T Sasaki,et al.  Perfusion Imaging of Brain Tumors Using Arterial Spin-Labeling: Correlation with Histopathologic Vascular Density , 2008, American Journal of Neuroradiology.

[27]  Donald S. Williams,et al.  Perfusion analysis using dynamic arterial spin labeling (DASL) , 1999, Magnetic resonance in medicine.

[28]  R. Kraft,et al.  Arterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts , 2008, American Journal of Neuroradiology.

[29]  Yufen Chen,et al.  Test–retest reliability of arterial spin labeling with common labeling strategies , 2011, Journal of magnetic resonance imaging : JMRI.

[30]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[31]  Donald S. Williams,et al.  Perfusion imaging , 1992, Magnetic resonance in medicine.

[32]  Vince Istvan Madai,et al.  Walsh‐ordered hadamard time‐encoded pseudocontinuous ASL (WH pCASL) , 2016, Magnetic resonance in medicine.

[33]  Hanzhang Lu,et al.  Multiparametric estimation of brain hemodynamics with MR fingerprinting ASL , 2017, Magnetic resonance in medicine.

[34]  Eidrees Ghariq,et al.  Time‐encoded pseudocontinuous arterial spin labeling: Basic properties and timing strategies for human applications , 2014, Magnetic resonance in medicine.

[35]  M. E. Moseley,et al.  MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain , 2014, NeuroImage.

[36]  Mark Bydder,et al.  SNR and functional sensitivity of BOLD and perfusion-based fMRI using arterial spin labeling with spiral SENSE at 3 T. , 2008, Magnetic resonance imaging.

[37]  J. Detre,et al.  Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling , 2000, Magnetic resonance in medicine.

[38]  J. Kucharczyk,et al.  Diffusion/perfusion MR imaging of acute cerebral ischemia , 1991, Magnetic resonance in medicine.

[39]  G. Zaharchuk,et al.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. , 2015, Magnetic resonance in medicine.

[40]  Eric C. Wong,et al.  Blind detection of vascular sources and territories using random vessel encoded arterial spin labeling , 2011, Magnetic Resonance Materials in Physics, Biology and Medicine.