Contrast settling in cerebral aneurysm angiography.

During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm.

[1]  A. Wakhloo,et al.  Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity , 1997, Annals of Biomedical Engineering.

[2]  Eric A Hoffman,et al.  Influence of gravity on radiographic contrast material-based measurements of regional blood flow distribution. , 2003, Academic radiology.

[3]  Ikuo Sugiyama,et al.  Structure of blood flow through a curved vessel with an aneurysm. , 1984, Biorheology.

[4]  A new method for assessment of changes in retinal blood flow. , 1997, Medical engineering & physics.

[5]  R S Lawson,et al.  Application of mathematical methods in dynamic nuclear medicine studies. , 1999, Physics in medicine and biology.

[6]  H. Meng,et al.  Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study. , 2004, Journal of neurosurgery.

[7]  Daniel R. Bednarek,et al.  Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent , 2004, SPIE Medical Imaging.

[8]  Chander Sadasivan,et al.  Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement. , 2002, AJNR. American journal of neuroradiology.

[9]  F Asakura,et al.  Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography. , 1998, AJNR. American journal of neuroradiology.

[10]  G. Geremia,et al.  Embolization of experimentally created aneurysms with intravascular stent devices. , 1992, AJNR. American journal of neuroradiology.

[11]  A. Wakhloo,et al.  Stents for intracranial aneurysms: the beginning of a new endovascular era? , 1998, Neurosurgery.

[12]  J Haberstroh,et al.  Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. , 1994, AJNR. American journal of neuroradiology.

[13]  L. Nelson Hopkins,et al.  Current techniques for endovascular treatment of intracranial aneurysms , 2001 .

[14]  O. Smedby Angiographic methods for the study of fluid mechanical factors in atherogenesis. , 1992, Acta radiologica. Supplementum.

[15]  M. Reiser,et al.  Pulmonary embolism: comprehensive diagnosis by using electron-beam CT for detection of emboli and assessment of pulmonary blood flow. , 2000, Radiology.

[16]  R. Close,et al.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature. , 2000, Medical physics.

[17]  Ciprian N Ionita,et al.  Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents , 2004, SPIE Medical Imaging.

[18]  M. Gounis,et al.  The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms , 2002, Neurological research.

[19]  T. Liou,et al.  Flowfields in lateral aneurysm models arising from parent vessels with different curvatures using PTV , 1997 .