Dosimetry of ionising radiation in modern radiation oncology

Dosimetry of ionising radiation is a well-established and mature branch of physical sciences with many applications in medicine and biology. In particular radiotherapy relies on dosimetry for optimisation of cancer treatment and avoidance of severe toxicity for patients. Several novel developments in radiotherapy have introduced new challenges for dosimetry with small and dynamically changing radiation fields being central to many of these applications such as stereotactic ablative body radiotherapy and intensity modulated radiation therapy. There is also an increasing awareness of low doses given to structures not in the target region and the associated risk of secondary cancer induction. Here accurate dosimetry is important not only for treatment optimisation but also for the generation of data that can inform radiation protection approaches in the future. The article introduces some of the challenges and highlights the interdependence of dosimetric calculations and measurements. Dosimetric concepts are explored in the context of six application fields: reference dosimetry, small fields, low dose out of field, in vivo dosimetry, brachytherapy and auditing of radiotherapy practice. Recent developments of dosimeters that can be used for these purposes are discussed using spatial resolution and number of dimensions for measurement as sorting criteria. While dosimetry is ever evolving to address the needs of advancing applications of radiation in medicine two fundamental issues remain: the accuracy of the measurement from a scientific perspective and the importance to link the measurement to a clinically relevant question. This review aims to provide an update on both of these.

[1]  B. Rhein,et al.  Radiobiological Investigation of Dose-Rate Effects in Intensity-Modulated Radiation Therapy , 2005, Strahlentherapie und Onkologie.

[2]  A. Rosenfeld,et al.  MOSFET dosimeters: the role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields , 1995 .

[3]  Yoichi Watanabe,et al.  Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry. , 2004, Medical physics.

[4]  J. Lehmann,et al.  Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams. , 2014, Medical physics.

[5]  F. Ballester,et al.  Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations. , 2014, Medical physics.

[6]  C. Thieke,et al.  DAVID—a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques , 2006, Physics in medicine and biology.

[7]  A. Micke,et al.  Multichannel film dosimetry with nonuniformity correction. , 2011, Medical physics.

[8]  B. Ferreira,et al.  Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry , 2009, Physics in medicine and biology.

[9]  M. Petasecca,et al.  Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT). , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  J C Rosenwald,et al.  ICRP publication 112. A report of preventing accidental exposures from new external beam radiation therapy technologies. , 2009, Annals of the ICRP.

[11]  Marcel van Herk,et al.  Impact of daily anatomical changes on EPID-based in vivo dosimetry of VMAT treatments of head-and-neck cancer. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  B. McCurdy,et al.  The influence of a novel transmission detector on 6 MV x-ray beam characteristics. , 2009, Physics in medicine and biology.

[13]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[14]  W A Beckham,et al.  Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam. , 1994, Physics in medicine and biology.

[15]  Pedro Andreo,et al.  The IAEA/WHO TLD postal dose quality audits for radiotherapy: a perspective of dosimetry practices at hospitals in developing countries. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  M van Herk,et al.  New method to obtain the midplane dose using portal in vivo dosimetry. , 1998, International journal of radiation oncology, biology, physics.

[17]  O. Senkesen,et al.  Comparison of 3D dose distributions for HDR 192Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system. , 2014, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[18]  N Papanikolaou,et al.  Calculation of portal dose using the convolution/superposition method. , 1996, Medical physics.

[19]  B J Mijnheer,et al.  In vivo dosimetry during external photon beam radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[20]  Tao Ju,et al.  Does the γ dose distribution comparison technique default to the distance to agreement test in clinical dose distributions? , 2013, Medical physics.

[21]  Murty S. Goddu,et al.  Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA , 2012, Journal of applied clinical medical physics.

[22]  Luc Beaulieu,et al.  The collapsed cone algorithm for 192Ir dosimetry using phantom-size adaptive multiple-scatter point kernels , 2015, Physics in medicine and biology.

[23]  Natalka Suchowerska,et al.  Small field diode correction factors derived using an air core fibre optic scintillation dosimeter and EBT2 film , 2012, Physics in medicine and biology.

[24]  F. Verhaegen,et al.  Dose to tissue medium or water cavities as surrogate for the dose to cell nuclei at brachytherapy photon energies , 2012, Physics in medicine and biology.

[25]  J. Damilakis,et al.  Peripheral dose measurements for 6 and 18MV photon beams on a linear accelerator with multileaf collimator. , 2008, Medical physics.

[26]  G. Rikner,et al.  Patient dose measurements in photon fields by means of silicon semiconductor detectors. , 1987, Medical physics.

[27]  S. Korreman Motion in radiotherapy: photon therapy , 2012, Physics in medicine and biology.

[28]  J Seuntjens,et al.  On the correction, perturbation and modification of small field detectors in relative dosimetry , 2014, Physics in medicine and biology.

[29]  Nilendu Gupta,et al.  Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA , 2014, Journal of applied clinical medical physics.

[30]  S. Dieterich,et al.  Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors. , 2011, Medical physics.

[31]  Todd Pawlicki,et al.  The systematic application of quality measures and process control in clinical radiation oncology. , 2012, Seminars in radiation oncology.

[32]  E. Hall,et al.  Intensity-modulated radiation therapy, protons, and the risk of second cancers. , 2006, International journal of radiation oncology, biology, physics.

[34]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[35]  N. Suchowerska,et al.  Scintillation dosimeter arrays using air core light guides: simulation and experiment , 2010, Physics in medicine and biology.

[36]  P. Hall,et al.  Risk of ischemic heart disease in women after radiotherapy for breast cancer. , 2013, The New England journal of medicine.

[37]  T. Kairn,et al.  Field size consistency of nominally matched linacs , 2015, Australasian Physical & Engineering Sciences in Medicine.

[38]  M Petasecca,et al.  A silicon strip detector dose magnifying glass for IMRT dosimetry. , 2010, Medical physics.

[39]  J. Cygler,et al.  First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning—new issues for clinical consideration , 2006, Physics in medicine and biology.

[40]  T Kairn,et al.  Monte Carlo-based diode design for correction-less small field dosimetry , 2013, Physics in medicine and biology.

[41]  M. Oldham,et al.  Optical-CT gel-dosimetry I: basic investigations. , 2003, Medical physics.

[42]  D P Fontenla,et al.  Uncertainty of calibrations at the accredited dosimetry calibration laboratories. , 1997, Medical physics.

[43]  D. Thwaites,et al.  Vorsprung durch Technik: evolution, implementation, QA and safety of new technology in radiotherapy. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[44]  Aapm A protocol for the determination of absorbed dose from high-energy photon and electron beams. , 1983, Medical physics.

[45]  R. Crilly,et al.  Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector , 2014, Journal of applied clinical medical physics.

[46]  D. Followill,et al.  IMRT credentialing for prospective trials using institutional virtual phantoms: results of a joint European Organization for the Research and Treatment of Cancer and Radiological Physics Center project , 2014, Radiation oncology.

[47]  P. Jursinic,et al.  In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material. , 2011, Medical physics.

[48]  Marco Marinelli,et al.  Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams. , 2012, Medical physics.

[49]  Jan-Jakob Sonke,et al.  A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments. , 2009, Medical physics.

[50]  Jan Seuntjens,et al.  Detector dose response in megavoltage small photon beams. I. Theoretical concepts. , 2015, Medical physics.

[51]  Joseph O Deasy,et al.  Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): an introduction to the scientific issues. , 2010, International journal of radiation oncology, biology, physics.

[52]  J. Purdy,et al.  Comparison of peripheral dose from image-guided radiation therapy (IGRT) using kV cone beam CT to intensity-modulated radiation therapy (IMRT). , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[53]  B R L Siebert,et al.  Uncertainty in radiation dosimetry: basic concepts and methods. , 2006, Radiation protection dosimetry.

[54]  M van Herk,et al.  Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[55]  A. Stevenson,et al.  High spatial resolution dosimetric response maps for radiotherapy ionization chambers measured using kilovoltage synchrotron radiation , 2015, Physics in medicine and biology.

[56]  M. Clift,et al.  Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams. , 2000, Physics in medicine and biology.

[57]  Todsaporn Fuangrod,et al.  First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions. , 2015, International journal of radiation oncology, biology, physics.

[58]  M. V. van Herk,et al.  Automatic in vivo portal dosimetry of all treatments , 2013, Physics in medicine and biology.

[59]  M. Zaider,et al.  Elements of microdosimetry. , 1991, Medical Physics (Lancaster).

[60]  T Kron,et al.  A novel methodology for 3D deformable dosimetry. , 2012, Medical physics.

[61]  Martin A Ebert,et al.  A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[62]  N Shandala,et al.  Scope of radiological protection control measures. , 2007, Annals of the ICRP.

[63]  D. Schardt,et al.  Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions , 2014, Physics in medicine and biology.

[64]  I. Das,et al.  Small fields: nonequilibrium radiation dosimetry. , 2007, Medical physics.

[65]  I. Aubineau-Lanièce,et al.  Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source. , 2013, Medical physics.

[66]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[67]  Indira Madani,et al.  Evidence behind use of intensity-modulated radiotherapy: a systematic review of comparative clinical studies. , 2008, The Lancet. Oncology.

[68]  T Kron,et al.  Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment. , 1994, Australasian physical & engineering sciences in medicine.

[69]  Ke Sheng,et al.  3D dose verification using tomotherapy CT detector array. , 2012, International journal of radiation oncology, biology, physics.

[70]  Dietrich Harder,et al.  The dose-area product, a new parameter for the dosimetry of narrow photon beams. , 2006, Zeitschrift fur medizinische Physik.

[71]  J. Seuntjens,et al.  On charged particle equilibrium violation in external photon fields. , 2012, Medical physics.

[72]  E. Hall,et al.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT. , 2003, International journal of radiation oncology, biology, physics.

[73]  Tommy Knöös,et al.  Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses. , 2011, Zeitschrift fur medizinische Physik.

[74]  C. De Wagter,et al.  The value of the LA48 linear ion chamber array for characterization of intensity-modulated beams. , 2001, Physics in medicine and biology.

[75]  G. Steel,et al.  Basic Clinical Radiobiology , 1997 .

[76]  D. S. Davis,et al.  Comparison of electron beam characteristics from multiple accelerators. , 2004, International journal of radiation oncology, biology, physics.

[77]  S. Duane,et al.  A portable calorimeter for measuring absorbed dose in the radiotherapy clinic. , 2000, Physics in Medicine and Biology.

[78]  Frank Verhaegen,et al.  The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources. , 2011, Medical physics.

[79]  J. Seuntjens,et al.  Development of a graphite probe calorimeter for absolute clinical dosimetry. , 2013, Medical physics.

[80]  K. Mohammadi,et al.  Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations , 2014, Journal of medical physics.

[81]  F. Nüsslin,et al.  A diamond detector in the dosimetry of high-energy electron and photon beams. , 1999, Physics in medicine and biology.

[82]  Harald Paganetti,et al.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction , 2008, Physics in medicine and biology.

[83]  M. V. van Herk,et al.  Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method. , 2006, Medical physics.

[84]  P. Chiovati,et al.  Dose to the skin in helical tomotherapy: results of in vivo measurements with radiochromic films. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[85]  A. Niemierko,et al.  Secondary Carcinogenesis in Patients Treated with Radiation: A Review of Data on Radiation-Induced Cancers in Human, Non-human Primate, Canine and Rodent Subjects , 2007, Radiation research.

[86]  P. Carrasco,et al.  Characterization of the Exradin W1 scintillator for use in radiotherapy. , 2014, Medical physics.

[87]  Robert J. Shalek,et al.  Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures , 1977 .

[88]  N. Yagi,et al.  A method of dosimetry for synchrotron microbeam radiation therapy using radiochromic films of different sensitivity , 2008, Physics in medicine and biology.

[89]  Christos Antypas,et al.  Performance evaluation of a CyberKnife® G4 image-guided robotic stereotactic radiosurgery system , 2008, Physics in medicine and biology.

[90]  Michael L. Taylor,et al.  Assessment of out-of-field doses in radiotherapy of brain lesions in children. , 2011, International journal of radiation oncology, biology, physics.

[91]  W. Butler,et al.  Erratum: Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations (Medical Physics (2004) 31 (633-674)) , 2004 .

[92]  R. Pandey,et al.  Biodosimetry using chromosome aberrations in human lymphocytes. , 2007, Radiation protection dosimetry.

[93]  Benjamin E Nelms,et al.  Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. , 2011, Medical physics.

[94]  R. Bristow,et al.  Biodosimetry using radiation-induced micronuclei in skin fibroblasts , 2011, International journal of radiation biology.

[95]  P. Jursinic,et al.  In vivo measurements for high dose rate brachytherapy with optically stimulated luminescent dosimeters. , 2013, Medical physics.

[96]  M. Tubiana Can we reduce the incidence of second primary malignancies occurring after radiotherapy? A critical review. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[97]  David S Followill,et al.  Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms. , 2007, Medical physics.

[98]  Natalka Suchowerska,et al.  Over-response of synthetic microDiamond detectors in small radiation fields , 2014, Physics in medicine and biology.

[99]  M. Bulsara,et al.  Dosimetric intercomparison for multicenter clinical trials using a patient-based anatomic pelvic phantom. , 2011, Medical physics.

[100]  Philippe Lambin,et al.  A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images. , 2006, Medical physics.

[101]  J. Williamson,et al.  Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation. , 2012, Medical physics.

[102]  F. Gómez,et al.  A new active method for the measurement of slow-neutron fluence in modern radiotherapy treatment rooms , 2010, Physics in medicine and biology.

[103]  L. Olsson,et al.  8th International Conference on 3D Radiation Dosimetry (IC3DDose) , 2015 .

[104]  D. G. Lewis,et al.  Full forward Monte Carlo calculation of portal dose from MLC collimated treatment beams. , 2004, Physics in medicine and biology.

[105]  Research on quality and safety: what are we missing? , 2015, International journal of radiation oncology, biology, physics.

[106]  Ross Berbeco,et al.  Management of the interplay effect when using dynamic MLC sequences to treat moving targets. , 2008, Medical physics.

[107]  Dietrich Harder,et al.  Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width , 2007, Physics in medicine and biology.

[108]  J. Pouliot,et al.  Miniature scintillating detector for small field radiation therapy. , 1999, Medical physics.

[109]  T Kairn,et al.  A practical and theoretical definition of very small field size for radiotherapy output factor measurements. , 2014, Medical physics.

[110]  G. Hartmann,et al.  Estimation of neutron-equivalent dose in organs of patients undergoing radiotherapy by the use of a novel online digital detector , 2012, Physics in medicine and biology.

[111]  S Webb,et al.  Intensity-modulated radiation therapy (IMRT): a clinical reality for cancer treatment, "any fool can understand this". The 2004 Silvanus Thompson Memorial Lecture. , 2005, The British journal of radiology.

[112]  P Andreo,et al.  Configuration of the electron transport algorithm of PENELOPE to simulate ion chambers , 2006, Physics in medicine and biology.

[113]  S. Doran,et al.  Establishing the suitability of quantitative optical CT microscopy of PRESAGE® radiochromic dosimeters for the verification of synchrotron microbeam therapy , 2013, Physics in medicine and biology.

[114]  J. Dempsey,et al.  Evaluation of the gamma dose distribution comparison method. , 2003, Medical physics.

[115]  L. Myrianthopoulos,et al.  In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18MV IMRT. , 2006, Medical physics.

[116]  B. Nilsson,et al.  Characteristics of silicon diodes as patient dosemeters in external radiation therapy. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[117]  Pejman Rowshanfarzad,et al.  Gantry-angle resolved VMAT pretreatment verification using EPID image prediction. , 2013, Medical physics.

[118]  D. Followill,et al.  Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer. , 2013, Medical physics.

[119]  Firas Mourtada,et al.  Commissioning of a grid-based Boltzmann solver for cervical cancer brachytherapy treatment planning with shielded colpostats. , 2013, Brachytherapy.

[120]  A. Nahum,et al.  An EGS4 Monte Carlo examination of general cavity theory. , 1997, Physics in medicine and biology.

[121]  Tanya Kairn,et al.  Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry , 2013, Australasian Physical & Engineering Sciences in Medicine.

[122]  Effect of lung and target density on small-field dose coverage and PTV definition. , 2015, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[123]  H. Garnica-Garza Microdosimetry of X-ray-irradiated gold nanoparticles. , 2013, Radiation protection dosimetry.

[124]  Steve B. Jiang,et al.  Measurement of the interplay effect in lung IMRT treatment using EDR2 films , 2006, Journal of applied clinical medical physics.

[125]  J. Williamson,et al.  Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. , 2004 .

[126]  M. Lauterbach,et al.  Energy deposition of electrons in low-, medium- and high-Z material: Comparison of the Monte Carlo transport code EGS4 with experiment , 1999 .

[127]  T R Mackie,et al.  History of tomotherapy , 2006, Physics in medicine and biology.

[128]  S. Blake,et al.  Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy. , 2013, Medical physics.

[129]  J. Battista,et al.  Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter. , 1998, Medical physics.

[130]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[131]  Savino Cilla,et al.  In vivo dosimetry by an aSi-based EPID. , 2006, Medical physics.

[132]  N. Klassen,et al.  Water calorimetry for radiation dosimetry. , 1996, Physics in medicine and biology.

[133]  David S Followill,et al.  Independent Evaluations of IMRT through the Use of an Anthropomorphic Phantom , 2006, Technology in cancer research & treatment.

[134]  E Brian Butler,et al.  Versatility of the Novalis System to Deliver Image-Guided Stereotactic Body Radiation Therapy (SBRT) for Various Anatomical Sites , 2007, Technology in cancer research & treatment.

[135]  F. H. Attix Introduction to Radiological Physics and Radiation Dosimetry , 1991 .

[136]  D. Jaffray,et al.  An integral quality monitoring system for real-time verification of intensity modulated radiation therapy. , 2009, Medical physics.

[137]  R D Franich,et al.  Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation. , 2013, Radiation protection dosimetry.

[138]  P. Greer,et al.  Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry. , 2010, Medical physics.

[139]  M. L. Roy,et al.  A new single crystal diamond dosimeter for small beam: comparison with different commercial active detectors , 2013, Physics in medicine and biology.

[140]  C-M Ma,et al.  Dose specification for radiation therapy: dose to water or dose to medium? , 2011, Physics in medicine and biology.

[141]  E. Bezak,et al.  Out-of-Field Neutron and Leakage Photon Exposures and the Associated Risk of Second Cancers in High-Energy Photon Radiotherapy: Current Status , 2011, Radiation research.

[142]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[143]  T. Zhu,et al.  Performance evaluation of a diode array for enhanced dynamic wedge dosimetry. , 1997, Medical physics.

[144]  G. Rikner,et al.  Effects of radiation damage on p-type silicon detectors , 1983 .

[145]  L. Anderson,et al.  Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 , 1995 .

[146]  Benjamin E Nelms,et al.  Statistical variability and confidence intervals for planar dose QA pass rates. , 2011, Medical physics.

[147]  M. Smith,et al.  Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry''. , 2003, Physics in medicine and biology.

[148]  J. Gore,et al.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel. , 1996, Physics in medicine and biology.

[149]  Zdenka Kuncic,et al.  A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment. , 2013, Medical physics.

[150]  R. Pötter,et al.  GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[151]  Ionization chamber volume determination and quality assurance using micro-CT imaging. , 2008, Physics in medicine and biology.

[152]  A Moutsatsos,et al.  On the implementation of a recently proposed dosimetric formalism to a robotic radiosurgery system. , 2010, Medical physics.

[153]  J. Chow,et al.  Variations of lung density and geometry on inhomogeneity correction algorithms: A Monte Carlo dosimetric evaluation. , 2009, Medical physics.

[154]  Frank Verhaegen,et al.  Time dependent pre-treatment EPID dosimetry for standard and FFF VMAT , 2014, Physics in medicine and biology.

[155]  E G Yukihara,et al.  Optically stimulated luminescence (OSL) dosimetry in medicine , 2008, Physics in medicine and biology.

[156]  M. V. van Herk,et al.  Dosimetric characteristics of a liquid-filled electronic portal imaging device. , 1995, International journal of radiation oncology, biology, physics.

[157]  Xiaoqin Jiang,et al.  Evaluation of the ArcCHECK QA system for IMRT and VMAT verification. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[158]  Eric C Ford,et al.  A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy. , 2015, Medical physics.

[159]  M van Herk,et al.  Catching errors with in vivo EPID dosimetry. , 2010, Medical physics.

[160]  Anders Ahnesjö,et al.  Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy. , 2008, Medical physics.

[161]  J Cygler,et al.  GafChromic MD-55: investigated as a precision dosimeter. , 1997, Medical physics.

[162]  Suzanne L Wolden,et al.  Prediction of In Vivo Radiation Dose Status in Radiotherapy Patients using Ex Vivo and In Vivo Gene Expression Signatures , 2011, Radiation research.

[163]  Tomas Kron,et al.  The 16th Solid State Dosimetry Conference (SSD16) , 2011 .

[164]  M. V. van Herk,et al.  Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT. , 2007, International journal of radiation oncology, biology, physics.

[165]  Francisco Clemente‐Gutiérrez,et al.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric‐modulated arc therapy techniques , 2015, Journal of applied clinical medical physics.

[166]  R. Mohan,et al.  Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations. , 2000, Physics in medicine and biology.

[167]  M. Oldham,et al.  Optical-CT gel-dosimetry. II: Optical artifacts and geometrical distortion. , 2004, Medical physics.

[168]  T. Kron,et al.  Adaptive radiotherapy for bladder cancer reduces integral dose despite daily volumetric imaging. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[169]  J. Sempau,et al.  Chamber-quality factors in 60Co for three plane-parallel chambers for the dosimetry of electrons, protons and heavier charged particles: PENELOPE Monte Carlo simulations. , 2008, Physics in medicine and biology.

[170]  Luc Beaulieu,et al.  The evolution of brachytherapy treatment planning. , 2009, Medical physics.

[171]  J. Seuntjens,et al.  A new formalism for reference dosimetry of small and nonstandard fields. , 2008, Medical physics.

[172]  K. Shin,et al.  Radiation-induced cancers from modern radiotherapy techniques: intensity-modulated radiotherapy versus proton therapy. , 2010, International journal of radiation oncology, biology, physics.

[173]  A G Visser,et al.  Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation. , 1998, Physics in medicine and biology.

[174]  James L Bedford,et al.  Evaluation of the Delta4 phantom for IMRT and VMAT verification , 2009, Physics in medicine and biology.

[175]  S Cora,et al.  Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations. , 2011, Medical physics.

[176]  D Harder,et al.  Performance parameters of a liquid filled ionization chamber array. , 2013, Medical physics.

[177]  E. Hall,et al.  Radiobiology for the radiologist , 1973 .

[178]  D. Waterhouse,et al.  Lack of backscatter factor measurements in HDR applications with MOSkins , 2011, Australasian Physical & Engineering Sciences in Medicine.

[179]  D. Rogers,et al.  AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. , 1999, Medical physics.

[180]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[181]  Paul Z Y Liu,et al.  On the measurement of dose in-air for small radiation fields: choice of mini-phantom material , 2015, Physics in medicine and biology.

[182]  P. Lambin,et al.  A global calibration model for a-Si EPIDs used for transit dosimetry. , 2007, Medical physics.

[183]  David M. Rocke,et al.  Dosimetry for Quantitative Analysis of the Effects of Low-Dose Ionizing Radiation in Radiation Therapy Patients , 2006, Radiation research.

[184]  Tomas Kron,et al.  Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom. , 2002, International journal of radiation oncology, biology, physics.

[185]  Harald Paganetti,et al.  Dose to water versus dose to medium in proton beam therapy , 2009, Physics in medicine and biology.

[186]  U. Schneider,et al.  Measurements of the neutron dose equivalent for various radiation qualities, treatment machines and delivery techniques in radiation therapy , 2014, Physics in medicine and biology.

[187]  J. Gore,et al.  Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. , 1984, Physics in medicine and biology.

[188]  C. Reft The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams. , 2009, Medical physics.

[189]  David S Followill,et al.  Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials. , 2008, International journal of radiation oncology, biology, physics.

[190]  Avraham Eisbruch,et al.  Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group. , 2005, International journal of radiation oncology, biology, physics.

[191]  D. Followill,et al.  Angular dependence of the nanoDot OSL dosimeter. , 2011, Medical physics.

[192]  J. Kapatoes,et al.  On the accuracy and effectiveness of dose reconstruction for tomotherapy. , 2001, Physics in medicine and biology.

[193]  Stine Korreman,et al.  The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[194]  Hugo Palmans,et al.  On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry. , 2016, Physics in medicine and biology.

[195]  C. De Wagter,et al.  Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry , 2007, Physics in medicine and biology.

[196]  E Pantelis,et al.  Dosimetric accuracy of a deterministic radiation transport based (192)Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models. , 2012, Medical physics.

[197]  The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry. , 2011, Medical physics.

[198]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[199]  S Derreumaux,et al.  Lessons from recent accidents in radiation therapy in France. , 2008, Radiation protection dosimetry.

[200]  Luca Cozzi,et al.  Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media , 2011, Radiation oncology.

[201]  Response to "Comment on 'Characterization of the Exradin W1 scintillator for use in radiotherapy' " [Med. Phys. 42, 297-304 (2015)]. , 2015, Medical physics.

[202]  A Haworth,et al.  Source position verification and dosimetry in HDR brachytherapy using an EPID. , 2013, Medical physics.

[203]  X Allen Li,et al.  Respiration induced heart motion and indications of gated delivery for left-sided breast irradiation. , 2012, International journal of radiation oncology, biology, physics.

[204]  M. V. van Herk,et al.  Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification. , 2006, Medical physics.

[205]  Jan Seuntjens,et al.  Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects. , 2015, Medical physics.

[206]  Myonggeun Yoon,et al.  Feasibility study on the verification of actual beam delivery in a treatment room using EPID transit dosimetry , 2014, Radiation oncology.

[207]  Zdenka Kuncic,et al.  The water equivalence of solid phantoms for low energy photon beams. , 2010, Medical physics.

[208]  Firas Mourtada,et al.  Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams , 2010, Physics in medicine and biology.

[209]  D. Rogers Fifty years of Monte Carlo simulations for medical physics , 2006, Physics in medicine and biology.

[210]  M. Oldham,et al.  Polymer gel dosimetry. , 2010, Physics in medicine and biology.

[211]  B M C McCurdy,et al.  Model-based prediction of portal dose images during patient treatment. , 2013, Medical physics.

[212]  T. Liamsuwan,et al.  Microdosimetry of proton and carbon ions. , 2014, Medical physics.

[213]  J. Dempsey,et al.  New water equivalent liquid scintillation solutions for 3D dosimetry. , 2000, Medical physics.

[214]  Tomas Kron,et al.  The Australian Clinical Dosimetry Service: a commentary on the first 18 months , 2012, Australasian Physical & Engineering Sciences in Medicine.

[215]  Icrp Chapters 3 and 4 , 2007 .

[216]  K. Trott,et al.  The ANDANTE project: a multidisciplinary approach to neutron RBE. , 2015, Radiation protection dosimetry.

[217]  S. McKeever,et al.  Near-real-time radiotherapy dosimetry using optically stimulated luminescence of Al2O3:C: mathematical models and preliminary results. , 2005, Medical physics.

[218]  L. Grimaldi,et al.  Radiation-induced cardiac damage in early left breast cancer patients: risk factors, biological mechanisms, radiobiology, and dosimetric constraints. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[219]  J. Seuntjens,et al.  Measuring neutron spectra in radiotherapy using the nested neutron spectrometer. , 2015, Medical physics.

[220]  Peter B Greer,et al.  Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm. , 2015, Medical physics.

[221]  Andrea Molineu,et al.  The Radiological Physics Center's standard dataset for small field size output factors , 2012, Journal of applied clinical medical physics.

[222]  D Flühs,et al.  Direct reading measurement of absorbed dose with plastic scintillators--the general concept and applications to ophthalmic plaque dosimetry. , 1996, Medical physics.

[223]  A. Kowalski,et al.  Measurement of radiation dose delivered to breast tissue during mantle field irradiation for Hodgkin's disease. , 1998, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[224]  Louis Archambault,et al.  Water-equivalent dosimeter array for small-field external beam radiotherapy. , 2007, Medical physics.

[225]  Savino Cilla,et al.  Application of a practical method for the isocenter point in vivo dosimetry by a transit signal , 2007, Physics in medicine and biology.

[226]  Pedro Andreo,et al.  Dose to ‘water-like’ media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate , 2015, Physics in medicine and biology.

[227]  Tomas Kron,et al.  Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters. , 2014, Medical physics.

[228]  Yves De Deene,et al.  On the validity of 3D polymer gel dosimetry: III. MRI-related error sources , 2013, Physics in medicine and biology.

[229]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[230]  V. De Coste,et al.  A novel synthetic single crystal diamond device for in vivo dosimetry. , 2015, Medical physics.

[231]  Ryan P Manger,et al.  Failure mode and effects analysis and fault tree analysis of surface image guided cranial radiosurgery. , 2015, Medical physics.

[232]  N Suchowerska,et al.  Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide , 2008, Physics in medicine and biology.

[233]  Panayiotis Mavroidis,et al.  Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy. , 2014, Medical physics.

[234]  L. Holloway,et al.  Advances in kilovoltage x-ray beam dosimetry , 2014, Physics in medicine and biology.

[235]  S. Klevenhagen Physics and Dosimetry of Therapy Electron Beams , 1993 .

[236]  S. Seltzer,et al.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams. , 2014, Medical physics.

[237]  Suresh Senan,et al.  Dosimetric impact of interplay effect on RapidArc lung stereotactic treatment delivery. , 2011, International journal of radiation oncology, biology, physics.

[238]  R. Nath,et al.  In vivo neutron dosimetry during high-energy Bremsstrahlung radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[239]  R J Watts Evaluation of a diode detector array for use as a linear accelerator QC device. , 1998, Medical physics.

[240]  Tomas Kron,et al.  A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom. , 2014, Medical physics.

[241]  Michael L. Taylor,et al.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy , 2011, Journal of medical physics.

[242]  M. Anton,et al.  Difference in the relative response of the alanine dosimeter to megavoltage x-ray and electron beams , 2013, Physics in medicine and biology.

[243]  Joao Seco,et al.  Review on the characteristics of radiation detectors for dosimetry and imaging , 2014, Physics in medicine and biology.

[244]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[245]  Christof Baltes,et al.  Evaluation of the Machine Performance Check application for TrueBeam Linac , 2015, Radiation oncology.

[246]  C. De Wagter,et al.  Three dimensional radiation dosimetry in lung-equivalent regions by use of a radiation sensitive gel foam: proof of principle. , 2006, Medical physics.

[247]  S. Rustgi Application of a diamond detector to brachytherapy dosimetry. , 1998, Physics in medicine and biology.

[248]  K. Chytyk,et al.  Comprehensive fluence model for absolute portal dose image prediction. , 2009, Medical physics.

[249]  S. Altuwaijri,et al.  In vivo surface dose measurement using GafChromic film dosimetry in breast cancer radiotherapy: comparison of 7-field IMRT, tangential IMRT and tangential 3D-CRT , 2014, Radiation oncology.

[250]  P. Johnston,et al.  The influence of field size on stopping‐power ratios in‐ and out‐of‐field: quantitative data for the BrainLAB m3 micro‐multileaf collimator , 2012, Journal of applied clinical medical physics.

[251]  Vitali Moiseenko,et al.  In vitro study of cell survival following dynamic MLC intensity-modulated radiation therapy dose delivery. , 2007, Medical physics.

[252]  Josep M Martí-Climent,et al.  A method for multichannel dosimetry with EBT3 radiochromic films. , 2014, Medical physics.

[253]  Jan-Jakob Sonke,et al.  3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[254]  Qiuwen Wu,et al.  Independent verification of gantry angle for pre-treatment VMAT QA using EPID , 2012, Physics in medicine and biology.

[255]  C J Moore,et al.  Quantitative comparison of 3D and 2.5D gamma analysis: introducing gamma angle histograms , 2013, Physics in medicine and biology.

[256]  D. Kuban,et al.  The calculated risk of fatal secondary malignancies from intensity-modulated radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[257]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[258]  L. Holloway,et al.  Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy. , 2015, Medical physics.

[259]  P. Johnston,et al.  Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter. , 2014, Medical physics.

[260]  D. Townsend Multimodality imaging of structure and function , 2008, Physics in medicine and biology.

[261]  W vanElmpt,et al.  Point/Counterpoint. EPID dosimetry must soon become an essential component of IMRT quality assurance. , 2009 .