Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT Systems

Compact SPECT systems with cadmium zinc telluride (CZT) solid-state detectors with improved energy resolution and shorter acquisition times have recently been introduced. These systems have, however, different energy characteristics compared to NaI(Tl) crystal-based cameras; therefore, a need exists to develop new simulation models for these cameras. We modeled the charge transport within the CZT detectors for a GE Discovery 530c/570c SPECT system with multiple pinhole collimators employing the SIMIND Monte Carlo program and validated simulations against measurements. The incomplete charge collection between the anode and cathode in the pixilated CZT was modeled with the Hecht equation. The simulation also included charge-sharing effects across pixels due to physical interactions and charge diffusion. To validate our CZT-model, 99mTc and 123I point sources and a 201Tl line source were acquired and measured. Measured energy spectra were compared with simulated energy spectra. The Monte Carlo simulated energy spectra agreed well with the experimental measurements within the photopeak, overestimated the k-edge x-ray escape peaks of cadmium and telluride, and slightly underestimated the remainder of the tail. Comparisons of system sensitivity and spatial resolution were also conducted for an array of point source locations with results showing excellent agreement. Lastly, to demonstrate a clinically realistic case, a simulation of an anthropomorphic phantom with a cardiac insert and an inferior defect was performed. Simulated projections were processed using the GE Xeleris software confirming the accuracy of the SIMIND geometry. We conclude that it is feasible to simulate the GE Discovery 530c/570c SPECT system using the SIMIND code.

[1]  M. Ljungberg,et al.  A new collimator simulation in SIMIND based on the Delta-Scattering technique , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[2]  W. Shockley Currents to Conductors Induced by a Moving Point Charge , 1938 .

[3]  Jim Patton,et al.  A Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera , 2009, Journal of Nuclear Medicine.

[4]  C. Bai,et al.  Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imaging , 2008, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[5]  G J Hademenos,et al.  Comparison of four scatter correction methods using Monte Carlo simulated source distributions. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Michael Ljungberg,et al.  Monte Carlo Calculation in Nuclear Medicine: Applications in Diagnostic Imaging , 2012 .

[7]  S. Ramo Currents Induced by Electron Motion , 1939, Proceedings of the IRE.

[8]  E. Gordon DePuey,et al.  Advances in SPECT camera software and hardware: Currently available and new on the horizon , 2012, Journal of Nuclear Cardiology.

[9]  Leonid Tsukerman,et al.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[10]  R C Lanza,et al.  Development and validation of a Monte Carlo simulation of photon transport in an Anger camera. , 1990, IEEE transactions on medical imaging.

[11]  Faezeh Atri,et al.  Original Article , 2008 .

[12]  Michael Ljungberg,et al.  Simple Monte Carlo based scatter compensation for SPECT , 2010 .

[13]  Guido Germano,et al.  Advances in technical aspects of myocardial perfusion SPECT imaging , 2009, Journal of Nuclear Cardiology.

[14]  J. Stehli,et al.  Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese Patients , 2012, The Journal of Nuclear Medicine.

[15]  A. Einstein Über die von der molekularkinetischen Theorie der Wärme geforderte Bewegung von in ruhenden Flüssigkeiten suspendierten Teilchen [AdP 17, 549 (1905)] , 2005, Annalen der Physik.

[16]  Michael A. King,et al.  Monte Carlo Calculation in Nuclear Medicine: Applications in Diagnostic Imaging - Second Edition , 2012 .

[17]  Forrest B. Brown,et al.  Advances in the development and verification of MCNP5 and MCNP6 , 2011 .

[18]  D. Berman,et al.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction. , 1998, Circulation.

[19]  Michael Ljungberg,et al.  SIMIND scatter estimation: Experimental verification , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[20]  J. H. Hubbell,et al.  XCOM: Photon cross sections on a personal computer , 1987 .

[21]  D. Wehe,et al.  Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[22]  Stefan Thurner,et al.  Anomalous diffusion in view of Einstein's 1905 theory of Brownian motion , 2005 .

[23]  D. Berman,et al.  Recent technologic advances in nuclear cardiology , 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[24]  D. Berman,et al.  Solid-State SPECT technology: fast and furious , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[25]  L. Verger,et al.  Charge sharing on monolithic CdZnTe gamma-ray detectors: A simulation study , 2006 .

[26]  T. Ruddy,et al.  Cross-talk correction for dual-isotope imaging with a dedicated cardiac SPECT camera , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[27]  U. Fano Ionization Yield of Radiations. II. The Fluctuations of the Number of Ions , 1947 .

[28]  Respiratory gating for a stationary dedicated cardiac SPECT system , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[29]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2012 update: a report from the American Heart Association. , 2012, Circulation.

[30]  M. Ljungberg The Monte Carlo Method applied in Nuclear Medicine Dosimetry , 2012 .

[31]  Tadayuki Takahashi,et al.  Characterization of CdTe/CdZnTe detectors , 2001 .

[32]  D. Freedman,et al.  On the histogram as a density estimator:L2 theory , 1981 .

[33]  H. B. Barber,et al.  Charge transport in arrays of semiconductor gamma-ray detectors. , 1995, Physical review letters.

[34]  B. Hutton,et al.  Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology , 2009, Physics in medicine and biology.

[35]  S Stute,et al.  GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy , 2011, Physics in medicine and biology.

[36]  G. Knoll Radiation detection and measurement , 1979 .

[37]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.

[38]  K. Hecht Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen , 1932 .

[39]  B. Pitt,et al.  Thallium-201 for myocardial imaging. Relation of thallium-201 to regional myocardial perfusion. , 1975, Circulation.

[40]  M. Ljungberg,et al.  A Monte Carlo program for the simulation of scintillation camera characteristics. , 1989, Computer methods and programs in biomedicine.

[41]  J. Humm,et al.  Accuracy and precision of radioactivity quantification in nuclear medicine images. , 2012, Seminars in nuclear medicine.

[42]  P Guerra,et al.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system , 2008, Physics in medicine and biology.

[43]  K. Bailey,et al.  Long-term outcome of patients with intermediate-risk exercise electrocardiograms who do not have myocardial perfusion defects on radionuclide imaging. , 1999, Circulation.