Diagonal Compression Testing of FRP-Retrofitted Unreinforced Clay Brick Masonry Wallettes

To address concerns regarding the seismic vulnerability of New Zealand unreinforced masonry (URM) buildings, a research program was undertaken to investigate the effectiveness of fiber-reinforced polymer (FRP) systems as a seismic retrofit intervention for in-plane loaded URM walls that are prone to fail in a shear mode during earthquakes. Seventeen URM wallettes were retrofitted with either externally bonded (EB) glass FRP fabrics, EB pultruded carbon FRP (CFRP) plates, or near-surface mounted pultruded CFRP rectangular bars. The wallettes were tested by the application of a diagonal compressive force, and data were recorded for applied force and corresponding wall drift. Results were compared with five nominally identical unretrofitted wallettes. It was determined that the FRP systems substantially increased the shear strength of the wallettes. Significant increases in the pseudoductility and the toughness were also obtained, which are all considered to be important goals of any seismic retrofit interve...

[1]  Pedro F. Silva,et al.  Monte Carlo Simulation of Shear Capacity of URM Walls Retrofitted by Polyurea Reinforced GFRP Grids , 2008 .

[2]  Pierino Lestuzzi,et al.  In-Plane Seismic Response of URM Walls Upgraded with FRP , 2005 .

[3]  T. Stratford,et al.  Shear Strengthening Masonry Panels with Sheet Glass-Fiber Reinforced Polymer , 2004 .

[4]  L. Megget,et al.  Bulletin of the New Zealand society for earthquake engineering , 2002 .

[5]  Antonio Nanni,et al.  Analysis of unreinforced masonry concrete walls strengthened with glass fiber-reinforced polymer bars , 2005 .

[6]  M. Elgaaly,et al.  Behavior of Composite Unreinforced Masonry–Fiber-Reinforced Polymer Wall Assemblages Under In-Plane Loading , 2005 .

[7]  David J. Dowrick Damage and intensities in the magnitude 7.8 1929 Murchison, New Zealand, earthquake , 1994 .

[8]  Maria Rosa Valluzzi,et al.  Flexural and shear strengthening of un-reinforced masonry with FRP bars , 2006 .

[9]  A. Prota,et al.  In-plane shear performance of masonry panels strengthened with FRP , 2007 .

[10]  Mark J. Masia,et al.  In-Plane Shear Behavior of Masonry Panels Strengthened with NSM CFRP Strips. I: Experimental Investigation , 2010 .

[11]  Jason Ingham,et al.  Prevalence of New Zealand’s unreinforced masonry buildings , 2010 .

[12]  Robert G. Drysdale,et al.  Masonry Structures: Behavior and Design , 1993 .

[13]  C. Modena,et al.  Shear behavior of masonry panels strengthened by FRP laminates , 2002 .

[14]  Steven C. Sweeney,et al.  Performance Testing of Fiber-Reinforced Polymer Composite Overlays for Seismic Rehabilitation of Unreinforced Masonry Walls , 2000 .

[15]  Arnold W. Hendry,et al.  Design of Masonry Structures , 2003 .

[16]  Alistair Russell,et al.  Characterisation and Seismic Assessment of Unreinforced Masonry Buildings , 2010 .

[17]  H R Hamilton,et al.  FLEXURAL CAPACITY OF GLASS FRP STRENGTHENED CONCRETE MASONRY WALLS , 2001 .

[18]  Gian Michele Calvi,et al.  In‐plane seismic response of brick masonry walls , 1997 .

[19]  Michel Bruneau,et al.  State-of-the-art report on seismic performance of unreinforced masonry buildings , 1995 .

[20]  T. Rossetto,et al.  Observations of damage due to the Kashmir earthquake of October 8, 2005 and study of current seismic provisions for buildings in Pakistan , 2009 .

[21]  Alaa E. Elwi,et al.  Cyclic Flexure Tests of Masonry Walls Reinforced with Glass Fiber Reinforced Polymer Sheets , 2003 .

[22]  P. Alcaíno,et al.  Experimental Response of Externally Retrofitted Masonry Walls Subjected to Shear Loading , 2008 .