Synergistic PET and SENSE MR Image Reconstruction Using Joint Sparsity Regularization

In this paper, we propose a generalized joint sparsity regularization prior and reconstruction framework for the synergistic reconstruction of positron emission tomography (PET) and under sampled sensitivity encoded magnetic resonance imaging data with the aim of improving image quality beyond that obtained through conventional independent reconstructions. The proposed prior improves upon the joint total variation (TV) using a non-convex potential function that assigns a relatively lower penalty for the PET and MR gradients, whose magnitudes are jointly large, thus permitting the preservation and formation of common boundaries irrespective of their relative orientation. The alternating direction method of multipliers (ADMM) optimization framework was exploited for the joint PET-MR image reconstruction. In this framework, the joint maximum a posteriori objective function was effectively optimized by alternating between well-established regularized PET and MR image reconstructions. Moreover, the dependency of the joint prior on the PET and MR signal intensities was addressed by a novel alternating scaling of the distribution of the gradient vectors. The proposed prior was compared with the separate TV and joint TV regularization methods using extensive simulation and real clinical data. In addition, the proposed joint prior was compared with the recently proposed linear parallel level sets (PLSs) method using a benchmark simulation data set. Our simulation and clinical data results demonstrated the improved quality of the synergistically reconstructed PET-MR images compared with the unregularized and conventional separately regularized methods. It was also found that the proposed prior can outperform both the joint TV and linear PLS regularization methods in assisting edge preservation and recovery of details, which are otherwise impaired by noise and aliasing artifacts. In conclusion, the proposed joint sparsity regularization within the presented a ADMM reconstruction framework is a promising technique, nonetheless our clinical results showed that the clinical applicability of joint reconstruction might be limited in current PET-MR scanners, mainly due to the lower resolution of PET images.

[1]  Stanley Osher,et al.  Vectorial non-local total variation regularization for calibration-free parallel MRI reconstruction , 2015, 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI).

[2]  David Atkinson,et al.  Joint reconstruction of PET-MRI by exploiting structural similarity , 2014, Inverse Problems.

[3]  Ciprian Catana,et al.  PET/MRI for Neurologic Applications , 2012, The Journal of Nuclear Medicine.

[4]  K. Lange Convergence of EM image reconstruction algorithms with Gibbs smoothing. , 1990, IEEE transactions on medical imaging.

[5]  P. Boesiger,et al.  Advances in sensitivity encoding with arbitrary k‐space trajectories , 2001, Magnetic resonance in medicine.

[6]  D. Louis Collins,et al.  Design and construction of a realistic digital brain phantom , 1998, IEEE Transactions on Medical Imaging.

[7]  R. Leahy,et al.  Magnetic resonance-guided positron emission tomography image reconstruction. , 2013, Seminars in nuclear medicine.

[8]  Kristian Bredies,et al.  Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer , 2017, IEEE Transactions on Medical Imaging.

[9]  D. Larkman,et al.  Parallel magnetic resonance imaging , 2007, Physics in medicine and biology.

[10]  D. Hunter,et al.  Optimization Transfer Using Surrogate Objective Functions , 2000 .

[11]  Michael Möller,et al.  Color Bregman TV , 2013, SIAM J. Imaging Sci..

[12]  Kieren Grant Hollingsworth,et al.  Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction , 2015, Physics in medicine and biology.

[13]  Kevin M. Holt,et al.  Total Nuclear Variation and Jacobian Extensions of Total Variation for Vector Fields , 2014, IEEE Transactions on Image Processing.

[14]  Jeffrey A. Fessler,et al.  Parallel MR Image Reconstruction Using Augmented Lagrangian Methods , 2011, IEEE Transactions on Medical Imaging.

[15]  Simon R. Arridge,et al.  PET Image Reconstruction Using Information Theoretic Anatomical Priors , 2011, IEEE Transactions on Medical Imaging.

[16]  Carola-Bibiane Schönlieb,et al.  Preconditioned ADMM with Nonlinear Operator Constraint , 2015, System Modelling and Optimization.

[17]  Ciprian Catana,et al.  Simultaneous PET-MRI in oncology: a solution looking for a problem? , 2012, Magnetic resonance imaging.

[18]  Chengbo Li An efficient algorithm for total variation regularization with applications to the single pixel camera and compressive sensing , 2010 .

[19]  Ben Adcock,et al.  Efficient Compressed Sensing SENSE pMRI Reconstruction With Joint Sparsity Promotion , 2016, IEEE Transactions on Medical Imaging.

[20]  Alvaro R. De Pierro,et al.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography , 1995, IEEE Trans. Medical Imaging.

[21]  David Atkinson,et al.  Incorporation of MRI-AIF information for improved kinetic modelling of dynamic PET data , 2015, IEEE Transactions on Nuclear Science.

[22]  Quanzheng Li,et al.  Magnetic resonance-based motion correction for positron emission tomography imaging. , 2013, Seminars in nuclear medicine.

[23]  G. Delso,et al.  Clinical Evaluation of Zero-Echo-Time MR Imaging for the Segmentation of the Skull , 2015, The Journal of Nuclear Medicine.

[24]  Stephen P. Boyd,et al.  Distributed Optimization and Statistical Learning via the Alternating Direction Method of Multipliers , 2011, Found. Trends Mach. Learn..

[25]  Andrew J. Reader,et al.  One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays , 2002 .

[26]  K. T. Block,et al.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint , 2007, Magnetic resonance in medicine.

[27]  Klaas Paul Pruessmann,et al.  Realistic Analytical Phantoms for Parallel Magnetic Resonance Imaging , 2012, IEEE Transactions on Medical Imaging.

[28]  D. O. Walsh,et al.  Adaptive reconstruction of phased array MR imagery , 2000, Magnetic resonance in medicine.

[29]  Patrick J La Rivière,et al.  Joint reconstruction of multi-channel, spectral CT data via constrained total nuclear variation minimization , 2014, Physics in medicine and biology.

[30]  Tony F. Chan,et al.  Color TV: total variation methods for restoration of vector-valued images , 1998, IEEE Trans. Image Process..

[31]  Cheng-Ying Chou,et al.  Alternating-direction method of multipliers estimation of attenuation and activity distributions in time-of-flight flat-panel positron emission tomography , 2015, EJNMMI Physics.

[32]  Armando Manduca,et al.  Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$ -Minimization , 2009, IEEE Transactions on Medical Imaging.