A capacitive humidity sensor with every fast response time and very low hysteresis

Abstract All polymer-based capactive sensors now on the market, in spite of a response time lower than 10 seconds for 63% deviation, require several hours before reaching a stable value. We show that, thanks to the use of novel polymers associated with electronic compensation, sensors exhibiting an accuracy better than 2% after only two minutes are feasible.