Thermo – lighting optimization proposal for school buildings in subtropical hot – humid climates: Monitoring and computer simulation on autumn period

Abstract The rate of glazed area to floor area and to sun-exposed wall area of a room is one of the main relationships in energetically optimized architecture. This paper shows the results of the hygrothermal and lighting behaviour on autumn period, of a Primary School which was monitored for a year. It was selected from a universe of 60 school prototypes located in Resistencia, a hot-humid mid-latitude city in the Northeast of Argentina. The measurements were compared with simulations through Simedif, Ecotect and its Radiance interface, in real occupation conditions. A root mean square error of 0.6 °C was obtained. Then the thermal behaviour of the building with an optimized envelope by regulating its glazed areas was simulated for the same period of autumn. Better hygrothermal comfort conditions were verified with the optimization proposal, as well as higher levels of illuminance and uniformity in the spatial distribution of natural light, which would be reflected in an electrical consumption saving for lighting. Consequently, this study will contribute to determining criteria for sizing suitably glazed areas to achieve wellness conditions, which are not covered in full in the current Planning and Building Codes, for school buildings in Resistencia.

[1]  Jonathan A. Wright,et al.  Geometric optimization of fenestration , 2009 .

[2]  Andrea Elvira Pattini,et al.  Effects of perceived indoor temperature on daylight glare perception , 2016 .

[3]  P Pieter-Jan Hoes,et al.  User behavior in whole building simulation , 2009 .

[4]  Ann R. Webb,et al.  Considerations for lighting in the built environment: Non-visual effects of light , 2006 .

[5]  Mohammad S. Al-Homoud Envelope Thermal Design Optimization of Buildings with Intermittent Occupancy , 2009 .

[6]  Michela Buzzetti,et al.  Energy Saving Through the Sun: Analysis of Visual Comfort and Energy Consumption in Office Space☆ , 2012 .

[7]  Qingyan Chen,et al.  Experimental and Simulation Study on the Performance of Daylighting in an Industrial Building and its Energy Saving Potential , 2014 .

[8]  Tony Roskilly,et al.  This Work Is Licensed under a Creative Commons Attribution 4.0 International License Royapoor M, Roskilly T. Building Model Calibration Using Energy and Environmental Data. Energy and Buildings Building Model Calibration Using Energy and Environmental Data Keywords: Model Calibration Measured Energy , 2022 .

[9]  Christoph F. Reinhart,et al.  The simulation of annual daylight illuminance distributions — a state-of-the-art comparison of six RADIANCE-based methods , 2000 .

[10]  Andrea Elvira Pattini,et al.  Use of low-cost daylighting system: custom design and application consequences in an office environment , 2011 .

[11]  P. Littlefair Passive solar urban design: ensuring the penetration of solar energy into the city , 1998 .

[12]  S. Flores Larsen,et al.  Response of conventional and energy-saving buildings to design and human dependent factors , 2005 .

[13]  Jianlei Niu,et al.  Optimal building envelope design based on simulated performance: History, current status and new potentials , 2016 .

[14]  Aris Tsangrassoulis,et al.  Dynamic operation of daylighting and shading systems: A literature review , 2016 .

[15]  Enedir Ghisi,et al.  An Ideal Window Area concept for energy efficient integration of daylight and artificial light in buildings , 2005 .

[16]  Gregory J. Ward,et al.  The RADIANCE lighting simulation and rendering system , 1994, SIGGRAPH.

[17]  Norhayati Mahyuddin,et al.  A review on natural ventilation applications through building façade components and ventilation openings in tropical climates , 2015 .

[18]  S. Flores Larsen,et al.  An experience on integrating monitoring and simulation tools in the design of energy-saving buildings , 2008 .

[19]  Jan L.M. Hensen,et al.  State of the art in lighting simulation for building science: a literature review , 2012 .

[20]  John Mardaljevic,et al.  Validation of a lighting simulation program under real sky conditions , 1995 .