Intensity modulation with the "step and shoot" technique using a commercial MLC: a planning study. Multileaf collimator.

PURPOSE/OBJECTIVE For complex planning situations where organs at risk (OAR) surrounding the target volume place stringent constraints, intensity-modulated treatments with photons provide a promising solution to improve tumor control and/or reduce side effects. One approach for the clinical implementation of intensity-modulated treatments is the use of a multileaf collimator (MLC) in the "step and shoot" mode, in which multiple subfields are superimposed for each beam direction to generate stratified intensity distributions with a discrete number of intensity levels. In this paper, we examine the interrelation between the number of intensity levels per beam for various numbers of beams, the conformity of the resulting dose distribution, and the treatment time on a commercial accelerator (Siemens Mevatron KD2) with built-in MLC. METHODS AND MATERIALS Two typical, clinically relevant cases of patients with head and neck tumors were selected for this study. Using the inverse planning technique, optimized treatment plans are generated for 3-25 evenly distributed coplanar beams as well as noncoplanar beams. An iterative gradient method is used to optimize a physical treatment objective that is based on the specified target dose and individual dose constraints assigned to each organ at risk (brain stem, eyes, optic nerves) by the radiation oncologist. The intensity distribution of each beam is discretized within the inverse planning program into three to infinitely many intensity levels or strata. These stratified intensity distributions are converted into MLC leaf position sequences, which can be subsequently transferred via computer link to the linac console, and can be delivered without user intervention. The quality of the plan is determined by comparing the values of the objective function, dose-volume histograms (DVHs), and isodose distributions. RESULTS Highly conformal dose distributions can be achieved with five intensity levels in each of seven beams. The merit of using more intensity levels or more beams is relatively small. Acceptable results are achievable even with three levels only. On average, the number of subfields per beam is about 2-2.5 times the number of intensity levels. The average treatment time per subfield is about 20 s. The total treatment time for the three-level and seven-beam case with a total of 39 subfields is 13 min. CONCLUSION Optimizing stratified intensity distributions in the inverse planning process allows us to achieve close to optimum results with a surprisingly small number of intensity levels. This finding may help to facilitate and accelerate the delivery of intensity-modulated treatments with the "step and shoot" technique.

[1]  J. V. van Santvoort,et al.  Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects. , 1996, Physics in medicine and biology.

[2]  A. Cormack,et al.  A problem in rotation therapy with X rays. , 1987, International journal of radiation oncology, biology, physics.

[3]  S Webb,et al.  The effect of stair-step leaf transmission on the 'tongue-and-groove problem' in dynamic radiotherapy with a multileaf collimator. , 1997, Physics in medicine and biology.

[4]  S. Webb Optimization by simulated annealing of three-dimensional conformal treatment planning for radiation fields defined by a multileaf collimator. , 1991, Physics in medicine and biology.

[5]  R Mohan,et al.  Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation. , 1996, International journal of radiation oncology, biology, physics.

[6]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[7]  C De Wagter,et al.  Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed with a multileaf collimator. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  W Schlegel,et al.  Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  A. Brahme,et al.  A generalized pencil beam algorithm for optimization of radiation therapy. , 1994, Medical physics.

[10]  T. Bortfeld,et al.  Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning. , 1993, Medical physics.

[11]  M. Martel,et al.  Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: assessment of target coverage and noninvolved tissue sparing. , 1998, International journal of radiation oncology, biology, physics.

[12]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[13]  W. De Gersem,et al.  Conformal radiotherapy of Stage III non-small cell lung cancer: a class solution involving non-coplanar intensity-modulated beams. , 1998, International journal of radiation oncology, biology, physics.