Frequency dependence of attenuation and backscatter coefficient of ex vivo human lymphedema dermis

Purpose Radio-frequency (RF) signals from the most dominant scatterer in a dermis, i.e., collagen fibers, are collected as backscattered signals. We aim to confirm the frequency dependence of the spatial distribution of features in ultrasound images, as well as the attenuation coefficient (AC) and backscatter coefficient (BSC) of skin tissue without [LE (−)] and with lymphedema [LE (+)]. Methods Measurement samples ( n  = 13) were excised from human skin tissue with LE (−) and middle severity LE (+). A laboratory-made scanner and single-element concave transducers (range 9–47 MHz) were used to measure RF data. A localized AC was computed from the normalized power spectrum using the linear least squares technique. The reflector method and compensation technique of the attenuation of tissue were applied to calculate the BSC. In addition, effective scatterer diameter (ESD), effective acoustic concentration (EAC), and integrated BSC (IBS) were calculated from the BSC as the benchmark to differentiate LE (−) and LE (+) tissues. Results High-frequency ultrasound displayed different echogenicity and texture compared between LE (−) and LE (+) in all transducers. The AC for LE (−) (0.22 dB/mm/MHz) and LE (+) (0.29 dB/mm/MHz) was comparable. BSC in LE (−) and LE (+) increased linearly with each transducer. The difference of intercept of the BSC between LE (−) and LE (+) indicated that both EAC and IBS of LE (+) were higher than that of LE (−). In contrast, ESD correlated with the slope of the BSC demonstrated the same tendency for both LE (−) and LE (+). These tendencies appeared for each transducer independent of the frequency bandwidth. Conclusion Frequency independence of AC and BSC in LE (−) and LE (+) was confirmed. Several 9- to 19-MHz ultrasound beams are sufficient for BSC analysis to discriminate LE (−) and LE (+) in terms of the penetration depth of the ultrasound.

[1]  K. Hamano,et al.  Subcutaneous tissue ultrasonography in legs with dependent edema and secondary lymphedema. , 2014, Annals of vascular diseases.

[2]  William D O'Brien,et al.  Characterization of tissue microstructure using ultrasonic backscatter: theory and technique for optimization using a Gaussian form factor. , 2002, The Journal of the Acoustical Society of America.

[3]  R. Meijer,et al.  Characterisation of Anisotropic and Non-linear Behaviour of Human Skin In Vivo. , 1999, Computer methods in biomechanics and biomedical engineering.

[4]  M. Berson,et al.  In vivo high-frequency ultrasonic characterization of human dermis , 1999, IEEE Transactions on Biomedical Engineering.

[5]  Kazutoshi Kumagai,et al.  High-resolution ultrasound imaging of human skin in vivo by using three-dimensional ultrasound microscopy. , 2012, Ultrasound in medicine & biology.

[6]  Goutam Ghoshal,et al.  On the estimation of backscatter coefficients using single-element focused transducers. , 2011, The Journal of the Acoustical Society of America.

[7]  K. Hamano,et al.  Correlation Between the Severity of Subcutaneous Echo-Free Space and the Amount of Extracellular Fluid Determined by Bioelectrical Impedance Analysis of Leg Edema. , 2017, Lymphatic research and biology.

[8]  S. L. Bridal,et al.  Ultrasonic Backscatter and Attenuation (11–27 MHz) Variation with Collagen Fiber Distribution in Ex Vivo Human Dermis , 2006, Ultrasonic imaging.

[9]  S. Miyamoto,et al.  Pathological changes of adipose tissue in secondary lymphoedema , 2017, The British journal of dermatology.

[10]  Shinsuke Akita,et al.  Comparison of lymphoscintigraphy and indocyanine green lymphography for the diagnosis of extremity lymphoedema. , 2013, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[11]  A. Mitsuhashi,et al.  Early Diagnosis and Risk Factors for Lymphedema following Lymph Node Dissection for Gynecologic Cancer , 2013, Plastic and reconstructive surgery.

[12]  Hassan Rivaz,et al.  Low Variance Estimation of Backscatter Quantitative Ultrasound Parameters Using Dynamic Programming , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[13]  Salvador Gonzalez,et al.  Quantitative ultrasonic methods for characterization of skin lesions in vivo. , 2003, Ultrasound in medicine & biology.

[14]  J. G. Mottley,et al.  The measurement of backscatter coefficient from a broadband pulse-echo system: a new formulation , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Development of a mouse model for the visual and quantitative assessment of lymphatic trafficking and function by in vivo imaging , 2018, Scientific Reports.

[16]  R. Bard,et al.  Ultrasound in dermatology: principles and applications. , 2012, Journal of the American Academy of Dermatology.

[17]  M. Srinivasan,et al.  Statistics of envelope of high-frequency ultrasonic backscatter from human skin in vivo , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  Shinsuke Akita,et al.  Verification of echo amplitude envelope analysis method in skin tissues for quantitative follow-up of healing ulcers , 2018, Japanese Journal of Applied Physics.

[19]  Régine Guillermin,et al.  Experimental assessment of four ultrasound scattering models for characterizing concentrated tissue-mimicking phantoms. , 2012, The Journal of the Acoustical Society of America.

[20]  M A Srinivasan,et al.  High-frequency ultrasonic attenuation and backscatter coefficients of in vivo normal human dermis and subcutaneous fat. , 2001, Ultrasound in medicine & biology.

[21]  S. L. Bridal,et al.  Reproducibility of skin characterization with backscattered spectra (12--25 MHz) in healthy subjects. , 2001, Ultrasound in medicine & biology.

[22]  J C Bamber,et al.  Ultrasonic propagation properties of excised human skin. , 1995, Ultrasound in medicine & biology.

[23]  Roberto Lavarello,et al.  Regularized Spectral Log Difference Technique for Ultrasonic Attenuation Imaging , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[24]  William D O'Brien,et al.  Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media. , 2002, The Journal of the Acoustical Society of America.

[25]  Shyh-Hau Wang,et al.  In vivo assessment of inflammatory skin using high frequency ultrasound image and quantitative parameters , 2010, 2010 IEEE International Ultrasonics Symposium.