Fast and robust reconstruction for fluorescence molecular tomography via a sparsity adaptive subspace pursuit method.

Fluorescence molecular tomography (FMT), as a promising imaging modality, can three-dimensionally locate the specific tumor position in small animals. However, it remains challenging for effective and robust reconstruction of fluorescent probe distribution in animals. In this paper, we present a novel method based on sparsity adaptive subspace pursuit (SASP) for FMT reconstruction. Some innovative strategies including subspace projection, the bottom-up sparsity adaptive approach, and backtracking technique are associated with the SASP method, which guarantees the accuracy, efficiency, and robustness for FMT reconstruction. Three numerical experiments based on a mouse-mimicking heterogeneous phantom have been performed to validate the feasibility of the SASP method. The results show that the proposed SASP method can achieve satisfactory source localization with a bias less than 1mm; the efficiency of the method is much faster than mainstream reconstruction methods; and this approach is robust even under quite ill-posed condition. Furthermore, we have applied this method to an in vivo mouse model, and the results demonstrate the feasibility of the practical FMT application with the SASP method.

[1]  V. Ntziachristos Fluorescence molecular imaging. , 2006, Annual review of biomedical engineering.

[2]  Ge Wang,et al.  A finite-element-based reconstruction method for 3D fluorescence tomography. , 2005, Optics express.

[3]  Jie Tian,et al.  Efficient reconstruction method for L1 regularization in fluorescence molecular tomography. , 2010, Applied optics.

[4]  Michael Elad,et al.  Coordinate and subspace optimization methods for linear least squares with non-quadratic regularization , 2007 .

[5]  V. Ntziachristos Going deeper than microscopy: the optical imaging frontier in biology , 2010, Nature Methods.

[6]  Zhao Hui-juan A Linear Featured-data Scheme for Image Reconstruction in Time-domain Fluorescence Molecular Tomography , 2008 .

[7]  Edward W. Larsen,et al.  Light transport in biological tissue based on the simplified spherical harmonics equations , 2006, J. Comput. Phys..

[8]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[9]  Jing Bai,et al.  Adaptive-mesh-based algorithm for fluorescence molecular tomography using an analytical solution. , 2007, Optics express.

[10]  V. Ntziachristos,et al.  FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography–X-ray computed tomography , 2012, Nature Methods.

[11]  A. Chatziioannou,et al.  Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study , 2005, Physics in medicine and biology.

[12]  Beth Friedman,et al.  Fluorescent peptides highlight peripheral nerves during surgery in mice , 2011, Nature Biotechnology.

[13]  Jie Tian,et al.  Fast cone-beam CT image reconstruction using GPU hardware , 2008 .

[14]  P. Low,et al.  Intraoperative tumor-specific fluorescence imaging in ovarian cancer by folate receptor-α targeting: first in-human results , 2011, Nature Medicine.

[15]  Jie Tian,et al.  New optical molecular imaging systems. , 2010, Current pharmaceutical biotechnology.

[16]  Nathan Blow In vivo molecular imaging: the inside job , 2009, Nature Methods.

[17]  Vasilis Ntziachristos,et al.  The inverse source problem based on the radiative transfer equation in optical molecular imaging , 2005 .

[18]  Sanjiv S Gambhir,et al.  Noninvasive molecular imaging of c-Myc activation in living mice , 2010, Proceedings of the National Academy of Sciences.

[19]  Arye Nehorai,et al.  Image reconstruction for diffuse optical tomography using sparsity regularization and expectation-maximization algorithm. , 2007, Optics express.

[20]  Wolfgang Bangerth,et al.  Adaptive finite element methods for the solution of inverse problems in optical tomography , 2008 .

[21]  Jie Tian,et al.  Detection of mouse liver cancer via a parallel iterative shrinkage method in hybrid optical/microcomputed tomography imaging , 2012, Journal of biomedical optics.

[22]  Nanguang Chen,et al.  Reconstruction for free-space fluorescence tomography using a novel hybrid adaptive finite element algorithm. , 2007, Optics express.

[23]  Jie Tian,et al.  A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. , 2010, Optics express.

[24]  Jae Hoon Lee,et al.  Fully adaptive finite element based tomography using tetrahedral dual-meshing for fluorescence enhanced optical imaging in tissue. , 2007, Optics express.

[25]  Yuting Lin,et al.  Fluorescence diffuse optical tomography with functional and anatomical a priori information: feasibility study , 2007, Physics in medicine and biology.

[26]  David L Donoho,et al.  Compressed sensing , 2006, IEEE Transactions on Information Theory.

[27]  Dong Han,et al.  Sparsity-Promoting Tomographic Fluorescence Imaging With Simplified Spherical Harmonics Approximation , 2010, IEEE Transactions on Biomedical Engineering.

[28]  Jie Tian,et al.  Cone Beam Micro-CT System for Small Animal Imaging and Performance Evaluation , 2009, Int. J. Biomed. Imaging.

[29]  Michael Elad,et al.  From Sparse Solutions of Systems of Equations to Sparse Modeling of Signals and Images , 2009, SIAM Rev..

[30]  A. Joshi,et al.  Adaptive finite element based tomography for fluorescence optical imaging in tissue. , 2004, Optics express.

[31]  Geoffrey McLennan,et al.  Practical reconstruction method for bioluminescence tomography. , 2005, Optics express.

[32]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[33]  Ge Wang,et al.  A finite-element-based reconstruction method for 3 D fluorescence tomography , 2005 .

[34]  Hua-bei Jiang,et al.  DOT guided fluorescence molecular tomography of arbitrarily shaped objects. , 2008, Medical physics.

[35]  Xin Liu,et al.  A Novel Finite-Element-Based Algorithm for Fluorescence Molecular Tomography of Heterogeneous Media , 2009, IEEE Transactions on Information Technology in Biomedicine.

[36]  Xiaochao Qu,et al.  3D reconstruction of light flux distribution on arbitrary surfaces from 2D multi-photographic images. , 2010, Optics express.

[37]  David A Boas,et al.  Fluorescence optical diffusion tomography using multiple-frequency data. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[38]  Feng Gao,et al.  A linear, featured-data scheme for image reconstruction in time-domain fluorescence molecular tomography. , 2006, Optics express.

[39]  A. Adibi,et al.  Optimal sparse solution for fluorescent diffuse optical tomography: theory and phantom experimental results. , 2007, Applied optics.