Three-Dimensional Transcranial Ultrasound Imaging of Microbubble Clouds Using a Sparse Hemispherical Array

There is an increasing interest in bubble-mediated focused ultrasound (FUS) interventions in the brain. However, current technology lacks the ability to spatially monitor the interaction of the microbubbles with the applied acoustic field, something which is critical for safe clinical translation of these treatments. Passive acoustic mapping could offer a means for spatially monitoring microbubble emissions that relate to bubble activity and associated bioeffects. In this study, a hemispherical receiver array was integrated within an existing transcranial therapy array to create a device capable of both delivering therapy and monitoring the process via passive imaging of bubble clouds. A 128-element receiver array was constructed and characterized for varying bubble concentrations and source spacings. Initial in vivo feasibility testing was performed. The system was found to be capable of monitoring bubble emissions down to single bubble events through an ex vivo human skull. The lateral resolution of the system was found to be between 1.25 and 2 mm and the axial resolution between 2 and 3.5 mm, comparable to the resolution of MRI-based temperature monitoring during thermal FUS treatments in the brain. The results of initial in vivo experiments show that bubble activity can be mapped starting at pressure levels below the threshold for blood-brain barrier disruption. This study presents a feasible solution for imaging bubble activity during cavitation-mediated FUS treatments in the brain.

[1]  Mu-Yi Hua,et al.  Novel magnetic/ultrasound focusing system enhances nanoparticle drug delivery for glioma treatment. , 2010, Neuro-oncology.

[2]  Vasant A Salgaonkar,et al.  Passive cavitation imaging with ultrasound arrays. , 2009, The Journal of the Acoustical Society of America.

[3]  B. D. Lindsey,et al.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Ronald A. Roy,et al.  Thresholds for cavitation produced in water by pulsed ultrasound. , 1988, Ultrasonics.

[5]  K. Nightingale,et al.  Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in Mice. , 2009, Ultrasound in medicine & biology.

[6]  F A Jolesz,et al.  Potential adverse effects of high-intensity focused ultrasound exposure on blood vessels in vivo. , 1996, Ultrasound in medicine & biology.

[7]  Ronald A. Roy,et al.  An acoustic backscattering technique for the detection of transient cavitation produced by microsecond pulses of ultrasound. , 1990, The Journal of the Acoustical Society of America.

[8]  K. Hynynen,et al.  MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study , 2013, The Lancet Neurology.

[9]  K. Hynynen,et al.  High-Intensity Focused Ultrasound (HIFU) for Dissolution of Clots in a Rabbit Model of Embolic Stroke , 2012, PloS one.

[10]  K. Hynynen,et al.  Focused-ultrasound disruption of the blood-brain barrier using closely-timed short pulses: influence of sonication parameters and injection rate. , 2011, Ultrasound in medicine & biology.

[11]  Miklós Gyöngy,et al.  Passive Spatial Mapping of Inertial Cavitation During HIFU Exposure , 2010, IEEE Transactions on Biomedical Engineering.

[12]  Kullervo Hynynen,et al.  Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study , 2013, Physics in medicine and biology.

[13]  T. D. Mast,et al.  Passive imaging with pulsed ultrasound insonations. , 2012, The Journal of the Acoustical Society of America.

[14]  Tom Leslie,et al.  Spatiotemporal monitoring of high-intensity focused ultrasound therapy with passive acoustic mapping. , 2012, Radiology.

[15]  Takuso Sato,et al.  Super‐resolution acoustical passive imaging system using algebraic reconstruction , 1980 .

[16]  M Tanter,et al.  Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans. , 2003, The Journal of the Acoustical Society of America.

[17]  Ronald A. Roy,et al.  Temporal and spatial detection of HIFU-induced inertial and hot-vapor cavitation with a diagnostic ultrasound system. , 2009, Ultrasound in medicine & biology.

[18]  Margaret S Livingstone,et al.  Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain , 2013, Physics in medicine and biology.

[19]  Dalong Liu,et al.  Real-time implementation of a dual-mode ultrasound array system: In vivo results , 2012, 2012 IEEE International Ultrasonics Symposium.

[20]  Stephen W. Smith,et al.  The ultrasound brain helmet: early human feasibility study of multiple simultaneous 3D scans of cerebral vasculature , 2009, Medical Imaging.

[21]  K. Hynynen,et al.  Transcranial Magnetic Resonance Imaging– Guided Focused Ultrasound Surgery of Brain Tumors: Initial Findings in 3 Patients , 2010, Neurosurgery.

[22]  Stephen J. Norton,et al.  Backprojection reconstruction of random source distributions , 1987 .

[23]  K. Hynynen,et al.  Targeted disruption of the blood–brain barrier with focused ultrasound: association with cavitation activity , 2006, Physics in medicine and biology.

[24]  Kullervo Hynynen,et al.  Blood-brain barrier: real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller. , 2012, Radiology.

[25]  Stephen J. Norton,et al.  Time exposure acoustics , 2000, IEEE Trans. Geosci. Remote. Sens..

[26]  J-F Aubry,et al.  In vivo bubble nucleation probability in sheep brain tissue , 2011, Physics in medicine and biology.

[27]  G T Clement,et al.  A non-invasive method for focusing ultrasound through the human skull. , 2002, Physics in medicine and biology.

[28]  Elisa E Konofagou,et al.  Noninvasive and localized neuronal delivery using short ultrasonic pulses and microbubbles , 2011, Proceedings of the National Academy of Sciences.

[29]  Kullervo Hynynen,et al.  Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls , 2011, Physics in medicine and biology.

[30]  Ronald A. Roy,et al.  Acoustic microcavitation: its active and passive acoustic detection. , 1991, The Journal of the Acoustical Society of America.

[31]  R. Skinner,et al.  Successful Microbubble Sonothrombolysis Without Tissue-Type Plasminogen Activator in a Rabbit Model of Acute Ischemic Stroke , 2011, Stroke.

[32]  Natalia Vykhodtseva,et al.  Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: safety and efficacy evaluation in rhesus macaques. , 2012, Cancer research.

[33]  A. Morel,et al.  High‐intensity focused ultrasound for noninvasive functional neurosurgery , 2009, Annals of neurology.

[34]  Vesna Zderic,et al.  Hyperecho in ultrasound images of HIFU therapy: involvement of cavitation. , 2005, Ultrasound in medicine & biology.

[35]  F A Jolesz,et al.  Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. , 1998, Ultrasound in medicine & biology.

[36]  K. Hynynen,et al.  Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. , 2001, Radiology.

[37]  Emad S Ebbini,et al.  Dual-Mode Ultrasound Phased Arrays for Image-Guided Surgery , 2006, Ultrasonic imaging.

[38]  Junho Song,et al.  Feasibility of Using Lateral Mode Coupling Method for a Large Scale Ultrasound Phased Array for Noninvasive Transcranial Therapy , 2010, IEEE Transactions on Biomedical Engineering.

[39]  A. Hurrell,et al.  Thin-film sparse boundary array design for passive acoustic mapping during ultrasound therapy , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[40]  Stephan G. Wetzel,et al.  Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging , 2000, European Radiology.

[41]  Meaghan A. O'Reilly,et al.  A super-resolution ultrasound method for brain vascular mapping. , 2013, Medical physics.

[42]  M. Livingstone,et al.  Controlled Ultrasound-Induced Blood-Brain Barrier Disruption Using Passive Acoustic Emissions Monitoring , 2012, PloS one.

[43]  James J. Choi,et al.  Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. , 2007, Ultrasound in medicine & biology.