The energy efficiency ratio of heat storage in one shell-and-one tube phase change thermal energy storage unit

From aspect of energy consuming to pump heat transfer fluid, there is no sound basis on which to create an optimum design of a thermal energy storage unit. Thus, it is necessary to develop a parameter to indicate the energy efficiency of such unit. This paper firstly defines a parameter that indicates the ratio of heat storage of phase change thermal energy storage unit to energy consumed in pumping heat transfer fluid, which is called the energy efficiency ratio, then numerically investigates the characteristics of this parameter. The results show that the energy efficiency ratio can clearly indicate the energy efficiency of a phase change thermal energy storage unit. When the fluid flow of a heat transfer fluid is in a laminar state, the energy efficiency ratio is larger than in a turbulent state. The energy efficiency ratio of a shell-and-tube phase change thermal energy storage unit is more sensitive to the outer tube diameter. Under the same working conditions, within the heat transfer fluids studied, the heat storage property of the phase change thermal energy storage unit is best for water as heat transfer fluid. A combined parameter is found to indicate the effects of both the physical properties of phase change material and heat transfer fluid on the energy efficiency ratio.

[1]  Luisa F. Cabeza,et al.  Review on thermal energy storage with phase change: materials, heat transfer analysis and applications , 2003 .

[2]  M. Lacroix Numerical simulation of a shell-and-tube latent heat thermal energy storage unit , 1993 .

[3]  Luisa F. Cabeza,et al.  Experimental analysis of the effectiveness of a high temperature thermal storage tank for solar cooling applications , 2013 .

[4]  Martin Belusko,et al.  Experimental validation of a CFD model for tubes in a phase change thermal energy storage system , 2012 .

[5]  Martin Belusko,et al.  An effectiveness-NTU technique for characterising a finned tubes PCM system using a CFD model , 2014 .

[6]  Ya-Ling He,et al.  A MCRT and FVM coupled simulation method for energy conversion process in parabolic trough solar collector , 2011 .

[7]  Martin Belusko,et al.  Effectiveness–NTU correlation for low temperature PCM encapsulated in spheres , 2012 .

[8]  V. Voller FAST IMPLICIT FINITE-DIFFERENCE METHOD FOR THE ANALYSIS OF PHASE CHANGE PROBLEMS , 1990 .

[9]  K. Kaygusuz,et al.  Experimental study on melting/solidification characteristics of a paraffin as PCM , 2007 .

[10]  Ming Fang,et al.  Effects of different multiple PCMs on the performance of a latent thermal energy storage system , 2007 .

[11]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[12]  Bernard Franković,et al.  Analysis of the influence of operating conditions and geometric parameters on heat transfer in water-paraffin shell-and-tube latent thermal energy storage unit , 2006 .

[13]  Martin Belusko,et al.  Experimental validation of a CFD and an ε-NTU model for a large tube-in-tank PCM system , 2012 .

[14]  F. Bruno,et al.  Effective thermal conductivity for melting in PCM encapsulated in a sphere , 2014 .

[15]  Francis Agyenim,et al.  A review of materials, heat transfer and phase change problem formulation for latent heat thermal energy storage systems (LHTESS) , 2010 .

[16]  Jinyue Yan,et al.  Enhanced thermal conductivity and thermal performance of form-stable composite phase change materials by using β-Aluminum nitride , 2009 .

[17]  Wang Weiwei,et al.  Optimization of solar-powered Stirling heat engine with finite-time thermodynamics , 2011 .

[18]  Ya-Ling He,et al.  A new modelling method and unified code with MCRT for concentrating solar collectors and its applications , 2013 .

[19]  M. Farid,et al.  Thermal Performance of a Heat Storage Module Using PCM’s With Different Melting Temperatures: Mathematical Modeling , 1989 .

[20]  J. M. Coulson,et al.  Heat Transfer , 2018, Heat Transfer in Food Cooling Applications.

[21]  A. Sharma,et al.  Review on thermal energy storage with phase change materials and applications , 2009 .

[22]  Anica Trp,et al.  An experimental and numerical investigation of heat transfer during technical grade paraffin melting and solidification in a shell-and-tube latent thermal energy storage unit , 2005 .

[23]  Ya-Ling He,et al.  Numerical study on thermal energy storage performance of phase change material under non-steady-state inlet boundary , 2011 .

[24]  Hamid Ait Adine,et al.  Numerical analysis of the thermal behaviour of a shell-and-tube heat storage unit using phase change materials , 2009 .

[25]  Kamaruzzaman Sopian,et al.  Review of thermal energy storage for air conditioning systems , 2012 .

[26]  Liang-Bi Wang,et al.  Numerical study of the heat charging and discharging characteristics of a shell-and-tube phase change heat storage unit , 2013 .

[27]  Ya-Ling He,et al.  Numerical study on coupling phase change heat transfer performance of solar dish collector , 2013 .

[28]  Ya-Ling He,et al.  Numerical study on performance of molten salt phase change thermal energy storage system with enhanced tubes , 2012 .

[29]  S. Garimella,et al.  Molten-salt thermal energy storage in thermoclines under different environmental boundary conditions , 2010 .

[30]  Martin Belusko,et al.  An effectiveness-NTU technique for characterising tube-in-tank phase change thermal energy storage systems , 2012 .

[31]  Kamil Kaygusuz,et al.  Thermal energy storage performance of paraffin in a novel tube-in-shell system , 2008 .

[32]  L. Cabeza,et al.  Experimental evaluation of commercial heat exchangers for use as PCM thermal storage systems , 2009 .