Impedance-based fault location in transmission networks: theory and application

A number of impedance-based fault location algorithms have been developed for estimating the distance to faults in a transmission network. Each algorithm has specific input data requirements and makes certain assumptions that may or may not hold true in a particular fault location scenario. Without a detailed understanding of the principle of each fault-locating method, choosing the most suitable fault location algorithm can be a challenging task. This paper, therefore, presents the theory of one-ended (simple reactance, Takagi, modified Takagi, Eriksson, and Novosel et al.) and two-ended (synchronized, unsynchronized, and current-only) impedance-based fault location algorithms and demonstrates their application in locating real-world faults. The theory details the formulation and input data requirement of each fault-locating algorithm and evaluates the sensitivity of each to the following error sources: 1) load; 2) remote infeed; 3) fault resistance; 4) mutual coupling; 5) inaccurate line impedances; 6) DC offset and CT saturation; 7) three-terminal lines; and 8) tapped radial lines. From the theoretical analysis and field data testing, the following criteria are recommended for choosing the most suitable fault-locating algorithm: 1) data availability and 2) fault location application scenario. Another objective of this paper is to assess what additional information can be gleaned from waveforms recorded by intelligent electronic devices (IEDs) during a fault. Actual fault event data captured in utility networks is exploited to gain valuable feedback about the transmission network upstream from the IED device, and estimate the value of fault resistance.

[1]  Joaquim Melendez,et al.  Comparison of impedance based fault location methods for power distribution systems , 2008 .

[2]  A.L. Dalcastagne,et al.  A study about the sources of error of impedance-based fault location methods , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America.

[3]  D. A. Tziouvaras,et al.  New multi-ended fault location design for two- or three-terminal lines , 2001 .

[4]  D. Costello,et al.  Impedance-Based Fault Location Experience , 2006, 2006 IEEE Rural Electric Power Conference.

[5]  Hashim Hizam,et al.  Review of fault location methods for distribution power system , 2009 .

[6]  Murari Mohan Saha,et al.  REVIEW OF FAULT LOCATION TECHNIQUES FOR DISTRIBUTION SYSTEMS , 2002 .

[7]  W. Marsden I and J , 2012 .

[8]  S. Richards,et al.  Protection of Double Circuit Transmission Lines , 2007, 2007 60th Annual Conference for Protective Relay Engineers.

[9]  Rastko Zivanovic Evaluation of transmission line fault-locating techniques using variance-based sensitivity measures , 2008 .

[10]  Hew Wooi Ping,et al.  Impedance-based fault location techniques for transmission lines , 2009, TENCON 2009 - 2009 IEEE Region 10 Conference.

[11]  William Kersting,et al.  Distribution System Modeling and Analysis , 2001, Electric Power Generation, Transmission, and Distribution: The Electric Power Engineering Handbook.

[12]  T. Takagi,et al.  Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data , 1982, IEEE Power Engineering Review.

[13]  M. Kezunovic,et al.  A Systematic Approach for Ranking Distribution Systems Fault Location Algorithms and Eliminating False Estimates , 2013, IEEE Transactions on Power Delivery.

[14]  Surya Santoso,et al.  Feature analysis and classification methodology for overhead distribution fault events , 2010, IEEE PES General Meeting.

[15]  Eugeniusz Rosolowski,et al.  Fault Location on Power Networks , 2009 .

[16]  A. Amberg,et al.  Validating transmission line impedances using known event data , 2012, 2012 65th Annual Conference for Protective Relay Engineers.

[17]  Edmond O. Schweitzer Evaluation and development of transmission line fault-locating techniques which use sinusoidal steady-state information , 1983 .

[18]  H.H. El-Tamaly,et al.  Sequence Impedances of Overhead Transmission Lines Carson's Method Versus Rudenberg's Method , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[19]  Murari Mohan Saha,et al.  An Accurate Fault Locator with Compensation for Apparent Reactance in the Fault Resistance Resulting from Remote-End Infeed , 1985, IEEE Power Engineering Review.